DC manual - 1

MODULAR SERIES OWNERS MANUAL 4-5 Standard System Features, Options and Accessories 10 Installation Instructions Options 11-13 System Operation, Shut Down and Flush Procedure 15 Pressure Vessel End Plug Changing Procedure 17-19 High Pressure Pump Diagram and Parts List

Open the catalog to page 1
DC manual - 2

Thank you for choosing an ECH2O Tec. reverse osmosis watermaker. We trust that you will be completely satisfied with our product. We inspect and test all system components before shipping and feel we have manufactured one of the finest products on the market. The purpose of this manual is to allow you to become familiar with each component of your new By understanding the function, importance and normal operation of each part in the system, the operator can readily diagnose problems when they first develop. Such problems are easily corrected and require minor adjustments. If left...

Open the catalog to page 2
DC manual - 3

Rated Performance: Reverse Osmosis performance varies with the feed water temperature. The rated performance is tested at 26°C / 80°F water temperature at a salinity of 33g/ltr. Standard size high rejection TFC Polyamide, thin film composite, spiral wound, single pass reverse osmosis element. Product Water TDS Range: less than 500ppm TDS Salinity Range: up to 50,000ppm TDS (NaCl) Chlorine Tolerance: lOOOppm hours Feed Water Pressure: 5"Hg to 60psi Feed Water Temperature Range: Electrical Power Requirements: 12.5VDC 25VDC

Open the catalog to page 3
DC manual - 4

STANDARD SYSTEM FEATURES 1 Filter housing with 1 hose barb outlet (1/2" with boost pump or 5/8" without boost 1 Bracket with 8 screws 1 Intake 3-way valve with 2 hose barb fittings (Service: 5/8", Intake: 1/2" with or 5/8" 1 Titanium reinforced stainless steel high pressure pump with electric motor. 1 40" Pressure vessel with reverse osmosis membrane (model 200 / 240 / 260) 1 316 Stainless steel control panel 1 Automatic pressure regulator valve 1 High pressure gauge 1 Product flow meter 1 Diverter (3 way) valve with 3/8" compression fittings 12 feet / 3.5m high pressure hose with 2 316...

Open the catalog to page 4
DC manual - 5

AVAILABLE OPTIONS AND ACCESSORIES If the high pressure pump is installed less than 1 foot under the waterline or an additional 5 micron pre-filter is added, the installation of an optional boost pump is Boost pump (intake hose barb, outlet hose barb, 4 feet / 1.2 meter 5/8" wire reinforced intake hose, 10 feet / 3 meter 1/2" braided feed hose) Fresh water flush kit with boost pump (filter housing, charcoal cartridge, 316 bracket, 8 screws, shut off valve 1/2", 2 x 1/2" hose barb connectors, 1/2" tee, 10ft 1/2" braided hose, 6 x 1/2" hose clamps) Fresh water flush kit without boost pump...

Open the catalog to page 5
DC manual - 6

Watermakers ECH2O Tec. BOOST PUMP PUMP MODULAR-SERIES SYSTEM SEA WATER INLET STRAINER FRESH WATER INTAKE EXSISTING FRESH WATER TANK SAMPLE OUTLET 5µ FILTER 31/05/06 DATE 3.1 REV. MS DRWN PRE-FILTRATION SYSTEM 20µ FILTER PSI LOW PRESSURE GAUGE FILTER FRESH WATER FLUSH FILTER FRESH WATER OUTLET PRESSURE CONTROL VALVE REJECT WATER REJECT WATER OUTLET HIGH PRESSURE PUMP UNIT MEMBRANE MEMBRANE R.O. MEMBRANE VESSEL RACK CLEANING / STORAGE SOLUTION INTAKE FLOW PSI HIGH PRESSURE GAUGE CONTROL PANEL FLOW DIAGRAM WITH OPTIONS

Open the catalog to page 6
DC manual - 7

INSTALLATION INSTRUCTIONS HIGH PRESSURE PUMP WITH ELECTRIC MOTOR Mount the high pressure pump/motor unit horizontally in a dry and ventilated location. CAUTION: OPEN GEARS MAY CAUSE PERSONAL INJURY. MOUNT THE BELT DRIVE OF THE SYSTEMS 200 / 240 / 260 IN A POSITION WHERE IT CANNOT BE ACCIDENTLY REACHED OR COVER THE GEARS. The electrical installation should only be done by a professional electrician. Electrical installation MEMBRANE HOUSING Mount the high-pressure membrane housing(s) with the provided brackets vertical (with the flow upwards) or horizontal in a convenient location away from...

Open the catalog to page 7
DC manual - 8

PRE-FILTER HOUSING Mount the pre-filter in a serviceable location and connect the bottom port of the cleaning / storage valve with 5/8" reinforced vinyl hose to the bottom intake hose fitting of the high-pressure pump. Secure the hose with hose clamps. INSTALL ALL PLUMBING TO ELIMINATE ANY AIR POCKETS IN THE SYSTEM CAUTION: USE A MAXIMUM OF THREE WRAPS OF TEFLON TAPE ON ALL THREADS TO PREVENT LEAKAGE, IF YOU HAVE TO RE-SEAL FITTINGS. ALWAYS KEEP THE TAPE BACK FROM THE END OF THE FITTINGS (AT LEAST TWO THREADS). DO NOT ALLOW ANY TAPE TO ENTER THE SYSTEM. HIGH PRESSURE HOSE The high pressure...

Open the catalog to page 8
DC manual - 9

PRODUCT WATER TUBING Connect 3/8" product water tubing or 3/8" vinyl hose from the center fittings of the membrane housing(s) to the bottom inlet of the flow meter, in the control panel. Connect the tubing or hose from each output port of the 3-way valve to your water tank and to the taste/test station of your choice. CAUTION: UNDER NO CIRCUMSTANCES SHOULD THE PRODUCT WATER LINE BE ALLOWED TO BECOME BLOCKED WHILE THE SYSTEM IS RUNNING. DO NOT INSTALL SHUT-OFF VALVES ANYWHERE IN THIS LINE. CAUTION: DO NOT ALLOW CHLORINATED WATER FROM YOUR STORAGE TANK TO FLOW BACK INTO THE R.O. MEMBRANE. You...

Open the catalog to page 9
DC manual - 10

INSTALLATION INSTRUCTION (OPTIONS) Boost Pump If the high-pressure pump is installed less than 1 foot under the waterline or an additional 5micron pre- filter is added, the installation of an optional boost pump is recommended. Install the boost pump below the water line, in between a sea strainer and the pre-filter(s). The intake is The ECHO Tec. "Orbital" Magnetic Drive Pumps eliminate the conventional shaft seals found in most pumps. This means that there is no rotating seal to wear and allow the liquid being pumped to leak out. We rely on the liquid being pumped to lubricate the magnet...

Open the catalog to page 10
DC manual - 11

SYSTEM OPERATION INSTRUCTIONS The reverse osmosis membrane contains a preservative solution to prevent microbiological growth. If ingested, may cause irritation of the gastro-intestinal tract, Colic, diarrhea, or other similar symptoms. Therefore, discard all the product water for at least thirty minutes of initial operation, after storage before drinking or before use in food preparations! Do not operate the system using contaminated feed water sources (oil, chlorine or other Have you filled the high-pressure pump with the proper amount of oil (SAE90 gearbox oil) center of show glass or...