Catalog excerpts
Weatherproof Devices 24V Low Profile Evacuation Outdoor Horn/Strobe: VF4007-1M 24V Low Profile Evacuation Horn with Outdoor Enclosure: VF4028-10 USCG Type Approved 161.002/A53/0 Standard Features - UL 464, UL 1638 & BFP Listed - Nominal Voltage 24VDC - Unit is Shipped with UL1638 listed VF4007-1M Candela Horn/Strobe - Unit Dimensions: VF4008-10 5.75” High x 4.75” Wide x 4.18” Deep - To Obtain Outdoor Horn, Must Order VF4000--10 and VF400810 Separately - Super-SlideTM - Ease of Supervision Testing - CheckmateTM - Instant Voltage Verification - Lower Installation and Operating Costs - Switch Selection for High dBA - Switch for Mechanical and 2400Hz Tone - Switch for Continuous Tone - Tamperproof Re-entrant Grill - Wide Voltage Range 16-33 VDC or FWR - Separate Horn and Strobe Functions - Synchronize Strobe and/or Horn by Using Fireboy-Xintex Synchronization Control Module - Listed for UL1638 when used with the VF4008-10 enclosure - VF4008-10 Made of Clear Lexan Provides Maximum Visibility and Reliability for effective Visible Signaling - Allowing Full 75cd Output - Input Terminals 12 to 18 AWG - Faceplate available in Red The Outdoor Fireboy-Xintex Series offers dependable visible and/or audible alarms for all outdoor needs. - Included with the Fireboy-Xintex Series is the VF4008-10 outdoor enclosure. The enclosure is made of high quality Lexan material, providing protection from weather related conditions and allowing the necessary full candela output. This highly constructed enclosure meets various installation requirements including deterring moisture from entering the enclosures. - The Outdoor Series is equipped with the 4” mounting plate which incorporates the Super-Slide™ feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. - The Fireboy-Xintex Series also features the Checkmate™ - Instant Voltage Verification feature which allows the installer to check the voltage without removing the signal. - The Fireboy-Xintex Series strobe has a minimal operation current and has a minimum flash rate of 1Hz and can vary up to 2Hz regardless of input voltage. - The Fireboy-Xintex Series appliances are UL 464 and UL 1638 listed for use with fire protective systems and are warranted for one year from date of purchase. Fireboy-Xintex, Inc. O-379 Lake Michigan Drive Grand Rapids, MI 49534 . 616.735.9380 Fireboy-Xintex, Ltd Unit 10 Holton Road, Holton Industrial Estate Poole, Dorset BH166LT UK . 44 (0) 845 389 9462
Open the catalog to page 1Ordering Codes Part Number 24V Low Profile Evacuation Horn with outdoor enclosure, Red Faceplate Part Number 24V Evacuation Outdoor Horn/Strobe Wall Mount, Red Faceplate Ordering Codes Notes: The Fireboy-Xintex Outdoor Series is listed for outdoor use. Indoor Operating Temperature: 32° to 120°F. Outdoor Operating Temperature: -31° to 150°F. For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. Fireboy-Xintex does not recommend using a coded or pulsing signaling circuit with any of our...
Open the catalog to page 2Mounting Super-Slide Super-Slide™ Mounting Plate: Checkmate™ - Instant Voltage Verification Switch Locations The accessholes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measure- ments will be taken using the S+ and S- locations although accessis provided to other locations. NOTE: Care should be taken to not short the test probes. isolated horn and strobe power inputs. Conventional Fireboy-Xintex Series Wiring Diagrams Signal...
Open the catalog to page 3FU$£QI XlNfEX Wiring Diagram Fireboy-Xintex Series with Fireboy-Xintex Synchronization Module WIRING ONLY. AUDIBLE SIGNAL VISIBLE SIGNAL WIRING ONLY. WIRING ONLY. REMOVE JUMPER SYNCHRONIZED STROBE LEAVE JUMPERIN PLACE HORN INPUT ON AVSM TO NOTIFICATION ALARM CIRCUIT TO NOTIFICATION ALARM CIRCUIT LEAVE JUMPER IN PLACE ON SLAVE UNITS UNLESS SEPARATE CONTROL OVER HORN CKT WIRING ONLY Architects and Engineer Specifications The audible and/or visible signal shall be Fireboy-Xintex series or approved equal and shall be listed by Underwriters Laboratories, Inc. per UL 1971 and/or UL 464. The...
Open the catalog to page 4All Fireboy - Xintex catalogs and brochures
-
Deckhead Mounting Box
1 Pages
-
Sounder Beacon Base
1 Pages
-
Relay Output Module
1 Pages
-
Elite RSM Fire Alarm Control
2 Pages
-
Methane Detectors
4 Pages
-
Elite Networking
2 Pages
-
Sounder Control Module
1 Pages
-
Low Power Relay Base
1 Pages
-
Isolating Base
1 Pages
-
4? Mounting Base
1 Pages
-
Mini Monitor Module
1 Pages
-
Isolator
1 Pages
-
Discovery Heat Detector
2 Pages
-
12 Ah Battery
2 Pages
-
Multi Flex Sounder Base
2 Pages
-
Multi-Tone Strobe
3 Pages
-
Wall Mount Horn/Strobe
4 Pages
-
Fire Suppression & Detection
13 Pages
-
fire alarm
2 Pages
-
propaneSystems
4 Pages
-
MONITOR UP TO 16 ZONES
1 Pages
-
Elite RS-M
2 Pages
-
FIRE DETECTION SYSTEM
1 Pages
Archived catalogs
-
MethaneFumeDetector.pdf
1 Pages
-
Carbon monoxide detector
12 Pages
-
GA Series
2 Pages