P-Bond 50 - Full Description
29Pages

{{requestButtons}}

Catalog excerpts

P-Bond 50 - Full Description - 3

Two-component epoxy-based adhesive system. Room temperature curing 2:1 mixing ratio system performing bondlines with high mechanical strength. The adhesive system is slow curing with satisfactory use in any environmental condition, even underwater. 00 High Viscosity CO Super structural 00 Solvent-Free CO Multi-material bonding CO Dark coloured aging resistant CO Non-sagging 00 Construction 00 Industrial Processes

Open the catalog to page 3
P-Bond 50 - Full Description - 4

SYSTEM INSIGHTS ONE4ALLCURING PERFORMANCE Working Life (min) Tack Free Time (min) Full Cured Time (hours) Tensile Elongation (%) Hardness Shore A (ASTM 2204) Glass Transition Temperature (Tg), °C

Open the catalog to page 4
P-Bond 50 - Full Description - 5

ALL PURPOSE MARINE ADHESIVE

Open the catalog to page 5
P-Bond 50 - Full Description - 6

ALL THE INFO SHOWN REFERS TO STANDARD CHEMISTRY PRODUCTS AVAILABLE ON THE MARKET

Open the catalog to page 6
P-Bond 50 - Full Description - 7

□r saiLS“ TECHNICALDATA S1201 SYSTEM PRODUCT DESCRIPTION P-BOND is a two-component super strong epoxy based adhesive system capable to cure in the most extreme conditions, even underwater. Once mixed is a very low sagging, high viscosity system that reaches high strength bond to almost all materials performing high structurability. Last Review: JULY 2018 Curing Properties (Air/water @ 252C unless noted) Typical Value Working Life , minutes 20 Tack Free Time,hours 4 Full Cured Time, hours 24 TYPICAL APPLICATIONS Ideal for high strength bonding a full range of materials: metals, wood,...

Open the catalog to page 7
P-Bond 50 - Full Description - 8

Information given in the Material Safety Data Sheet is drafted in accordance with COMMISSION REGULATION (EU) 2015/830 of 28 May 2015. See the Material Safety Data Sheet for details. Thermal degradation Test Procedure: MidPoint degradation: Directions for use I.For high strength structural bonds, removal of surface contaminates such as paint, oxide films, oils, dust, mold release agents and all other surface contaminates. 2.Use gloves to minimize skin contact. DO NOT use solvents for cleaning hands. 3.Syringe container: Syringe ensures correct mixed ratio of the two components. Remove the...

Open the catalog to page 8
P-Bond 50 - Full Description - 9

□r saiLS“ TECHNICALDATA S1201 SYSTEM Last Review: JULY 2018 Sailing Technologies specifically disclaims all warranties expressed or implied, including warranties of merchantability or fitness for a particular purpose, arising from sale or use of Sailing Technologies’ products. Sailing Technologies specifically disclaims any liability for consequential or incidental damages of any kind, including lost profits. The discussion herein of various processes or compositions is not to be interpreted as representation that they are free from domination of patents owned by others or as a license...

Open the catalog to page 9
P-Bond 50 - Full Description - 10

Page 1 of 10 Print date: 04/04/2019 SAFETY DATA SHEET (in accordance with Regulation (EU) 2015/830) P-BOND (Component A) Version: 1 Revision date: 04/04/2019 1.1 Product identifier. Product Name: P-Bond (component A) 1.2 Relevant identified uses of the mixture and uses advised against. Adhesive Uses advised against: Uses other than those recommended. 1.3 Details of the supplier of the safety data sheet. Company: Sailing Technologies, S.L. Address: C/ CALATRAVA N° 68, BAJOS 3 Province: BARCELONA E-mail: info@glooers.com 1.4 Emergency telephone number: +34 932 693 348 (Only available during...

Open the catalog to page 10
P-Bond 50 - Full Description - 11

SAFETY DATA SHEET (in accordance with Regulation (EU) 2015/830) P-BOND (Component A) Version: 1 Revision date: 04/04/2019 EUH statements: EUH205 Contains epoxy constituents. May produce an allergic reaction. Contains: Polipropilenglicol alquilfenil-eter epoxy resin (number average molecular weight < 700),reaction product: bisphenol-A-(epichlorhydrin) Formaldehyde, oligomeric reaction products with 1-chloro-2,3-epoxypropane and phenol 2.3 Other hazards. In normal use conditions and in its original form, the product itself does not involve any other risk for health and the environment....

Open the catalog to page 11
P-Bond 50 - Full Description - 12

SAFETY DATA SHEET (in accordance with Regulation (EU) 2015/830) P-BOND (Component A) Version: 1 Revision date: 04/04/2019 Page 3 of 10 Print date: 04/04/2019 In case of doubt or when symptoms of feeling unwell persist, get medical attention. Never administer anything orally to persons who are unconscious. Inhalation. Take the victim into open air; keep them warm and calm. If breathing is irregular or stops, perform artificial respiration. Eye contact. Remove contact lenses, if present and if it is easy to do. Wash eyes with plenty of clean and cool water for at least 10 minutes while...

Open the catalog to page 12
P-Bond 50 - Full Description - 13

SAFETY DATA SHEET (in accordance with Regulation (EU) 2015/830) P-BOND (Component A) Version: 1 Revision date: 04/04/2019 6.3 Methods and material for containment and cleaning up. Pick up the spill with non-combustible absorbent materials (soil, sand, vermiculite, diatomite, etc.). Pour the product and the absorbent in an appropriate container. The contaminated area should be immediately cleaned with an appropriate de-contaminator. Pour the decontaminator on the remains in an opened container and let it act various days until no further reaction is produced. 6.4 Reference to other sections....

Open the catalog to page 13
P-Bond 50 - Full Description - 14

Page 5 of 10 Print date: 04/04/2019 SAFETY DATA SHEET (in accordance with Regulation (EU) 2015/830) P-BOND (Component A) Version: 1 Revision date: 04/04/2019 Characteristics: CEN standards: Maintenance: Observations: Filter Type needed: Hand protection: «CE» marking, category III. The mask must have a wide field of vision and an anatomically designed form in order to be sealed and watertight. Should not be stored in places exposed to high temperatures and damp environments before use. Special attention should be paid to the state of the inhalation and exhalation valves in the face adaptor....

Open the catalog to page 14
P-Bond 50 - Full Description - 15

SAFETY DATA SHEET (in accordance with Regulation (EU) 2015/830) P-BOND (Component A) Version: 1 Revision date: 04/04/2019 Upper Explosive Limit: N.A./N.A. Vapour pressure: < 0.0002 kPa Vapour density:N.A./N.A. Relative density:1.17 g/cm3 Solubility:N.A./N.A. Liposolubility: N.A./N.A. Hydrosolubility: Practically insoluble Partition coefficient (n-octanol/water): N.A./N.A. Auto-ignition temperature: N.A./N.A. Decomposition temperature: > 200 °C°C Viscosity: 25000-45000 Explosive properties: N.A./N.A. Oxidizing properties: N.A./N.A. N.A./N.A.= Not Available/Not Applicable due to the nature of...

Open the catalog to page 15

All DrSails catalogs and brochures

  1. DrSails 400

    3 Pages

Archived catalogs

  1. DrSails 10

    3 Pages

  2. DrSails 265

    3 Pages