D90 - D 280 REMOTE CONTROL
22Pages

{{requestButtons}}

Catalog excerpts

D90 - D 280 REMOTE CONTROL - 1

USER'S MANUAL Mini remote control REMOTE CONTROL VERSION COMPACT VERSION Technical and Sales Departments: Z.I des 3 Moulins - « Euro 92 » - Bât. D - rue des Cistes - 06600 ANTIBES e-mail: contact@dessalator.com

Open the catalog to page 1
D90 - D 280 REMOTE CONTROL - 2

Remote control - Horizontal version page 1 Remote control-Vertical version page 2 Integrated control - Compact version page 3 2. Components supplied by DESSALATOR page 4 3.1 Sea water inlet valve and filters page 5 3.2 Pre-pump and high pressure switch page 6 3.4 Control panels page 8 3.5 Motor unit page 9 3.6 Connection plans 22ovoits I/F BOX (Provisionai) Rev.o.2 21/06/07 page 1 0 3.7 High pressure connectors page 12 5. Reverse osmosis principle page 14 6.1 Cleaning the membranes page 16 6.2 Sterilizing the membranes page 17 7. Instructions for sterilisation of cartridges page 18 8....

Open the catalog to page 2
D90 - D 280 REMOTE CONTROL - 6

_ACCORDING TO WATERMAKER TYPE: Hull valve: The VA hull valve strainer filters out the larger particles Pre-pump: (with exception of "Solo" model) Fixed under the waterline it enables water to flow through the pre-filters to the HP motor unit. Pre-filters (One filter for "solo" model): The first 25um cartridge filters out rough particles and the second 5um cartridge refines the treatment. For automatic rinsing an electro-valve is mounted. Motor unit: HP motor unit either in compact frame or with remote control. It allows water to be pressurised to 60-65 bars. Motor with integrated control...

Open the catalog to page 6
D90 - D 280 REMOTE CONTROL - 7

DESALINATOR 90 TO 280 LITRES / HOUR Sea water inlet valve %: The sea water inlet valve should be positioned as low as possible below the waterline and should be accessible. The grooves on the strainer should be facing forward (towards the bow) for maximum water intake when the boat is moving forward. The underwater installation should be sealed with Rubson or Sicaflex. The valve and the hose connector can be installed using a tube made watertight with 577 loctite The sea water inlet valve should be connected to the pre-filter using a Tricoflex hose 19 mm inner diameter, with 2 stainless...

Open the catalog to page 7
D90 - D 280 REMOTE CONTROL - 8

DESALINATOR 90 TO 280 LITRES / HOUR The pre-pump with its rinse valve3 (with exception of "Solo" version) should be installed as low as possible in the boat and should be easily accessible. The pressurised fresh water pipe should be connected to the valve to facilitate rinsing the desalinator. See water and electricity connection plan enclosed (page 10). Recommendation: Remember to attach two stainless jubilee clips to each joint. THE PUMP SHOULD NOT BE PLACED WHERE THERE IS A RISK OF WATER SPRAY. Pump cable case 220V Pump cable case 380V CAUTION: POWER SUPPLY SHOULD BE SWITCHED OFF BEFORE...

Open the catalog to page 8
D90 - D 280 REMOTE CONTROL - 9

DESALINATOR 90 TO 280 LITRES / HOUR Membrane(s) according to desired water flow: 1 membrane for 90 litres / hour water production 2 membranes for 160 litres / hour water production 3 membranes for 200 litres / hour water production 4 membranes for 280 litres / hour water production The membranes can be installed either vertically or horizontally. They are mounted using 4 Parker screws in alloy brackets1. The number of membranes used depends on the desired water flow. Hose from the HP pump should join the membranes at the red ring2. As the hose from the HP pump vibrates, it is preferable...

Open the catalog to page 9
D90 - D 280 REMOTE CONTROL - 10

DESALINATOR 90 TO 280 LITRES / HOUR Control panels in accordance with your watermaker version: Horizontal version: Vertical Version: Front panel Back panel Front panel Compact version: Back panel Front panel Back panel Mini remote control All remote control panels must be mounted on a vertical surface. Installing the panels close to the watermaker system facilitates the piping and hose connections. Mini remote control: Optional extra which allows starting and shutting down the desalinator without using the general control panel. Figures for each connection are as follows: (see diagrams page...

Open the catalog to page 10
D90 - D 280 REMOTE CONTROL - 11

DESALINATOR 90 TO 280 LITRES / HOUR There are three water connections to the pump head: - A 15mm diameter pipe1 from the pre-filters. - A HP hose2 to the 8mm diameter membranes (see installation - A capillary 3mm diameter tube3: this must be clipped into its connector. To remove it, just push the black ring and remove at the same time. The HP unit should be installed in a horizontal position and must be protected from water spray. Connections are illustrated Additional hardware needed for assembly: - miscellaneous screws (including Parker) - assortment of stainless jubilee clips 10mm, 16mm...

Open the catalog to page 11
D90 - D 280 REMOTE CONTROL - 14

DESALINATOR 90 TO 280 LITRES / HOUR 3.7 INSTALLATION INSTRUCTIONS - HP CONNECTORS 1. Screw the brass union (skirt) anti-clockwise onto the HP pipe, no more than 2.5cm. Stop where the inner threading disappears. 2. Insert the steel tapered end-piece into the stainless steel nut, and tighten very firmly on the male tapered union. 3. Lightly grease the tip of the stainless steel cone and screw it perfectly straight into the brass union. Stop where the steel threading disappears into the brass end-piece (a gap of approximately 7mm between the nut and the brass union)

Open the catalog to page 14
D90 - D 280 REMOTE CONTROL - 15

1. Ensure the valves are open before starting up the desalinator. 2. If the desalinator has not been run for several days, rinse with the three-way valve on the pre-pump as for normal rinsing before use. This should be carried out while the desalinator is idle and with the pressure regulator open (fully anti- clockwise). Rinse for two minutes. 3. To start the desalinator the first time, the pressure regulator must be open. Switch the interrupter of the main control panel on and give a quarter turn to impulse it: the low pressure pump will start than the high pressure pump will automatically...

Open the catalog to page 15
D90 - D 280 REMOTE CONTROL - 16

5. REVERSE OSMOSIS PRINCIPLE What is the reverse osmosis principle used in your desalinating system? Sea water is forced at high pressure through the membranes which act as "molecular sieves", only allowing pure fresh water to pass through. Most dissolved solid particles will not penetrate the membranes. This waste, along with the remaining saline solution, will flow on the surface of the membranes and will be rejected. Not all particles dissolved in sea water can be eliminated. The system is designed to reject 99% of the TDS (Totally Dissolved Solids); approximately 2% of the 35,000...

Open the catalog to page 16

All Dessalator catalogs and brochures

  1. DC Freedom 60

    21 Pages

  2. DC Freedom 30

    22 Pages

  3. AC CRUISE 60

    1 Pages

  4. Freedom 100

    1 Pages

  5. D2000 SPE

    1 Pages

Archived catalogs

  1. DUO 100

    21 Pages

  2. DUO 60

    21 Pages

  3. D 60

    22 Pages

  4. D 100

    21 Pages

  5. D440-D1000

    16 Pages

  6. D 90 TO D 280

    21 Pages

  7. SOLO 100

    19 Pages

  8. SOLO 60

    19 Pages