Catalog excerpts
Demisting, heating and Ventilation unit Range VCD-BV The demisting, heating and ventilation units are designed for on-board applications. In winter, they ensure the heating of rooms (control cabins, wheelhouses or passenger accommodation) and allow the window demisting by a network of ducts and distributors. In summer, they can be used as a ventilation system for fresh air renewal in the rooms. In both cases, the fan flow is adjustable. These products are designed according to Bureau Veritas requirements. Range VCD-BV Power supply Characteristics * Cabinet supply voltage: Un 230/400/440Vac single phase or three phase 50/60Hz and 24, 48 or 72Vdc * Absorbed power: 1kW to 5kW (according to the characteristics) * * Blowing fan with air flow from 0 to 400m3/h and static pressure of 60mmCE * AC motor IP55 or DC motor * IP 23 protection * Cabinet dimensions H 660 x L 460 x D 240mm * Stainless steel tubular shielded electrical resistance * Operating temperature: -20 to 50°C * Humidity: from 0 to 95% without condensation
Open the catalog to page 1Presentation The demisting, heating and ventilation units are composed of: * Electric fan with adjustable speed * Heating batteries with shielded stainless resistors, pin type * A safety thermostat * Distributors to be placed at the bottom of the windows * Deported remote control box * System to avoid overheating Duct junction The output duct junction is by a diameter 130mm Air distributor There are different distributor sizes (please refer to the chart below), they are fitted with baffle at 15° and orientate the air towards the window. As a standard, colourless anodised protection and...
Open the catalog to page 2All ENAG catalogs and brochures
-
ALT range – 72Vdc-300A
2 Pages
-
ALT-ADT range – 28Vdc mobile
2 Pages
-
BDB range – Mobile discharge
2 Pages
-
DC/DC CONVERTER – SD RANGE
2 Pages
-
RADIATOR – RAEL RANGE
2 Pages
-
ADM-SB – C13100 range
4 Pages
-
Water separator
4 Pages
-
ONS range – AC/DC – Sinus
2 Pages
-
Propeller pitch indicator
2 Pages
-
Marine Battery
2 Pages
-
SD range – 12/48/110V
2 Pages
-
Battery monitor for JBNUM-II
2 Pages
-
CDS4 H range
2 Pages
-
CDS4 range – 12/24V
4 Pages
-
CDS3 range – 24V – BV
2 Pages
-
CDS3 range – 12/24/48V
2 Pages
-
CDS range – 12/24V
2 Pages
-
24Vdc alternator
2 Pages
-
Shaft line alternator
1 Pages
-
ADM-SB range – Marine
2 Pages
-
ADM-SB range – AC/DC
4 Pages
-
SQ range
2 Pages
-
ALM-ALT range – AC/DC
2 Pages
-
Grille pare-pluie marine
1 Pages
-
DC/DC converters - SD Range
2 Pages