Overview: The document outlines the specifications and descriptions of explosion-proof lighting and equipment designed for hazardous areas, manufactured by DOSE. These products are named after famous harbors and comply with ATEX 100 standards, ensuring safety and reliability in challenging environments.
Product Specifications:
  • Hamburg LXH500: A 500W explosion-proof halogen floodlight with aluminum housing and borosilicate glass, suitable for temperatures between -20°C and +40°C, certified under BVS 09 ATEX E 50 x.
  • Rotterdam EXL218 & EXL236: Fluorescent light fittings with IP66 protection, available in 2x18W and 2x36W, suitable for temperatures from -25°C to +50°C, certified under BVS 09 ATEX E 147, 162.
  • Palux BRL20 Ex: An 18W battery room light with aluminum housing and polycarbonate cover, IP56/68 rated, certified under PTB 03 ATEX 2156.
  • Hongkong 505: A 60W explosion-proof light with brass casing and ex-glass, certified under PTB 03 ATEX 2077X.
  • Port Said 504LED: A 10W LED light with red cast brass casing, certified under PTB 06 ATEX 1046 X.
  • Wellington 3312: A 200W explosion-proof light with brass casing and glass ring, certified under PTB 03 ATEX 1111.
  • Acapulco LED 5062: A 2W explosion-proof LED light with brass casing and clear cylindrical glass, certified under PTB 14 ATEX 1007.
  • Shanghai 510: An explosion-proof junction box with brass casing, suitable for up to 750V and 32A, certified under PTB03 ATEX 1043x.
Key Features:
  • Designed to withstand harsh conditions and tested to the highest standards.
  • Suitable for use in hazardous areas, providing safety and reliability.
  • Available with various certifications ensuring compliance with international safety standards.
Applications: Ideal for environments with explosive gases or dust, such as marine, industrial, and offshore settings.
Additional Equipment Specifications:
  • Explosion-proof Rotary Switch (Singapur 514): Brass casing, IP 56 protection, 2-pole cut-out type, supports up to 660V AC and 16A, ex-protection class EEx de IIC T6.
  • Explosion-proof CEE-Sockets and Plug (Busan 516): Brass casing, IP 56 protection, supports up to 240V AC and 16A, ex-protection class EEx ed IIC T6/T5.
Spare Parts: Includes ex-terminal blocks, inner hexagonal keys, and ex-switch interiors with respective weights and descriptions.
Standards and Certifications:
  • Compliance with ATEX directive 94/9/EC for explosive atmospheres.
  • Certified by PTB and possibly by German Lloyd (GL) and other classification societies.
Protection Types:
  • Increased Safety ‘e’ (EN 50019): Prevents high temperatures and spark generation.
  • Pressure-Resistant Enclosure ‘d’ (EN 50018): Contains potential explosions within a sealed enclosure.
Temperature Ranges: Specifies maximum surface temperatures for different temperature classes (T1 to T6), ranging from 450°C to 85°C.
IP Code Protection: Details degrees of protection against solid objects and water, from non-protected to dust-tight and protected against continuous immersion in water.
Additional Information: Emphasizes the importance of selecting materials according to protection guidelines and provides a brief on the classification of hazardous areas.
See more

Catalog excerpts

Equipment for hazardous areas-1

At home in a safe harbour! Every sailor is happy, if he can rescue himself and his ship into a safe harbour from a storm. With the explosion proof DOSE products you won’t even run into danger. To be able to withstand all odds, our products were and still are tested to the highest standards. With DOSE you are always at home in a safe harbour. DOSE products in accordance with ATEX 100 are named by famous harbours. Hamburg is one of them.

 Open the catalog to page 1
Equipment for hazardous areas-2

Spare Parts Port Said

 Open the catalog to page 2
Equipment for hazardous areas-3

Technical Data Name & No. • IP 67 • plastic cable gland: M25x1.5 and 1 x blind plug M25x1.5 • without lamp • Ex-proof floodlight for halogen lamps 500W (230/240V) with lampholder E40. Housing, glass-holding frame and bracket made of aluminium, special paint finish in grey colour. Glas holding frame with sealed borosilicate glass, with stainless steel screws (undetachable) • hinged glass holding frame. Separate Ex-e terminal box with 1x M25 plastic cable gland and cable gland: M25 plastic blind plug • 230V +/- 10% • 50 / 60 Hz • permissable ambient temperature: -20°C to +40°C. Insulation class:...

 Open the catalog to page 3
Equipment for hazardous areas-4

Technical Data Name & No. • IP 66 • housing, glass-holding frame and bracket made of aluminium, special paint finish in grey colour. • plastic cable gland: M25x1.5 and 1 x blind plug M25x1.5 • without lamp • hinged glass holding frame with sealed borosilicate glass, with stainless steel screws (undetachable). Ballast unit and ignitor isolated from the lamp in a seperate compartment, thus ensuring that the heat of the lamp does not have any harmful effects. Ballast fittet with connection plug to allow easy removal for servicing purposes • lampholder: E40 • 230V +/- 10% • 50 / 60 Hz • permissible...

