Overview: This document provides comprehensive information on Eaton's solar inverters and electrical balance of system components, focusing on direct current (DC) circuit breakers, PVGard solar circuit breakers, DC switch disconnectors, DC switches, DC switched combiners, and dry-type distribution transformers.
1. Direct Current Circuit Breakers:
  • Product Description: Eaton offers a variety of molded case circuit breakers and switches for DC systems, suitable for applications such as UPS battery supply circuits, solar systems, and electric vehicle charging. These breakers are UL 489 listed and applicable in both ungrounded and select grounded applications.
  • Specifications: Current ratings range from 15 to 2500A, with various voltage and interrupting ratings. Optional accessories include remote tripping and breaker status indication.
  • Catalog Number Selection: A detailed guide is provided for selecting catalog numbers based on frame type, number of poles, trip unit ampere rating, and suffix options.
  • Product Selection: Lists various types of DC circuit breakers with their maximum continuous ampere ratings and catalog numbers for both complete breakers and frames only.
2. PVGard Solar Circuit Breakers:
  • Product Overview: Designed for solar photovoltaic applications, these breakers support 600 Vdc per-pole and 1000 Vdc poles-in-series configurations.
  • Features and Standards: Includes features like high interrupting capacity and compliance with relevant standards and certifications.
3. DC Switch Disconnectors and Switches:
  • Product Description: Details on DC switch disconnectors and switches, including their applications and features.
4. Dry-Type Distribution Transformers:
  • Product Description: Information on encapsulated and ventilated transformers, suitable for various distribution applications.
Technical Data and Specifications: The document includes technical data, specifications, wiring diagrams, and dimensions for each product category, ensuring comprehensive understanding and application.
Product Overview: The document provides an overview of Eaton's PVGard solar circuit breakers, which are designed for photovoltaic (PV) systems. There are two main product lineups: 600 Vdc per-pole breakers and switches, and 1000 Vdc poles-in-series breakers and switches. Both options are UL 489B listed for solar photovoltaic circuit protection and are calibrated at 50°C. The breakers are available in both 100% and 80% rated versions and can handle bi-directional current flow.
Product Description: PV systems convert solar energy into electrical power for the grid. PVGard circuit breakers protect the wiring from PV modules to the combiner or inverter, acting as a disconnect. Eaton's PVGard breakers combine disconnect and circuit protection in a compact, resettable device, replacing fuses and disconnects in combiner box and inverter applications. This saves space, streamlines design, and reduces spare parts requirements.
PVGard 600 Vdc Per-Pole Lineup: This lineup offers significant space, time, and cost savings by eliminating the need for jumpers for poles-in-series connections. It is designed for residential and light commercial applications.
PVGard 1000 Vdc Poles-in-Series Lineup: Suitable for commercial and utility-scale PV systems, this lineup provides reliable disconnect means and overcurrent protection without requiring jumpers, offering design flexibility.
Features: PVGard breakers are designed to meet the higher voltage and lower fault current levels of solar systems. They are tested for extreme ambient conditions and can handle bi-directional current flow. They are applicable in grounded, ungrounded, or bi-polar systems and meet UL 489B standards. The breakers are available in both standard and 100% rated versions, with a wide range of current ratings.
Standards and Certifications: The breakers are designed to meet UL 489B standards for solar photovoltaic circuit protection and are listed under UL File E350638.
Product Selection: The document provides detailed catalog numbers for various breaker frames and trip units, specifying current ratings and configurations for both 600 Vdc and 1000 Vdc options.
Accessories: A range of accessories is available, including auxiliary switches, shunt trips, electrical operators, and lock-off devices. Optional modifications such as freeze testing are also offered.
Conclusion: Eaton's PVGard solar circuit breakers offer a comprehensive solution for PV system protection, combining space-saving design with robust performance and flexibility for various applications.
Overview: The document provides information on Eaton's range of dry-type distribution transformers, specifically focusing on ventilated transformers and open core-coil assemblies. These transformers are available in NEMA 3R stainless steel or NEMA 4X enclosures, with the core and coil assembly embedded in a sand and resin compound to protect against moisture and contaminants.
Product Specifications: Eaton offers both ventilated and totally enclosed non-ventilated transformers. These products come in various K-factor ratings and efficiency levels, catering to different commercial distribution needs. The document references Volume 2—Commercial Distribution, CA08100003E, Tab 2 for more detailed information on standard product offerings.
Custom Design Capabilities: In addition to standard products, Eaton provides custom design services to meet specific requirements of the solar industry. This includes special dimensions, layouts, and designs to achieve CEC weighted-efficiency levels or other necessary efficiency standards. Customers are encouraged to contact their local Eaton representative for more information on custom design options.
Additional Resources: For further details, the document suggests referring to Volume 15—Solar Inverters and Electrical Balance of System CA08100018E—May 2016 available at eaton.com/solar.
See more

