Catalog excerpts
Thermal Overcurrent Circuit Breaker 1110-... Description Tease-free, trip-free, snap action mechanism. Designed for snap-in panel mounting utilising round hole or industry standard fuse-holder cut-out dimensions. Featuring an ergonomically styled two colour actuator with indicator band clearly showing the tripped/OFF position. Approved to CBE standard EN 60934 (IEC 60934): S-type TO CBE Typical applications Motors, transformers, solenoids, extra low voltage systems, household and office machines, instrumentation, marine applications, mobile homes. 1110-F1.. Ordering information Type No. 1110 snap in panel mounting Mounting F1 panel thickness 0.8...1.6 mm (.031 -.063 in) F2 panel thickness 1.8...3 mm (.071-.118 in) Number of poles 1 1-pole protected Actuator style 2 black push button/white indicator ring, push-push function Terminal design P1 blade terminals A6.3-0.8 (QC .250) Characteristic curve M1 medium delay Current ratings 0.05...16A For further details please see chapter: Technical Information Voltage rating AC 250 V; DC 50 V Current rating 0.05...16 A Typical life In 1xIn 10,000 DC 28 V 1xIn 6,000 DC 50 V 1xIn 12...16 A 2,000 DC 50 V 1xIn Ambient temperature Insulation co-ordination (IEC 60664 and 60664 A) Standard current ratings (A) 1 1.5 2 3 3.5 4 5 6 7 8 10 15 16 x x x x x x x x x x x x x x x I AC 250 V 0.05...10 A NEW x Un 10,000 0.05...10 A Preferred types 1110-F112-P1M11110-F212-P1M1- operations 0.05...10 A 1110 - F1 1 2 - P1 M1 - 0.05 A = ordering example Preferred types 2 Technical data x x x x x Dielectric strength (IEC 60664 and 60664A) operating area Insulation resistance Interrupting capacity Icn x Standard current ratings and typical internal resistance values Interrupting capacity (UL 1077/EN60934 PC 1) Current rating (A) Internal resistance (Ω) Current rating (A) Internal resistance (Ω) 0.05 442 2 0.25 0.08 173 2.5 0.19 0.1 110 3 0.12 0.2 27.8 3.5 0.09 0.3 12.4 4 0.07 0.4 7.0 5 0.05 Humidity 0.5 4.5 6 0.04 Mass 0.6 3.1 7 2.3 8 ≤ 0.02 0.8 1.7 10 ≤ 0.02 1 1.1 12 ≤ 0.02 1.2 0.71 15 ≤ 0.02 1.5 0.41 16 ≤ 0.02 1.8 0.38 test voltage AC 3,000 V > 100 MΩ (DC 500 V) AC 250 V: 0,05...10 A 8 x IN DC 50 V: 0,05...6.5 A 65 A 7...16 A 130 A DC 28 V: 7...10 A 200 A UN IN 0.05...6 A AC 250 V 1,000 A 7...16 A AC 125 V 1,000 A 0.05...16 A DC 50 V 1,000 A operating area IP40 terminal area IP00 8 g (57-500 Hz) ± 0.61 mm (10-57 Hz), to IEC 60068-2-6, test Fc, 10 frequency cycles/axis 30 g (11 ms) to IEC 60068-2-27, test Ea 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka 240 hours at 95 % RH to IEC 60068-2-78, test Cab approx. 12 g ≤ 0.02 0.7 -20...+60 °C (-4...+140 °F) rated impulse pollution withstand voltage degree 2.5 kV 2 reinforced insulation in operating area Degree of protection (IEC 60529/DIN 40050) Vibration Shock Corrosion Issue D (060212) Approvals Authority Voltage ratings Current ratings VDE AC 250 V; DC 50 V 0.05...10 A 0.05...16 A UL/CSA AC 250 V AC 125 V DC 50 V 0.05...6 A 0.05...16 A 0.05...16 A www.e-t-a.de 2 - 29
Open the catalog to page 1Thermal Overcurrent Circuit Breaker 1110-... Dimensions Internal connection diagram 1 1110-F1.. / -F2.. 19 .748 10 .394 19 .748 10 .394 black white 2.4 .094 15 .591 9.5 .374 ON OFF When installing the circuit breaker apply pressure on bezel only. 2 51 2.01 47.5 1.85 Typical time/current characteristics at +23 °C/+73.4 °F 2 10000 0.05 - 6 A 12.5 .492 9 .354 7 - 16 A 1000 12.1 .476 15.6 .520 .614 blade terminals DIN 46244-A6.3-0.8 (QC .250) 10 +0.2 - 0.4 +.008 - .016 ±0.05 ±.002 0.8 … 1.6 .031 … .063 insertion force ≤ 20 N, removal force ≥ 120 N 1 +0.2 - 0.4 +.008 - .016 installation side...
Open the catalog to page 2All E-T-A Elektrotechnische Apparate catalogs and brochures
-
High Power-D-Box®
4 Pages
-
Economy Power-D-Box®
4 Pages
-
PBM-1170-05-V0060
2 Pages
-
PBM-E1048-8..-B.-V0089
3 Pages
-
PowerPlex® Power Module
6 Pages
-
PowerPlex® Panel Module
6 Pages
-
PowerPlex® Compact Module
6 Pages
-
MPR10
4 Pages
-
SVS14
6 Pages
-
SVS15
8 Pages
-
SVS16
6 Pages
-
SVS18
6 Pages
-
SVS20
8 Pages
-
PP-M-PM024
6 Pages
-
PP-M-DC024
6 Pages
-
E-1048-8D...
4 Pages
-
3131-A
6 Pages
-
ESR10
4 Pages
-
1620
2 Pages
-
PowerPlex® Touch Panel 4.3?
2 Pages
-
D_8340-G2
5 Pages
-
D_1120
3 Pages
-
E-1048-8D
3 Pages
-
E-1048-8I
5 Pages
-
E-1048-8C.
4 Pages
-
8340-F
6 Pages
-
8340-G2
5 Pages
-
1610-21
3 Pages
-
1110
2 Pages