 Open the catalog to page 4
Equipment for hazardous areas-5

Ex Fluorescent Light Fittings 2x18W Technical Data Name & No. • IP 66 • housing made of glass mat reinforced polyester, protective cover made of polycarbonate, plastic cable gland • cable gland: M25x1.5 • incl. lamp • 50 / 60 Hz • ex-protected fluorescent light fitting with 2 channel electronic ballast unit for bi-pin fluorescent lamps (G13) 2x18W. Double-sided lock with 10 latch points. Protective cover hingeable on both sides. Automatic switch built as a safety disconnector acc. to EN 60947. Automatic switch ensuring the disconnection of all exposed components when the fitting is opened. Large...

 Open the catalog to page 5
Equipment for hazardous areas-6

Ex Fluorescent Light Fittings 2x36W Technical Data Name & No. • IP 66 • housing made of fibre glass reinforced polyester, protective cover made of polycarbonate, plastic cable gland • plastic cable gland: M25x1.5 • without lamp • 50 / 60 Hz • ex-protected fluorescent light fitting with 2 channel electronic ballast unit for bi-pin fluorescent lamps (G13) 2x36W. Double-sided lock with 20 latch points. Protective cover hingeable on both sides. Automatic switch built as a safety disconnector acc. to EN 60947. Automatic switch ensuring the disconnection of all exposed components when the fitting is...

 Open the catalog to page 6
Equipment for hazardous areas-7

Ex Emergency Light Fittings 2x18W Technical Data Name & No. • IP 66 • housing made of fibre glass reinforced polyester, protective cover made of polycarbonate, plastic cable gland • plastic cable gland: M25x1.5 • without lamp • 50 / 60 Hz • ex-protected fluorescent light fitting with 2 channel electronic ballast unit for bi-pin fluorescent lamps (G13) 2x18W. Double-sided lock with 10 latch points. Protective cover hingeable on both sides. Automatic switch built as a safety disconnector acc. to EN 60947. Automatic switch ensuring the disconnection of all exposed components when the fitting is...

 Open the catalog to page 7
Equipment for hazardous areas-8

Ex Emergency Light Fittings 2x36W Technical Data Name & No. • IP 66 • housing made of fibre glass reinforced polyester, protective cover made of polycarbonate, plastic cable gland • plastic cable gland: M25x1.5 • without lamp • 50 / 60 Hz • ex-protected fluorescent light fitting with 2 channel electronic ballast unit for bi-pin fluorescent lamps (G13) 2x36W. Double-sided lock with 20 latch points. Protective cover hingeable on both sides. Automatic switch built as a safety disconnector acc. to EN 60947. Automatic switch ensuring the disconnection of all exposed components when the fitting is...

 Open the catalog to page 8
Equipment for hazardous areas-9

Ex-proof Battery Room Light Technical Data Name & No. • IP 56 / 68 • housing aluminium, light cover temperature change-steady polycarbonate pipe • cable gland: M18x1.5 chome-plated acc. DIN 89280 • supply with pipe clamps, electronic ballast unit, lampholder and lamp • 86-240V AC, 154-240V DC • 50 / 60 Hz • powder coated RAL 9010 • ex-protection class: EEx ed IIC T4, PTB-No.: PTB 03 ATEX 2156. The light is amagnetic, shock (acc. BV043) and EMV examined. Enviromental temperature -20°C to 45°C.

 Open the catalog to page 9
Equipment for hazardous areas-10

polished version polished version polished version Technical Data Name & No. • IP 56 • brass casing and guard, ex-glass, resistant against temerature changes • cable gland: M24x1.5 • without lamp • incl. Ex-lampholder, pressure resistant enclosure and security screw for guard • explosion-proof light for bulb DIN 49810 part 5, max 60W, PTB-No. PTB 03 ATEX 2077X • ex-protection class: EEx ed IIC T3 60W/220V), EEx ed IIC T4 (25W) ), EEx ed IIC T2 (only shock protection lamp 130V/60W Merkur hangig mounting) Ex-lampholder E27, pressure resistant enclosure Polished products available for a extra charge...

 Open the catalog to page 10
Equipment for hazardous areas-11

Port Said karl-dose.de/Port Said polished version economical durable powerful Technical Data Wattage • IP 56 • red cast brass casing and guard, glass clear • cable gland: M20x1,5, on request M25x1,5 • incl. LED • PTB 06 ATEX 1046 X. Ex protection class: Eex de IIC T6, pressure resistant. • certified according to EN 60079-0-2009 • IP 56 • red cast brass casing and guard, glass clear • cable gland: M20x1,5, on request M25x1,5 • incl. lamp (60W or 100W) • 230V • explosion-proof light PTB 06 ATEX 1046 X. Pressure resistant enclosure. Temperatur class depends on installation. • IP 56 • red cast brass...

 Open the catalog to page 11

All Dose catalogs and brochures

  1. Navy Equipment

    52  Pages

  2. Ship lighting

    38  Pages

  3. KARL DOSE 2024

    174  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.