PBM-1170-05-V0060
2Pages

{{requestButtons}}

Catalog excerpts

PBM-1170-05-V0060 - 1

The power distribution system has been designed to accommodate plug-in type thermal circuit breakers type 1170-21, 1180 and 1610. It is a printed circuit board module for rail mounting. Typical applications are mainly in control cabinets for utility vehicles and special vehicles and for mobile construction machinery. The current supplied by a power supply is distributed onto 5 ways/ slots. There are two LEDs per circuit breaker. The red LED is lighted when the circuit breaker has tripped. The green LED is lighted when the circuit breaker is in ON condition. Group signalling is generated via the distributor. This signal can be enquired via a potential-free relay. The jumpers allow bridging the signalling for individual circuit breakers if those are not fitted. • Ease of cable management, reduced weight • The circuit breakers can be plugged in in OFF condition with the system live • One red and/or green LED per circuit breaker (ON/OFF) • Potential-free group signalling • Signalling can be bridged with a jumper in the event of empty slots • Other population versions available upon request Technical Data Dimensions including circuit breakers Rated voltage: Ordering information Load terminals: Type PBM power distribution 1170 thermal circuit breaker Version, max. number of circuit breakers on the power distribution system 05 number of slots 0060 Ausfuhrung Signalisation A Version A with signalling, red LED, 24 V DC B Version B with signalling, green and red LED, 24 V DC C Version C without signalling, without LED 12 V DC / 24 V DC D Version D with signalling, green and red LED, 12 V DC Group signalling: Temperature range: 12 V DC / 24 V DC 75 A spring-loaded terminal, a second terminal allows looping through 5 ways per max. 25 A 3 spring-loaded terminals per way changeover contact 0.5 A (12 V DC / DC 24 V) spring-loaded terminals -20 ... +70 °C pcb protected against condensation by surface coating Derating table temperature supply load output Note ambient Preferred types • The circuit breakers must only be plugged in or removed in the OFF condition. • The max. supply current of the individual printed circuit boards has to be observed when looping through several distribution modules. • The LEDs and the signalling require a mass potential (0 V), max. 2 A connected via spring-loaded terminals up to 2.5 mm2 (1.5 mm2 with wire end ferrule with plastic collar), a second terminal allows looping through. • Circuit breakers are not included in delivery. Overview of connections (terminals) Model

Open the catalog to page 1
PBM-1170-05-V0060 - 2

Power distribution system PBM-1170-05-V0060 Schematic diagram + symmetrical rail EN50022-35 x 7.5 (not part of the product) supply plus supply Gnd (0 V) signal terminal load terminals Plug-in modules (circuit breakers) have to be ordered separately.

Open the catalog to page 2

All E-T-A Elektrotechnische Apparate catalogs and brochures

  1. MPR10

    4 Pages

  2. SVS14

    6 Pages

  3. SVS15

    8 Pages

  4. SVS16

    6 Pages

  5. SVS18

    6 Pages

  6. SVS20

    8 Pages

  7. PP-M-PM024

    6 Pages

  8. PP-M-DC024

    6 Pages

  9. E-1048-8D...

    4 Pages

  10. 3131-A

    6 Pages

  11. ESR10

    4 Pages

  12. 1620

    2 Pages

  13. D_8340-G2

    5 Pages

  14. D_1120

    3 Pages

  15. D_1110

    2 Pages

  16. E-1048-8D

    3 Pages

  17. E-1048-8I

    5 Pages

  18. E-1048-8C.

    4 Pages

  19. 8340-F

    6 Pages

  20. 8340-G2

    5 Pages

  21. 1610-21

    3 Pages

  22. 1110

    2 Pages

Archived catalogs