Catalog excerpts
PowerPlex® Power Module PP-M-DC024 Description The PowerPlex® Power Module has primarily been designed for DC 12 V and DC 24 V on-board electrical systems of leisure boats and work boats. It provides inputs for switches and sensors as well as power outputs. The patented Four Level Protection Concept (FLPC) offers redundant overload protection. In addition the E-T-A circuit breakers integrated in the Power Modules allow manual activation of the 8 A and 25 A outputs. PowerPlex® is a decentralised power distribution and control system. All PowerPlex® modules ensure reliable control and monitoring of the electrical installations on board, either alone or in combination with other PowerPlex® components. Besides the protection against overcurrent they allow readout of data of the connected level sensors and temperature sensors as well as of shunts. All modules of a system communicate and interact via an SAEJ1939-compliant CAN bus. PowerPlex® is configured by using the PowerPlex® Configuration Software and the configuration is transferred to the modules by means of USB/CAN converters. US patent number: US 7,633,022 B2 well-proven CAN technology redundant protection - Four Level Protection Concept (FLPC) programmable overload protection simple configuration Windows based configuration software integral diagnostic and monitoring functions wire break detection inputs for analogue sensors eight channel dimming function (8 A + 25 A outputs) Approvals Authority Voltage ratings Current ratings Rules VI, part 7, GL 2012, category C, H, EMC1 Lloyd’s Register DC 12 V / DC 24 V 9…32 V DC 102 A IP22 in a vertical mounting position with the main power connectors downwards Operating temperature range Voltage rating UN Operating voltage UB Max. total current per module Degree of Protection watercraft, e. g. recreational and work boats special vehicles Technical data -40…+85 °C (-40…+185 °F) Storage temperature range -40…+85 °C (-40…+185 °F) Humid heat (IEC 60068-2-30, Db) 55 °C / 95 % RH, 24 hours Vibration sinusoidal (IEC 60068-2-6, Fc) 2 Hz to 13.2 Hz: ± 1 mm 13.2 Hz to 100 Hz: acceleration 0.7 g Shock (IEC 60068-2-27, Ea) 30 g (11 ms) EMC (EMC directive, CE logo) emission: EN 61000-6-3 susceptibility: EN 61000-6-2 Mass approx. 1.630 g Interfaces: CAN according to SAE J1939 250kBit/s The CAN-terminals at each end of the bus require a termination by a 120 Ω resistor. Inputs 8 inputs for switches or momentary switches digital inputs: 0...50 Ω: ON; > 100 kΩ: OFF 4 analogue inputs 0…10 V analogue input: Rin: 40 kΩ; resolution: 10 bit Outputs 6 outputs with 8 A max. continuous current load output: Power MOSFET, high side switching max. current rating: 8A adjustable from 1 A to 8 A in 1 A steps dimmable in 10 steps with 100 Hz PWM typical voltage drop UON at rated current (at 25 °C): 60 mV overload tripping range: 1.01...1.30 x IN trip time: adjustable from 100 msec to 6 s current limitation: typically 60 A at DC 24 V leakage current in OFF condition: 4 µA wire breakage monitoring in ON and OFF condition of load: wire breakage tresholds: OFF condition: RLoad: typically > 5 kΩ ON condition: ILoad typically < 200 mA additional overload protection by means of one E-T-A circuit breaker type 1610-21-10 A per output Comliant with IEC 60533 Electrical and electronic installations in Ships – Electromagnetic compatibility
Open the catalog to page 1PowerPlex® Power Module PP-M-DC024 Technical data marking of terminals strain relief voltage supply (+) pole Top S1 SR S2 SR S3 8 inputs, with a return each (S1-S8) Right side flashing frequency refer to manual flashing frequency refer to manual 4 load outputs 1 A, with a return each Signal output Configurable Signal Outputs: 8 status indicators (LEDs) can be configured to show the status of the load outputs 6 load outputs 8 A, with a return each fault, short circuit/ overcurrent flashing quickly fault, wire break flashing slowly Note: Refer to installation manual for installation and...
Open the catalog to page 2PowerPlex® Power Module PP-M-DC024 Dimensions – Version 1 Mounting mounting bracket 2 (not included in delivery, see accessories) mounting bracket 1 (included in delivery) Installation drawings minus terminal (-) field for module address Installation drawings 1 The module is designed for wall mounting by means of the fittings provided The module is designed for wall mounting by means of the fittings provided field for module adress strain relief snap-on cover This is a metric design and millimeter dimensions take precedence. Applicable for normal dimensions without direct tolerance...
Open the catalog to page 3PowerPlex® Power Module PP-M-DC024 Overview (without snap-on cover) space for module address label screw M3x8 max. tightening torque 80 Ncm L-profile Included in delivery: screw M3x8 L-profile centre mounting screw strain relief Caution: Mounting positions and sequence must be observed Typical time/current characteristics Programmable delay times available for overload tripping 25 ms*, 50 ms*, 100 ms, 200 ms, 500 ms, 750 ms*, 1 s*, 2 s*, 4 s*, 6 s* * not rececommended Ubat = 24 V, TA = 23 °C Curve 8 A, delay 100 ms
Open the catalog to page 4PowerPlex® Power Module PP-M-DC024 Circuit Labels Y 308 539 02 trim tabs fuel gauge illumination salon courtesy lights water tank sewage tank windshield wiper windshield wiper startboard windshield wiper centre windshield wiper portside clear view screen clear view screen startboard bilge alarm fire alarm pyrogenic system clear view screen centre clear view screen portside signal horn navigation instruments wind force meter deep freezer fish finder desalination system blue light weather decoder anchor light signal lights emergency flash mobile radio disabled signal position lights starbord...
Open the catalog to page 5PowerPlex® Power Module PP-M-DC024 Accessories USB/CAN converter: PowerPlex® Configuration Software Circuit breakers for replacement 1610-21: 1610-21-10 A 1610-21-30 A cable length including USB connector approx. 740 mm Connection to CAN bus via D-SUB plug, 9-pin 1 Pin assignment D-SUB output plug PIN 2 7 assignment CAN-L CAN-H This is a metric design and millimeter dimensions take precedence. Applicable for nominal dimensions without direct tolerance indication: DIN ISO 286 ± IT 13. Refer to product datasheet for installation and safety instructions. All dimensions without tolerances are...
Open the catalog to page 6All E-T-A Elektrotechnische Apparate catalogs and brochures
-
High Power-D-Box®
4 Pages
-
Economy Power-D-Box®
4 Pages
-
PBM-1170-05-V0060
2 Pages
-
PBM-E1048-8..-B.-V0089
3 Pages
-
PowerPlex® Power Module
6 Pages
-
PowerPlex® Panel Module
6 Pages
-
PowerPlex® Compact Module
6 Pages
-
MPR10
4 Pages
-
SVS14
6 Pages
-
SVS15
8 Pages
-
SVS16
6 Pages
-
SVS18
6 Pages
-
SVS20
8 Pages
-
PP-M-PM024
6 Pages
-
E-1048-8D...
4 Pages
-
3131-A
6 Pages
-
ESR10
4 Pages
-
1620
2 Pages
-
PowerPlex® Touch Panel 4.3?
2 Pages
-
D_8340-G2
5 Pages
-
D_1120
3 Pages
-
D_1110
2 Pages
-
E-1048-8D
3 Pages
-
E-1048-8I
5 Pages
-
E-1048-8C.
4 Pages
-
8340-F
6 Pages
-
8340-G2
5 Pages
-
1610-21
3 Pages
-
1110