SVS14
6Pages

{{requestButtons}}

Catalog excerpts

SVS14 - 1

Power distribution system SVS14 Description The power distribution system SVS14-10 optimises DC 24 V distribution on the field level in automated process control, industrial production and chemical plants. The system holds an integral ammeter (display 25 A) for the total current and offers ten ways for electronic and thermal-magnetic circuit breakers including group signalling. It allows protection of transformers, actuators, solenoids, peripheral PLCs, intelligent terminals etc. on the field level. Particularly for systems with a great number of sensors/actuators the SVS14 power distribution system enables a space-saving and cost-effective design of protection control cabinets. Any load circuit which might be disconnected due to overload or short circuit generates a single signal which will be summarised in a group signal directly on the power distribution system and which will be fed back directly to control. The SVS14 is a track-mountable system and accommodates 10 electronic or thermal-magnetic circuit breakers. All terminals (entry line DC +24 V, GND (-) for self-supply, load outputs L(+) and group signalling are standard screw terminals. Technical data (Tamb = 25 °C, UB = DC 24 V) Application The SVS14 accommodates the following E-T-A types: Electronic circuit breaker ESS20-003.. Electronic circuit protector ESX10-103.. Thermal-magnetic circuit breaker 2210-S211, 3600-P10, 3900-P10 Systematic integration of power distribution, protection and signalling functions Power distribution and selective protection of DC 24 V loads from a single source Group signalling pre-wired Integral Si contact (per way) for free slots, Si circuit can be closed. Ordering information Type SVS14 Power distribution system for ESS20-003, ESX10-103 l Short circuit limited DC 24 V applications l Max. 25 A cont. load l Integral group signalling terminals S2 S1, DC 24 V / max. 0.5 A to be protected separately l Integral Si contact (per way) for free slots, Si circuit can be closed l Including 2 end pieces X 222 004 01 Version, max. number of circuit breakers 10 10 circuit breakers (F1...F10) Population option, load output C22 Fully populated with pcb screw terminals (double level) (max. 4 mm2, without wire end ferrule) Integral ammeter A01 Ammeter 90° to rail (vertical mounting position) (25 A / class 1.5 % / 48x48) A02 Ammeter 0° to rail (horizontal mounting position) (25 A / class 1.5 % / 48x48) Special version Sxxx SVS14 - 10 - C22 - A01 Ordering example Modular power distribution system for current limited DC 24 V - applications. In the event of current supply rated higher than 25 A and with battery-buffered supplies please use a 25 A protection with medium delay trip curve (e.g. E-T-A type 4220-T, 2210-T). Supply Rated voltage: DC 24 V (18...32 V) Total current: max. 25 A DC 24 V (+) terminal block X21 2+/1+ DC 24 V (-) terminal block X21 2-/1- Terminals: 4-pole screw terminals cable cross section max. 16 mm2 (with and without wire end ferrule) Gauge: Ammeter DIN 48, current rating 25 A (moving-iron instrument, 1.5 %) F ways Ten ways for circuit breaker, prepared for types ESS20-003, ESX10-103, 2210-S211, 3600-P10, 3900-P10 SVS14-10 / 10-way / F1… F10 = terminal X1+/X1-…X10+/X10Load outputs per way (F1...F10) Rated voltage: DC 24 V (18...32 V) Current: max. 8 A per way1) Number: 1 protected load output L(+) (at way F1 on terminal X1+) 1 minus return load (at way F1 on terminal X1-) Terminals: 2-pole double level terminal with screw terminal cable cross section max. 4 mm2 (with and without wire end ferrule) Signalling Signal terminal X31 (S2, S1) for group signal Rated voltage: DC 24 V (18...28 V) Total current: max. 0.5 A (Caution: use external protection 0.5 A/fast) S1 External supply possible + DC 24 V for signalling S2 Signal output, group signal of ways F1…F10 Terminals: 2-pole double level terminal with screw terminal cable cross section max. 4 mm2 (with and without wire end ferrule) 1) When mounted side-by-side and full population with circuit breakers type ESS20, ESX10, 2210, 3600 and 3900 with current rating 10 A, each device should carry only 80 % of its rating. Accessories: external jumper and end piece see page “Accessories“

Open the catalog to page 1
SVS14 - 2

Power distribution system SVS14 Technical data (Tamb = 25 °C, UB = DC 24 V) Termination C22 Supply terminal X21: screw terminals max. 16 mm2 - with and without wire end ferrule 0.5 - 16 mm2 - stripped length 10 mm - screw terminals M4 - tightening torque 1.2 - 1.5 Nm Load outputs terminal X1… X10: double level screw terminals - with and without wire end ferrule - stripped length - screw terminals - tightening torque Signalling terminal X31: screw terminals max. 2.5 mm2 - with and without wire end ferrule 0.25 – 2.5 mm2 - stripped length 7 mm - screw terminals M3 - tightening torque 0.5 -...

Open the catalog to page 2
SVS14 - 3

Power distribution system SVS14 Dimensions SVS14-10-C22-A01 (vertical mounting position) If the power distribution system is not completely fitted with circuit breakers the open signal way can be closed with a switch. DIN rail EN 50022-35x7.5 (not part of the product) Terminals current supply (++/--) screw terminals 16 mm2 max. 25 A Load outputs screw terminals double level 4 mm2 max. 8 A Depending on version marking (X) Group signalling screw terminals 2.5 mm2 max. 0.5 A Mounting position SVS14-10-C22-A01 (vertical mounting position)

Open the catalog to page 3
SVS14 - 4

Power distribution system SVS14 Application example SVS14-10-C22-A01 fitted with ESX10-103 Please order the required population option separately.

Open the catalog to page 4
SVS14 - 5

Power distribution system SVS14 Dimensions SVS14-10-C22-A02 (horizontal mounting position) DIN rail EN 50022-35x7.5 (not supplied with the product) 184 7.24 If the power distribution system is not completely fitted with circuit breakers, the signal way can be closed with a switch. Depending on version marking (X) Group signalling screw terminals 2.5 mm2 max. 0.5 A Load outputs screw terminals double level 4 mm2 max. 8 A Terminals current supply (--/++) screw terminals 16 mm2 max. 25 A Mounting position SVS14-10-C22-A02 (horizontal mounting position)

Open the catalog to page 5

All E-T-A Elektrotechnische Apparate catalogs and brochures

  1. MPR10

    4 Pages

  2. SVS15

    8 Pages

  3. SVS16

    6 Pages

  4. SVS18

    6 Pages

  5. SVS20

    8 Pages

  6. PP-M-PM024

    6 Pages

  7. PP-M-DC024

    6 Pages

  8. E-1048-8D...

    4 Pages

  9. 3131-A

    6 Pages

  10. ESR10

    4 Pages

  11. 1620

    2 Pages

  12. D_8340-G2

    5 Pages

  13. D_1120

    3 Pages

  14. D_1110

    2 Pages

  15. E-1048-8D

    3 Pages

  16. E-1048-8I

    5 Pages

  17. E-1048-8C.

    4 Pages

  18. 8340-F

    6 Pages

  19. 8340-G2

    5 Pages

  20. 1610-21

    3 Pages

  21. 1110

    2 Pages

Archived catalogs