IR-10

IR-10

IR-10

Product catalog summary
General Overview
The DETEGASA Delta Incinerator Model IR-10 is designed and manufactured to meet the requirements of Classification Societies and IMO/MARPOL 73/78 Annex V, which addresses pollution by garbage from ships.
Scope of Supply
The standard supply includes a complete incinerator package with components mounted on a baseplate, such as the incinerator, D.O. burner, control panel, and instrumentation. Additionally, loose components like the exhaust gas fan, exhaust gas regulating damper, and a thermocouple for installation in the exhaust gas pipe are provided.
Main Technical Characteristics
  • Maximum capacity: 100,000 Kcal/h
  • Solid waste burning capacity: 25 kg/h (3600 kcal/kg)
  • Combustion chamber max temperature: 1200ºC
  • Exhaust gas temperature max: 350ºC
  • Depression in combustion chamber: -25 mm.w.g.
  • Max temperature of enclosure: 60ºC
  • Auxiliary burner max consumption: 8.5 kg/h
  • D.O. viscosity: 13 CST at 50ºC
  • D.O. burner electric motor: 185 W
  • Exhaust gas fan motor: 380 V 50 Hz 4 KW / 440 V 60 Hz 4.8 KW
  • Pressure loss through the incinerator: 80 mm.w.g.
  • Radiated noise level: 85 dB
  • Exhaust gas quality: According to IMO MEPC76 (40)
Drawing List
The document includes references to various drawings such as general arrangements and interfaces, flue gas fan main dimensions, regulating damper, and flow diagrams.
See more

Catalog excerpts

IR-10-1

DELTA INCINERATOR MODEL IR-10 MARINE INCINERATOR "DELTA" TYPE IR-10 TECHNICAL SPECIFICATION GENERAL Equipment submited in this quotation is designed and manufactered in accordance to Classification Societies requeriments and those of IMO/MARPOL 73/78 Annex V “Pollution by Garbage from Ships” SEE “MAIN TECHNICHAL CHARACTERISTICS DATA SHEET” ENCLOSED SCOPE OF SUPPLY Our standard scope of supply include: Item 1 - Incinerator package complete including the following components mounted in a baseplate. ! Incinerator. ! D.O. Burner. ! Control panel and instrumentation. Item 2 Also supplied as loose components. ! Exhaust Gas Fan. ! Exhaust Gas regulating damper. ! Thermocouple to install in the exhaust gas pipe 2.5 meters from the Incinerator Exhaust Gas outlet. DESARROLLOS TECNICAS INDUSTRIALES DE GALICIA, S.A. (D.E.T.E.G.A.S.A.) Address: CTRA. CASTRO / MEIRAS, VALDOVIÑO, 15550 LA CORUÑA, SPAIN P.O. BOX: 566 - 15480 EL FERROL - (LA CORUÑA) - SPAIN PHONE: +34-981-485444 FAX: +34-981-486352 [email protected] [email protected] www.detegasa.com

 Open the catalog to page 1
IR-10-2

DELTA INCINERATOR MODEL IR-10 MAIN TECHNICAL CHARACTERISTICS Maximum capacity Based on the a.M. Calorific capacity, the following quantities can be burnt. 100000 Kcal/h. Solid Waste Combustion chamber max. Temperature Depression in Combustion Chamber Auxilliary Burner max. Consumption D.O D,O, Burner electric motor installed Pressure Loss through the Incinerator Radiated Noise Level DRAWING LIST GENERAL ARRANGEMENTS AND INTERFACES . . . . . . . . . . . . . . IN-010B-GO1I FLUE GAS FAN MAIN DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . IN-010VR-G01I REGULATING DAMPER . . . . . . . ....

 Open the catalog to page 2
IR-10-3

DESARROLLO TECNICAS "DELTA" SOLID WASTE GENERAL ARRANGEMENT & INTERFACES

 Open the catalog to page 3
IR-10-4

DESARROLLO TECNICAS "DELTA" SOLID WASTE REGULATING DAMPER

 Open the catalog to page 4
IR-10-6

DESARROLLO TECNICAS "DELTA" SOLID WASTE FLOW DIAGRAM

 Open the catalog to page 6
IR-10-7

DESARROLLO TECNICAS DELTA SOLID WASTE FLOW DIAGRAM SCOPE SUPPLY

 Open the catalog to page 7
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.