Catalog excerpts

Solar OEM-1

Solar OEM Direct Current Circuit Breakers Direct Current Circuit Breakers Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 PVGard Solar Photovoltaic Circuit Breakers Dry-Type Distribution Transformers Encapsulated Transformers Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ventilated Transformers/Open Core-Coil Assemblies Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Switched Combiners Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Switches Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DC Switch Disconnectors Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dry-Type Transformer Family PVGard Solar Circuit Breakers— 600 Vdc Per-Pole and 1000 Vdc Poles-in-Series Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Volume 15—Solar Inverters and Electrical Balance of System CA08100018E—May 2016 eaton.com/solar

 Open the catalog to page 1
Solar OEM-2

Direct Current Circuit Breakers Specialty Breakers Direct Current Circuit Breakers Direct Current Circuit Breakers Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Direct Current Circuit Breakers Product Description DC (direct current) systems and applications are becoming commonplace as alternative energy sources have expanded and the...

 Open the catalog to page 2
Solar OEM-3

Specialty BreakersQuick Reference Direct Current Circuit Breakers UL 489 Interrupting Capacity Ratings Interrupting Capacity (kA) Volts DC 1 Circuit Breaker Type Maximum Amperes Circuit Breaker Maximum 125 Volts DC Poles in 250 Volts DC Poles in 600 Volts DC Poles in Type Amperes Icu Ics Series Icu Ics Series Icu Ics Series Notes 1 DC ratings apply to substantially non-inductive circuits. Time constants per UL 489. 2 EGEDC through HMDLDC have been tested up to 300 Vdc to allow for battery charging voltages. 750 Vdc is common in transportation applications. HFDDC,...

 Open the catalog to page 3
Solar OEM-4

Direct Current Circuit Breakers Specialty Breakers Catalog Number Selection DC Circuit Breaker HFDDC 3 150 W Frame EGEDC = Series G—E (100A max.) EGSDC = Series G—E (100A max.) EGHDC = Series G—E (100A max.) HFDDC = Series C—F (225A max.) JGEDC = Series G—J (250A max.) JGSDC = Series G—J (250A max.) JGHDC = Series G—J (250A max.) HJDDC = Series C—J (250A max.) HKDDC = Series C—K (400A max.) LGEDC = Series G—L (600A max.) LGSDC = Series G—L (600A max.) LGHDC = Series G—L (600A max.) HLDDC = Series C—L (1200A max.) HMDLDC = Series C—M (800A max.) NBDC = NB (1200A max.) Number of Poles 1 = Single-pole 2...

 Open the catalog to page 4
Solar OEM-5

Specialty Breakers Maximum Continuous Ampere Rating at 40°C Complete Circuit Breaker Complete Circuit Breaker with Terminals without Terminals Catalog Catalog Number Number Complete Circuit Breaker Complete Circuit Breaker with Terminals without Terminals Catalog Catalog Number Number Complete Circuit Breaker Complete Circuit Breaker with Terminals without Terminals Catalog Catalog Number Number Volume 15—Solar Inverters and Electrical Balance of System CA08100018E—May 2016 eaton.com/solar

 Open the catalog to page 5
Solar OEM-6

Direct Current Circuit BreakersSpecialty Breakers Type HFDDC DC Circuit Breakers— Three-Pole High Interrupting Capacity 42 kAIC at 600 Vdc Maximum Continuous Ampere Rating at40°C Complete Circuit Breaker with Line and Load Terminals 1 Single-Pole Catalog Number Two-Pole Catalog Number Three-Pole Catalog Number Four-Pole Catalog Number Type JGEDC DC Circuit Breakers— Three-Pole High Interrupting Capacity 35 kAIC at 600 Vdc Maximum Continuous Ampere Rating at 40°C Complete Breaker Catalog Number Circuit Breaker Frame Only ® Catalog Number Notes 1 For breaker without terminals, replace "L" with...

 Open the catalog to page 6

Archived catalogs

  1. Lighthouse®

    2  Pages

  2. LED Lighting

    1  Page

  3. DeckHand

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.