OptiSave - Energy Saving System
20Pages

{{requestButtons}}

Catalog excerpts

OptiSave - Energy Saving System - 1

OpJiSave™ Saving System Optimizing Pump and Fan Speed to Current Conditions and Saving Fuel PROVEN TECHNOLOGY DESMI

Open the catalog to page 1
OptiSave - Energy Saving System - 2

OptiSaveTM is designed to be integrated in new-build vessels as well as in vessels already in operation and can be fully integrated into the vessels’ IAS/AMS/CAMS/ICAMS system. OptiSaveTM is installed onboard +350 vessels around the world, saving more than +8.7 million USD in fuel every year. Customer Says: Andreas Asimakopoulos dep. tech.manager at Minerva Marine: “We selected OptiSaveTM on several projects both as retrofits and as newbuilds on the basis of sound engineering approach compared to competitive products and rigid support through execution stages. Performance of delivered...

Open the catalog to page 2
OptiSave - Energy Saving System - 3

Energy Efficiency Design Index (EEDI) and SEEMP OptiSaveTM helps ship owners and designers to meet the requirement for reduction of C02 stipulated in IMO MEPC 62 rules. OptiSaveTM is designed to be integrated in new-build and The EEDI has been developed for the largest and most retrofit applications and can be fully integrated into the energy intensive segments of the world’s merchant fleet overall Control System. and will cover 72% of emissions from new oil and gas tankers, bulk carriers, general cargo, refrigerated cargo Energy Efficiency Design Index (EEDI) The EEDI for new ships aims at...

Open the catalog to page 3
OptiSave - Energy Saving System - 4

All implemented DESMI OptiSave™ solutions have shown that the relatively inexpensive installations have an average payback time of less than a year The fact that the installed components have an expected lifetime of ten years or more means that you will see a multiple return of your investment. With OptiSave™ we guarantee the most efficient solution, where energy efficiency and fuel savings are key benefits. The systems directly applicable with DESMI OptiSave™ are: • Seawater cooling systems • Steam condenser cooling system • Fresh water cooling systems • Engine room ventilation • Cargo...

Open the catalog to page 4
OptiSave - Energy Saving System - 5

OptiSave™ Master Control pane The OptiSave™ Master Control panel has a modular design offering one common control platform for all the different applications and the possibility of combining more applications into the same system. This ensures the highest possible flexibility during the design and installation phase for both new building vessels and retrofitting of existing vessels. The common control platform is also offering the flexibility to upgrade the OptiSave™ systems to include more application over time. The OptiSave™ Master Control panel is a central control unit, which can be...

Open the catalog to page 5
OptiSave - Energy Saving System - 6

requency ers The OptiSave™ Frequency Converters are designed for marine application with focus on installation in engine room as close to the pump or fan as possible, to lower installation cost and EMI (Electromagnetic interference). OptiSave™ Frequency Converters offer the following special features: • Designed for harsh marine environment • Design temperature up to 50°C without de-rating • Marine coating of circuit boards (3C3) • Internal components are ruggedized • RFI filters suitable IT-net, with co insulations resistance • Two inbuilt DC chocks for reduction of harmonic distortion •...

Open the catalog to page 6
OptiSave - Energy Saving System - 7

OptiSave™ Frequency Converters OptiSave™ Frequency Converters with integrated electro mechanic by-pass Special features: • Same features as OptiSave™ Frequency Converters • Automatic or remote control of by-pass function • Test of function VSD in by-pass mode allowing programming of VSD during by-pass operation The OptiSave™ Frequency Converters with integrated electro mechanic by-pass offer a higher operation safety than the standard OptiSave™ Frequency Converters. With this solution, DESMI offers a full by-pass of the frequency converter. For pumps / fans from 11kW to 90kW, the by-pass...

Open the catalog to page 7
OptiSave - Energy Saving System - 8

Engine Control Room AMSACMSf IACM3 12 OptiSave Touch Panel Engine Room Vessel Monitoring system - (Optional) ■ GTE Data Fuel Consumplion - Usfl dala Unlpi Ctribri Navigation data Engine Room Sea Water Coolmfl System F23DDI-1 Frpsh Wafer OptiSave Frequency FrwUi 'Aalu IrJrl Sfl:l W*IAI hiH< oBjm dump Condon. Engine Room Fresh Water Cooling System f £2001*3 Fr*iH ViMu Pump OptiSave Frequency OpoSiTY* SlirtO r^TCMtvrf wiMT

