Catalog excerpts
Description The PowerPlex® Panel Module has been designed for DC 12 V and DC 24 V on-board electrical systems of leisure boats and work boats. The module serves for the connection of up to 32 switches, with or without corresponding status indication via signalling LEDs. This allows easy integration of conventional switching panels with the benefits of a smart power distribution, control and monitoring. The patented Four Level Protection Concept (FLPC) offers redundant overload protection. In addition the E-T-A circuit breakers integrated in the Panel Modules allow manual activation of the 8 A outputs. PowerPlex® is a decentralised power distribution and control system. All PowerPlex® modules ensure reliable control and monitoring of the electrical installations on board, either alone or in combination with other PowerPlex® components. Besides the protection against overcurrent they allow readout of data of the connected level sensors and temperature sensors as well as of shunts. All modules of a system communicate and interact via an SAE-J1939-compliant CAN bus. PowerPlex® is configured by using the PowerPlex® Configuration Software and the configuration is transferred to the modules by means of USB/CAN converters. • watercraft, e. g. recreational, boats and work boats • special vehicles • well-proven CAN technology • redundant protection - Four Level Protection Concept (FLPC) • programmable overload protection • simple configuration • Windows based configuration software • integral diagnostic and monitoring functions • wire break detection • inputs for analogue sensors • dimming function (8 A outputs) • 32 digital inputs and 32 signal outputs Voltage rating UN DC 12 V / DC 24 V Max. total current per module 20 A Degree of Protection IP22 in a vertical mounting position with the main power connectors downwards Operating temperature range -40...+85 °C (-40...+185 °F) Storage temperature range -40...+85 °C (-40...+185 °F) Humid heat (IEC 60068-2-30, Db) 55 °C / 95 % RH, 24 hours 13.2 Hz to 100 Hz: acceleration 0.7 g Shock (IEC 60068-2-27, Ea) 30 g (11 ms) EMC CE marking to, The CAN-terminals at each end of the bus require a termination by a 120 Q resistor. Inputs 32 inputs for switches or momentary switches digital inputs: 0...50 Q: ON; > 100 kQ: OFF analogue input: Rin: 40 kQ; resolution: 10 bit Outputs 2 outputs with 8 A max. continuous current load output: Power MOSFET, high side switching adjustable from 1 A to 8 A in 1 A steps dimmable in 10 steps with 100 Hz PWM typical voltage drop UON at rated current (at 25 °C): 60 mV overload tripping range: 1.01...1.30 x IN trip time: adjustable from 100 msec to 6 s current limitation: typically 60 A at DC 24 V wire breakage monitoring in ON and OFF condition of load: wire breakage tresholds: OFF condition: RLoad: typically > 5 kQ ON condition: ILoad typically < 200 mA additional overload protection by means of one E-T-A circuit breaker type 1610-21-10 A per output Compliant with IEC 60533 Electrical and electronic installations in Ships - Electromagnetic compatibility
Open the catalog to page 1Technical data 4 outputs with max. 1 A continuous current load output: Power MOSFET, high side switching typical voltage drop UON at rated current (at 25 °C): 70 mV overload tripping range: > 4 A trip time: typically 2 ms at 10 A current limitation: typically 10 A at DC 24 V self-resetting 32 status outputs with integral LED driver, 150 Q / 5 V Status indications There are two LEDs on the top side of each module indicating module and system status. Signal output Configurable Signal Outputs: 32 status indicators (LEDs) can be configured to show the status of the load...
Open the catalog to page 2PowerPlex® Panel Modul PP-M-PM024 Dimensions – Version 1 mounting bracket 1 (included in delivery) mounting bracket 2 (not included in delivery, see accessories) The module is designed for wall mounting by means of the fittings provided The module is designed for wall mounting by means of the fittings provided Installation drawings minus terminal (-) field for module address Installation drawings field for module adress strain relief snap-on cover This is a metric design and millimeter dimensions take precedence. Applicable for normal dimensions without direct tolerance indication: DIN ISO...
Open the catalog to page 3PowerPlex® Panel Modul PP-M-PM024 Typical time/current characteristics Overview (without snap-on cover) Programmable delay times available for overload tripping space for module address label screw M3x8 max. tightening torque 80 Ncm strain relief 1610 30 A centre mounting screw Included in delivery: screw M3x8 L-profile strain relief Caution: Mounting positions and sequence must be observed 100 110 120 130
Open the catalog to page 4PowerPlex® Configuration Software USB/CAN converter: X PP-USBCO X PP-USBC1 (opto-decoupled) Mounting bracket 2: Y 310 292 01Circuit breakers for replacement 1610-21: 1610-21-10 A Pin assignment D-SUB output plug This is a metric design and millimeter dimensions take precedence. Applicable for nominal dimensions without direct tolerance indication: DIN ISO 286 ± IT 13. Refer to product datasheet for installation and safety instructions. All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes...
Open the catalog to page 6All E-T-A Elektrotechnische Apparate catalogs and brochures
-
High Power-D-Box®
4 Pages
-
Economy Power-D-Box®
4 Pages
-
PBM-1170-05-V0060
2 Pages
-
PBM-E1048-8..-B.-V0089
3 Pages
-
PowerPlex® Power Module
6 Pages
-
PowerPlex® Compact Module
6 Pages
-
MPR10
4 Pages
-
SVS14
6 Pages
-
SVS15
8 Pages
-
SVS16
6 Pages
-
SVS18
6 Pages
-
SVS20
8 Pages
-
PP-M-PM024
6 Pages
-
PP-M-DC024
6 Pages
-
E-1048-8D...
4 Pages
-
3131-A
6 Pages
-
ESR10
4 Pages
-
1620
2 Pages
-
PowerPlex® Touch Panel 4.3?
2 Pages
-
D_8340-G2
5 Pages
-
D_1120
3 Pages
-
D_1110
2 Pages
-
E-1048-8D
3 Pages
-
E-1048-8I
5 Pages
-
E-1048-8C.
4 Pages
-
8340-F
6 Pages
-
8340-G2
5 Pages
-
1610-21
3 Pages
-
1110
2 Pages