PowerPlex® Power Module
6Pages

{{requestButtons}}

Catalog excerpts

PowerPlex® Power Module - 1

Description The PowerPlex® Power Module has primarily been designed for DC 12 V and DC 24 V on-board electrical systems of leisure boats and work boats. It provides inputs for switches and sensors as well as power outputs. The patented Four Level Protection Concept (FLPC) offers redundant overload protection. In addition the E-T-A circuit breakers integrated in the Power Modules allow manual activation of the 8 A and 25 A outputs. PowerPlex® is a decentralised power distribution and control system. All PowerPlex® modules ensure reliable control and monitoring of the electrical installations on board, either alone or in combination with other PowerPlex® components. Besides the protection against overcurrent they allow readout of data of the connected level sensors and temperature sensors as well as of shunts. All modules of a system communicate and interact via an SAE-J1939-compliant CAN bus. PowerPlex® is configured by using the PowerPlex® Configuration Software and the configuration is transferred to the modules by means of USB/CAN converters. US patent number: US 7,633,022 B2 • watercraft, e. g. recreational and work boats • special vehicles • well-proven CAN technology • redundant protection - Four Level Protection Concept (FLPC) • programmable overload protection • simple configuration • Windows based configuration software • integral diagnostic and monitoring functions • wire break detection • inputs for analogue sensors • eight channel dimming function (8 A + 25 A outputs) Voltage rating UN DC 12 V / DC 24 V Max. total current per module 102 A Degree of Protection IP22 in a vertical mounting position with the main power connectors downwards Operating temperature range -40...+85 °C (-40...+185 °F) Storage temperature range -40...+85 °C (-40...+185 °F) Humid heat (IEC 60068-2-30, Db) 55 °C / 95 % RH, 24 hours 13.2 Hz to 100 Hz: acceleration 0.7 g Shock (IEC 60068-2-27, Ea) 30 g (11 ms) EMC CE marking to Interfaces: CAN according to SAE J1939 250kBit/s The CAN-terminals at each end of the bus require a termination by a 120 Q resistor. Approvals Authority Inputs 8 inputs for switches or momentary switches digital inputs: 0...50 Q: ON; > 100 kQ: OFF analogue input: Rin: 40 kQ; resolution: 10 bit Outputs 6 outputs with 8 A max. continuous current load output: Power MOSFET, high side switching adjustable from 1 A to 8 A in 1 A steps dimmable in 10 steps with 100 Hz PWM typical voltage drop UON at rated current (at 25 °C): 60 mV overload tripping range: 1.01...1.30 x IN trip time: adjustable from 100 msec to 6 s current limitation: typically 60 A at DC 24 V wire breakage monitoring in ON and OFF condition of load: wire breakage tresholds: OFF condition: RLoad: typically > 5 kQ ON condition: ILoad typically < 200 mA additional overload protection by means of one E-T-A circuit breaker type 1610-21-10 A per output Comliant with IEC 60533 Electrical and electronic installations in Ships - Electromagnetic compatibility

Open the catalog to page 1
PowerPlex® Power Module - 2

Technical data 2 outputs with 25 A max. continuous current load output Power MOSFET, high side switching adjustable from 10 A to 25 A in 2 A steps dimmable in 10 steps with 100 Hz pWm typical voltage drop UON at rated current (at 25 °C): 60 mV overload tripping range: 1.01...1.30 x IN trip time: adjustable from 100 msec to 6 s current limitation: typically 270 A at DC 24 V wire breakage monitoring in ON and OFF condition of load: wire breakage tresholds: OFF condition: RLoad: typically > 5 kQ ON condition: ILoad typically < 500 mA additional overload protection by means of...

Open the catalog to page 2
PowerPlex® Power Module - 3

PowerPlex® Power Modul PP-M-DC024 Dimensions – Version 1 Mounting mounting bracket 2 (not included in delivery, see accessories) mounting bracket 1 (included in delivery) The module is designed for wall mounting by means of the fittings provided The module is designed for wall mounting by means of the fittings provided Installation drawings minus terminal (-) field for module address Installation drawings field for module adress strain relief snap-on cover This is a metric design and millimeter dimensions take precedence. Applicable for normal dimensions without direct tolerance indication:...

Open the catalog to page 3
PowerPlex® Power Module - 4

PowerPlex® Power Modul PP-M-DC024 Overview (without snap-on cover) space for module address label screw M3x8 max. tightening torque 80 Ncm L-profile strain relief Included in delivery: screw M3x8 L-profile centre mounting screw strain relief Caution: Mounting positions and sequence must be observed Typical time/current characteristics Programmable delay times available for overload tripping 25 ms*, 50 ms*, 100 ms, 200 ms, 500 ms, 750 ms*, 1 s*, 2 s*, 4 s*, 6 s* * not rececommended Ubat = 24 V, TA = 23 °C Curve 8 A, delay 100 ms

Open the catalog to page 4
PowerPlex® Power Module - 6

PowerPlex® Configuration Software USB/CAN converter: X PP-USBCO X PP-USBC1 (opto-decoupled) Mounting bracket 2: Y 310 292 01Circuit breakers for replacement 1610-21: 1610-21-10 A 1610-21-30 A Pin assignment D-SUB output plug This is a metric design and millimeter dimensions take precedence. Applicable for nominal dimensions without direct tolerance indication: DIN ISO 286 ± IT 13. Refer to product datasheet for installation and safety instructions. All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to...

Open the catalog to page 6

All E-T-A Elektrotechnische Apparate catalogs and brochures

  1. MPR10

    4 Pages

  2. SVS14

    6 Pages

  3. SVS15

    8 Pages

  4. SVS16

    6 Pages

  5. SVS18

    6 Pages

  6. SVS20

    8 Pages

  7. PP-M-PM024

    6 Pages

  8. PP-M-DC024

    6 Pages

  9. E-1048-8D...

    4 Pages

  10. 3131-A

    6 Pages

  11. ESR10

    4 Pages

  12. 1620

    2 Pages

  13. D_8340-G2

    5 Pages

  14. D_1120

    3 Pages

  15. D_1110

    2 Pages

  16. E-1048-8D

    3 Pages

  17. E-1048-8I

    5 Pages

  18. E-1048-8C.

    4 Pages

  19. 8340-F

    6 Pages

  20. 8340-G2

    5 Pages

  21. 1610-21

    3 Pages

  22. 1110

    2 Pages

Archived catalogs