SLC 2,3-12

SLC 2,3-12

SLC 2,3-12

Product catalog summary
Specifications
The AGM Sealed VRLA Battery has a nominal voltage of 12V and a nominal capacity of 2.3AH. Its dimensions are 179mm in length, 36mm in width, and 61mm in height, with a total height of 66mm. The battery weighs approximately 0.86kg and can handle a maximum discharge current of 34.5A for 5 seconds. The internal resistance is approximately 70 mΩ, and it uses a T1 standard terminal with an ABS container material.

Constant-Voltage Charge
For cycle applications, the initial current should be limited to less than 0.55A. Charging should continue until the battery voltage reaches 14.1V to 14.4V at 25ºC (77ºF). The voltage should be maintained until the current drops below 0.0132A for at least 3 hours. The temperature compensation coefficient for charging voltage is -30mV/ºC. For standby service, the battery should be held across a constant voltage source of 13.6 to 13.8 volts with a current limit of 0.55A continuously. The temperature compensation coefficient for standby service is -18mV/ºC.

Temperature and Storage
The nominal operating temperature range is 25±3°C (77±5°F). The discharge temperature range is -15 to 50°C, the charge temperature range is 0 to 40°C, and the storage temperature range is -15 to 40°C. The battery should be charged within 6 months of storage to prevent permanent capacity loss due to sulfation.

Performance Characteristics
The battery's capacity is affected by temperature, with 103% capacity at 40°C (104°F), 100% at 25°C (77°F), and 86% at 0°C (32°F). The document includes detailed tables for constant current and constant power discharge at various end voltages and time intervals, highlighting the battery's performance under different conditions.
See more

Catalog excerpts

SLC 2,3-12-1

SLC SERIES GENERAL PURPOSE BATTERIES AGM SEALED VRLA BATTERY 5-6 YEARS OF EXPECTED LIFETIME (EURO BAT) Nominal Operating Temp. Range 25±3°C (77±5°F) NOTE : The battery should be charged within 6 months of storage, Otherwise, permanent loss of capacity might occur as a result of sulfation

 Open the catalog to page 1
SLC 2,3-12-2

S L C 2,3-12DATASHEETCHARGE CHARACTERISTICS (25°C/77°F) DISCHARGE CHARACTERISTIC (25°C/77°F) CYCLE LIFE IN RELATION TO DEPTH OF DISCHARGE 120 TEMPERATURE VS FLOAT LIFE 100 ’ 80 ' 60 ENERPOWER S.R.L. UFFICI e DEPOSITO: Via Boccioni, 7 - 20900 MONZA (MB) Tel. + 39 (039)-832152 Fax +39 (039)-2230441 E-mail : [email protected] - https://www.enerpowersrl.com

 Open the catalog to page 2

All ENERPOWER S.R.L. catalogs and brochures

  1. SLC 33-12

    2  Pages

  2. SLC 26-12H

    2  Pages

  3. SLC 26-12

    2  Pages

  4. SLC 18-12

    2  Pages

  5. SLC 12-12

    2  Pages

  6. SLC 9-12H

    2  Pages

  7. SLC 9-12

    2  Pages

  8. SLC 7,2-12

    2  Pages

  9. SLC 7-12

    2  Pages

  10. SLC 5-12

    2  Pages

  11. SLC 3.6-12

    2  Pages

  12. SLC 1,2-12

    2  Pages

  13. SLC 4.5-6

    2  Pages

  14. GHL 200-12

    2  Pages

  15. GHL 140-12

    2  Pages

  16. GHL 120-12

    2  Pages

  17. GHL 100-12S

    2  Pages

  18. GHL 75-12

    2  Pages

  19. GHL 55-12

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.