Open the catalog to page 8
OptiSave - Energy Saving System - 9

g.m£L.PJli&£ SatelliteInternet - Online support - Adjustment of control parameters - Performance data DEgMI Service Cont&f Oposave’1* I rtleffaiC 'nodule 7SU»fc-9l Infcatrwt MiJU* ■ Online support fPLC, HMI and VSD leveh ■ Adjustment of oonlrol parameters - Trouble shoaling Engine Room Ventilation °PtfSai*5 mm E ri>irt FUrOni- ELtono Room. Frt-sh Watai Sharfl ffomnn RUttol I.liii- Enyn« f requency Fr^G Unity DptiSave Frequency Converter w/Bypass rntc\ Jt LW-:^e A'iOti wo/By- pass Er.ir>* RtKMW ENjini Room Fn^i WiWw- C-x-wp

Open the catalog to page 9
OptiSave - Energy Saving System - 10

svs The purpose of the system is to control the seawater cooling pumps to the actual cooling demand at any time by reducing/increasing pump(s)' speed/flow according to the actual needed cooling capacity. OptiSave™ is an intelligent system, which operates the speed/flow of the pumps, taking the following conditions into consideration: • Fresh water temperature (LT) • Sea water outlet temperature (it's kept under scaling temperature for central coolers) • Temperature of electric motors on sea water cooling pumps are monitored • Monitoring of discharge pressure for pumps to ensure water filled...

Open the catalog to page 10
OptiSave - Energy Saving System - 11

Special features for New Building or options: \Z Controlling of priming ejectors in case one of the seawater cooling pumps is used as emergency bilge pump. Dynamic pressure drop monitoring cross coolers and condition controlled flushing Standby function of pumps sj Integrated sequential start Frequency converters on all pumps

Open the catalog to page 11
OptiSave - Energy Saving System - 12

or fresh watecoo ing systems The purpose of the system is to control the LT/FW Cooling water pumps to the actual cooling demand at any time by reducing/increasing pump(s)' speed/flow/pressure according to the actually needed cooling capacity on the fresh water system. OptiSave™ is an intelligent system, which operates the speed/flow/pressure of the pumps, taking the following conditions into consideration: • Fresh water temperature • Fresh water pressure • Main engine load • Main engine lub oil temperature • Shaft bearing temperature • HT/FW temperature • Temperature of electric motors on...

Open the catalog to page 12

All Desmi catalogs and brochures

  1. SPATE PD 75

    2 Pages

  2. Ro-Fence

    2 Pages

  3. Globeboom

    6 Pages

  4. SMART Boom

    2 Pages

  5. CompactClean

    20 Pages

  6. ESL & ESLH

    2 Pages

  7. NSLV & NSLH

    4 Pages

  8. TERMITE

    2 Pages

  9. TERMINATOR

    2 Pages

  10. TARANTULA

    2 Pages

  11. RO-KITE

    2 Pages

  12. RO-BOOM 3200

    2 Pages

  13. RO-BOOM 2200

    2 Pages

  14. RO-BOOM 2000

    2 Pages

  15. RO-BOOM 1800

    2 Pages

  16. RO-BOOM 1500

    2 Pages

  17. RO-BOOM 1300

    2 Pages

  18. RO-BOOM 1100

    2 Pages

  19. RO-BOOM 1000

    2 Pages

  20. RO-BOOM 650

    2 Pages

  21. POLLUTANK

    2 Pages

  22. POLLKITTEN

    2 Pages

  23. POLLCRAFT

    2 Pages

  24. POLLCAT

    2 Pages

  25. POLAR BEAR

    2 Pages

  26. OIL FENCE

    2 Pages

  27. DOP 250 DUAL

    2 Pages

  28. DOP 200 DUAL

    2 Pages

  29. DOP 160

    2 Pages

  30. DESMI BOOM

    2 Pages

  31. CS BOOM

    4 Pages

  32. ALLIGATOR

    2 Pages

  33. A-BOOM

    2 Pages

  34. ROTAN PD

    2 Pages

  35. ROTAN HD

    2 Pages

  36. ROTAN ED

    2 Pages

  37. ROTAN GP

    2 Pages

  38. ROTAN CD

    2 Pages

  39. VAC

    2 Pages

  40. SA

    2 Pages

  41. PVLN

    2 Pages

  42. NSLV/H

    4 Pages

  43. NSL

    4 Pages

  44. NSA

    1 Pages

  45. Modular S

    2 Pages

  46. Modular H

    1 Pages

  47. ESL

    2 Pages

  48. DSL

    2 Pages

  49. DESLUBE

    1 Pages

  50. Cargo Pumps

    8 Pages

  51. OptiPower

    8 Pages

  52. AquaCulture

    12 Pages

  53. Marine

    20 Pages

  54. Ro-Kite

    2 Pages

  55. Oilfence

    2 Pages

  56. Arctic Range

    16 Pages