CARBON MONOXIDE DETECTOR Installation and Operation Manual IMPORTANT: READ THIS MANUAL CAREFULLY, SAVE FOR FUTURE REFERENCE. KEEP THIS MANUAL WITH THE CMD-3M. There are no user or field serviceable parts in this product. The CMD-3M must be returned to the manufacturer for any repair or performance checks. Installation shall be done by qualified personnel authorized to do so by the authorities having jurisdiction for the particular application in which the product is being used. Electrical wiring shall be in accordance with applicable codes. Improper wiring may render the unit inoperable, damage components, or cause a fire, and will void The CMD-3M is a carbon monoxide detector only. It will not detect smoke, smoldering fires, or combustible fumes. To function as intended, CMD-3M must be connected to a correct power source, and for maximum effectiveness, be powered at all times. Do not install outdoors. Before installing in applications which may appear different than those outlined in this manual, consult the engineering department of Fireboy-Xintex Inc. Not for use in aircraft. FIREBOY-XINTEX INC. SAFETY SYSTEMS Mailing Address: P.O. Box 152, Grand Rapids, Michigan USA 49501-0152 Shipping: 0-379 Lake Michigan Drive NW, Grand Rapids, Michigan USA 49544 Website: www.fireboy-xintex.com E-mail: fireboy@fireboy-xintex.com
Open the catalog to page 1CMD-3M Carbon Monoxide Detector This device shall not be installed or used in aircraft and or racing voUictos. Fireboy/Xintex reserves the right to change features without notico
Open the catalog to page 2Location of Alarms, Indicators, and Test Switch TEST BUTTON DANGER INDICATOR WARNING: Actuation of this device indicates the presence of carbon monoxide (CO) which can be FATAL. The source of the CO may be an appliance such as a furnace, a wood burning stove, a vehicle, or other combustion source. EVACUATE THE PREMISES IMMEDIATELY. DO A HEAD COUNT TO CHECK THAT ALL PERSONS ARE ACCOUNTED FOR. CALL THE NEAREST FIRE DEPARTMENT AND ASK THEM TO DETERMINE THE SOURCE OF CARBON MONOXIDE. DO NOT REENTER PREMISES UNTIL IT HAS BEEN AIRED OUT AND THE ^k. CAUTION: This detector will only indicate the...
Open the catalog to page 3CMD-3M Carbon Monoxide Detector a. Mild exposure: Slight headache, nausea, vomiting, fatigue (often described as "Flu like" symptoms). b. Medium exposure: Severe throbbing headache, drowsiness, confusion, and fast heart rate. c. Extreme exposure: Unconsciousness, convulsions, cardio respiratory failure, death. d. Many cases of reported CARBON MONOXIDE POISONING indicate that while victims are aware they are not well, they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance. Also young children and household pets may be the first...
Open the catalog to page 4Drug or alcohol use increase the effect of CO exposure. Individuals with cardiac or respiratory conditions are very susceptible to the dangers of carbon monoxide. CO poisoning is especially dangerous during sleep when victims are unaware of any side effects. The following are symptoms which may signal exposure to CO: • Tightness of chest or hyperventilation • Flushed face • Lack of normal coordination Persons who have been exposed to carbon monoxide should be moved into fresh air immedi- ately. Persons who have been subjected to high concentrations of CO should be placed in the care of a...
Open the catalog to page 5CMD-3M Carbon Monoxide Detector Should a very high level of carbon monoxide exist, the CMD-3M will alarm in a few minutes. However, if small quantities of CO are present or high levels are short-lived, the microcon- troller will accumulate the information and determine when an alarm level has been reached. This feature eliminates nuisance alarms. For example, in a boat it is possible to see high lev- els of CO for a very short time such as when docking or maneuvering. The CMD-3M take this all under consideration by totaling the quantity of CO detected over a period of time. The CMD-3M is...
Open the catalog to page 6Pleasure Boat and Yacht Installation Because of the high risk of carbon monoxide injuries due to the nature of boats, we recommend a carbon monoxide detector in "each sleeping area." Small craft with an open design may only require one CMD-3M for adequate protection. If any two sleeping areas are partitioned then one CMD-3M should be installed in each sleeping area. Larger craft often have aft and forward cabins with convertible sofas in the salon. These boats will require three CMD-3M monitors. Avoid installing a CMD-3M near a hatch or porthole through which sea water could be spilled on...
Open the catalog to page 7CMD-3M Carbon Monoxide Detector TO REMOVE CIRCUIT BOARD FROM BASE PLATE FOLLOW THESE TWO STEPS: 1. Push "locking pins" outward and lift bottom portion of board toward you. 2. Holding the board with one hand, pull to remove TO RE-INSTALL: Reverse this procedure. TO INSTALL CIRCUIT BOARD INTO BASE PLATE FOLLOW THESE TWO STEPS: FIGURE 2 1. Insert top of board (with 45' angles) under holding tabs on base plate. 2. Gently lower bottom until board "snaps" into locking pins. Follow applicable codes and regulations for wiring: Power Connection
Open the catalog to page 8CONTINUOUS OPERATION IS PREFERRED. If your power is unlimited, it is recommended that the CMD-3M be operated continuously day and night. This is the "healthiest" condition for solid state devices. In addition, it provides advance warning when entering an area where a hazard may exist. NOTE: For installations differing from those outlined above, please contact the engineering department of FIREBOY/XINTEX for application and suitability information. When power is initially applied to the CMD-3M, the (top) power indicator will flash on and off, followed by the red (lower) alarm indicator...
Open the catalog to page 9CMD-3M Carbon Monoxide Detector problems are identified during this inspection have the equipment serviced immediately. Note any combustion equipment not inspected by the technician and consult the manu- facturers' instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. NOTE: The CMD-3M will alarm at 10% COHb. SEE TABLE 2. The alarm will clear when the CO concentration has dropped below 70 parts per million. Nuisance Alarms Although the CMD-3M will detect only carbon monoxide in a normal environment, studies have found that unusually...
Open the catalog to page 10All Fireboy - Xintex catalogs and brochures
-
Deckhead Mounting Box
1 Pages
-
Sounder Beacon Base
1 Pages
-
Relay Output Module
1 Pages
-
Elite RSM Fire Alarm Control
2 Pages
-
Methane Detectors
4 Pages
-
Elite Networking
2 Pages
-
Sounder Control Module
1 Pages
-
Low Power Relay Base
1 Pages
-
Isolating Base
1 Pages
-
4? Mounting Base
1 Pages
-
Mini Monitor Module
1 Pages
-
Isolator
1 Pages
-
Discovery Heat Detector
2 Pages
-
12 Ah Battery
2 Pages
-
Multi Flex Sounder Base
2 Pages
-
Multi-Tone Strobe
3 Pages
-
Wall Mount Horn/Strobe
4 Pages
-
Fire Suppression & Detection
13 Pages
-
fire alarm
2 Pages
-
propaneSystems
4 Pages
-
MONITOR UP TO 16 ZONES
1 Pages
-
Elite RS-M
2 Pages
-
FIRE DETECTION SYSTEM
1 Pages
Archived catalogs
-
MethaneFumeDetector.pdf
1 Pages
-
GA Series
2 Pages