Elite Networking
2Pages

{{requestButtons}}

Catalog excerpts

Elite Networking - 1

Elite Networking: VF1170-00 Standard Features - Up to 64 nodes - High integrity protocol when wired Class A - Fully secure against short or open circuit faults - Simple 2-wire loop connection - Supports open ended networks for retrofit applications - Network wide test and disablement functions - Network wide cause and effect logic - Flexible configurations options - Panels configurable to act on network events or not as required USCG Type Approved 161.002/A53/0 Product Overview - The flexibility of the Elite system can be further enhanced by connecting control panels and repeaters together using a high integrity network. - A simple 2-wire connection between each panel allows events to be transmitted to other parts of the system to provide indication or control on a system wide basis. - Using the Loop Explorer configuration software, up to 64 nodes can be programmed to respond in a variety of ways to any system events as required. - This flexibility extends the comprehensive cause and effect programming capability of Elite control panels to the entire network allowing actions, test modes or disablements to be started from any point. - The fault tolerance of the network is such that any single open or short circuit fault will not result in any loss of information. Multiple faults are isolated and the network breaks into smaller networks which continue to work autonomously. Fireboy-Xintex, Inc. O-379 Lake Michigan Drive Grand Rapids, MI 49534 . 616.735.9380 Fireboy-Xintex, Ltd Unit 10 Holton Road, Holton Industrial Estate Poole, Dorset BH166LT UK . 44 (0) 845 389 9462

Open the catalog to page 1
Elite Networking - 2

Two conductor loop wiring ensures network integrity by providing full isolation of faulty wiring segments. Elite Control Panel Flexible network configuration using simple to follow PC configuration software Configure Panel Settings r>F3 paid wfy i«C"X-J (c Ttrt -J-«t« r^rt. tppKf ion otfw etrtb v-\*< ~**.>~j\ Elite Control Panel Technical Specifications Connection: Two wire loop Integrity: Full isolation of faulty nodes or wiring segments Indicators: Data In and Data Out communications status Cable length: 3900ft to adjacent nodes (subject to cable type) Cable type: Belden 9271, Belden...

Open the catalog to page 2

All Fireboy - Xintex catalogs and brochures

  1. Isolator

    1 Pages

  2. fire alarm

    2 Pages

  3. Elite RS-M

    2 Pages

Archived catalogs

  1. GA Series

    2 Pages