Overview: The PL3701-I-W Electronic Level Transmitter is designed for measuring levels in service, ballast, slop, and water tanks, specifically in petroleum and chemical applications. It features a linearized ceramic sensor with a welded flange for side mounting, housed in IP68-rated 316L stainless steel.
Technical Specifications:
  • Pressure Ranges: 120 mbar to 4 bar
  • Overpressure Capacity: 6 to 25 bar
  • Accuracy: ±0.3% FS at 20°C
  • Protection Class: Transducer: IP68, Remote electronic box: IP66/67
  • Intrinsic Safety: IECEx, ATEX certified
  • Power Supply: 12-28 Vdc
  • Output Signal: 4-20 mA, 2-wires
  • Operating Temperature: Transducer: -40° to +125°C, Remote box: -25° to +85°C
  • Cable Length: Standard 3m, optional up to 50m
  • Materials: Stainless steel 316L for remote box, sensor, and flange; Ceramic diaphragm; Fire retardant polyethylene cable
Installation and Safety:
  • Recommended zener barrier: MTL7787+ for hazardous areas
  • Maximum sensor temperature: 125°C
  • Polyethylene cable temperature: up to 60°C (standard), PTFE cable up to 120°C (optional)
  • Mechanical connection via screwed ISO flange: PN40DN25 or PN16DN40
Contact Information: Honeywell Marine SAS, 9 rue Isaac Newton, ZA Port Sec Nord, Esprit 1, 18000 Bourges, France. Phone: +33 (0) 248 237 901, Email: [email protected]
Documentation: Includes installation manual (MI5090), technical manual (NT5090), and maintenance manual (MM5090).
See more

Catalog excerpts

PL3701-I-W Datasheet-1

The electrical level transmitter with welded flange - side mounting The PL3701-I-W Electronic Level Transmitter is a linearized, ceramic device specially designed for petroleum and chemical applications that measure level in service tanks, ballast tanks or slop and water tanks. It features an IP68-rated sensor through 316 L stainless steel housing and shielded polyester cable. The remote electronic box in stainless steel 316L includes the amplifier with zero and span adjustment.

 Open the catalog to page 1
PL3701-I-W Datasheet-2

Technical Data Dimensions & Fixation Mechanical Connection Protection class: - Transducer: IP68 - Remote electronic box: IP66/67 Intrinsic safety: IECEx, ATEX. II 1 G D Ex ia IIC T6 Ga or Ex ia IIB T6 Ga Ex ia IIIC T80°C Da IP66/67 (Max 50m cable between sensor and remote electronic box). Power supply: 12-28 Vdc Operating temperature ranges: - Transducer: - 40° to + 125°C - Remote electronic box: - 25° to + 85°C Cable length: 3m in standard (option: up to 50m) Material: - Remote box: Stainless steel 316L. - Sensor: Stainless steel 316L. - Diaphragm: Ceramic. - Flange: Stainless steel...

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.