LLLU Honeywell An atmospheric pressure transmitter The PL 3700 ATM provides reliable measurement of atmospheric pressure to the cargo gauging system, thus allowing precise and reliable measurement of level in the tanks equipped with pressure sensors of the PL3700 series. The PL3700 series is a ceramic family transmitter linearised on the whole range. The PL 3700 ATM transducer is specially designed to compensate with the atmospheric pressure, the use of absolute pressure transmitters in tank gauging system or inert gas pressure measurement. This capacitive transducer with high stability is approved by major classification
Open the catalog to page 1Technical Data Mechanical Fittings & Dimensions Absolute pressure range: 900 to llOOmbar Protection class: - Transducer: IP68 - Remote electronic box: IP66 Intrinsic safety: IECEx, ATEX Operating temperature ranges: - 25°C to + 85° Weight: 8OOgr Special Features Mechanical Connection Mechanical parts: - Remote Electronic box: Polyester - Sensor housing: 316L SS - Diaphragm: ceramic Ordering code: 30 969 For hazardous area installation, the transmitter must be installed with zener barrier Recommended zener barrier : MTL7787+ Technical Documentation Electrical Connection Installation...