High Power-D-Box®
4Pages

{{requestButtons}}

Catalog excerpts

High Power-D-Box® - 1

The Power-D-Box® is a compact 2U power distribution system made of aluminium in an enclosure with anodised front plate. Protection of the loads is by means of hydraulic-magnetic circuit breakers. Ordering information PDB Standard Power-D-Box® 19“ with interchangeable ETSI flange - 19“ *technical data on www.e-t-a.de High Power-D-Box® Technical data 19“ Power-D-Box® length 84 modules (426.72 mm) height 2 U (88.90 mm) material: aluminium Preferred types High Power-D-Box®: PDB - N - D 06 - RF: load current max. 65 A with 2 x 3 ways PDB - N - D 06 - RR: load current max. 125 A with 2 x 3 ways PDB - N - D 08 - RF: load current max. 65 A with 2 x 4 ways PDB - N - D 08 - RR: load current max. 125 A with 2 x 4 ways PDB - N - D 10 - RF: load current max. 65 A with 2 x 5 ways PDB - N - D 10 - RR: load current max. 85 A with 2 x 5 ways PDB - N - D 12 - RF: load current max. 65 A with 2 x 6 ways PDB - N - D 12 - RR: load current max. 85 A with 2 x 6 ways PDB - N - D 16 - RR: load current max. 6 x 85 A + 10 x 30 A Plug-in type circuit breakers 8345-.01A-W0..-DB1B2B-.. with and without auxiliary contact module X8345-S01KW102-M Rated voltage DC 48 V, DC 65 V, DC 80 V (other voltage ratings upon request) Total current per supply 125 A per plug-in unit (when using circuit breakers rated 80 A plus, total load of the neighbouring slots must not exceed 160 A) 232 A total current at ambient temperature -30...60 °C (-22 °F...140 °F) UL/CSA: 230 A total current at ambient temperature -30...+50 °C • Plug-in type circuit breakers, 8345-.01.-W0, extendable in service, with or without auxiliary contact, load per way 0.1.. .125 A • Extremely compact design (installation depth 310 mm) • Standard redundant design (2 x 3, 2 x 4, 2 x 6) • Group signalling for redundant line entry A and/or B is standard • To be used with industrially manufactured power distribution modules (X8345-D01), protected against brush contact • Labelling strips for individual marking • Blank covers (bulk shipped) • isolated cable clamp rail (X 223 260 01) optional as accessory • Integral jumper ground to plus pole (freely configurable by the customer as an option) • Other versions are available upon request (e.g. with series fuse, separate circuits, non-redundant circuits, customer-specific marking, protected plus pole etc.) Fire resistance (IEC 60695, part 2-2) Terminal design* Supply feed Signalling Ground Weight Conformity ‘(detailed values on page 4) self-extinguishing 35...95 mm2, flexible, screw-type terminal 25...95 mm2 with wire end ferrule 1.5...35 mm2, flexible, screw-type terminal 1.5...35 mm2 with wire end ferrule screw-type terminal 1.5 mm2 bolt (M8) approx. 7.5 Kg CE to EN60950-1 * depending on type, see preferred types max. total current of neighbouring channels 160A

Open the catalog to page 1
High Power-D-Box® - 2

Modular High Power-D-Box® Schematic diagrams High Power-D-Box load group A screw terminals max. 35 mm2 supply screw type terminals 95 mm2 screw terminals for front or rear side terminal terminal on the rear side Line C A5 Line C A6 Line C load group B screw terminals max. 35 mm2 screw terminals for front or rear side terminal terminal on the rear side

Open the catalog to page 2
High Power-D-Box® - 3

Modular High Power-D-Box® Dimensions optional cable clamp rail 531.4 (ETS) 20.9 Load terminals front cable guiding operation area screw driver optional isolated cable clamp rail Load terminals rear operation area ratchet wrench hexagon socket screw optional isolated cable clamp rail cable guiding

Open the catalog to page 3
High Power-D-Box® - 4

Cable clamp rail X 223 260 01 consisting of 2 mounting brackets 1 rod 6 screws 1 Insulating sleeve Grounding connector incl. mounting material (connection plus to earth) X 223 259 01 consisting of: 2 grounding connectors 4 nuts All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted.

Open the catalog to page 4

All E-T-A Elektrotechnische Apparate catalogs and brochures

  1. MPR10

    4 Pages

  2. SVS14

    6 Pages

  3. SVS15

    8 Pages

  4. SVS16

    6 Pages

  5. SVS18

    6 Pages

  6. SVS20

    8 Pages

  7. PP-M-PM024

    6 Pages

  8. PP-M-DC024

    6 Pages

  9. E-1048-8D...

    4 Pages

  10. 3131-A

    6 Pages

  11. ESR10

    4 Pages

  12. 1620

    2 Pages

  13. D_8340-G2

    5 Pages

  14. D_1120

    3 Pages

  15. D_1110

    2 Pages

  16. E-1048-8D

    3 Pages

  17. E-1048-8I

    5 Pages

  18. E-1048-8C.

    4 Pages

  19. 8340-F

    6 Pages

  20. 8340-G2

    5 Pages

  21. 1610-21

    3 Pages

  22. 1110

    2 Pages

Archived catalogs