Catalog excerpts
DESMI Ocean Guard RayClean Ballast Water Treatment System PROVEN TECHNOLOGY DESMI
Open the catalog to page 1RayCleanTM IMO, DNV-GL, Lloyds Register & Class NK Type Approved USCG AMS Accepted RayCleanTM Ballast Water Treatment System is the leading system in the marine industry with unrivalled treatment performance and lowest energy consumption in class. RayCleanTM is IMO, DNV-GL, Lloyds Register and Class NK type approved and tested to meet the latest requirements and guidelines adopted by the International Maritime Organisation (IMO) and the US Coast Guard, from which the system has also earned the Alternate Management System (AMS) acceptance. RayCleanTM can be used in all water salinities and...
Open the catalog to page 2The RayClean™ ballast water treatment system is type approved by IMO and DNV-GL and can treat ballast water at any flowrate from 30 - 3000 m3/h. The system is based purely on mechanical treatment and therefore it does not involve any use of chemicals or active substances. First treatment step is filtration, second step is UV treatment. RayClean™ has no salinity or temperature limitations and has been proven effective in water with UV-T (UV transmission) as low as 0.33, which sets the industry benchmark! Ballasting Operation Mechanical Filtration UV-C Radiation Ballast Water Tanks...
Open the catalog to page 3missio What is UV Transmission? UV-T is a measure of the capability of UV light to penetrate water. When the UV-T is high, close to 100%, the water is very clear and the UV light can penetrate deep into the water. On the other hand, when the UV-T is low (below 50%), the water is very unclear and the UV light can only penetrate a limited distance into the water. In the figure above, two cases with different UV-T are illustrated; one case with a high UV-T of 90%, and another case with just 50% UV-T. Table 1 shows how rapidly the UV intensity decays away from the UV lamp. With a UV-T of 90%,...
Open the catalog to page 4Limitations of Ballast Water Treatment Systems It should be acknowledged that ALL BWTS have limitations. Typically, chemical systems (e.g. electro-chlorination) have limitations related to the salinity of the water to be treated, its temperature or the amount of organic material contained in the water, whereas UV-based BWTS have limitations with regard to the UV transmission of the water to be treated. In other words, all BWTS have special circumstances under which they cannot be expected to treat the water according to the IMO discharge standard. The trick for the ship owner is to select a...
Open the catalog to page 5Simple & Fully Automatic Operation UV Irradiation The UV treatment takes place in units with a flow capacity of 300 m3/h. Each UV unit is equipped with 60 highly efficient low-pressure UV lamps. These lamps are roughly twice as energy-efficient as the widely used medium pressure UV lamps, and as they work at much lower temperature they have superior lifetime and no issues with regard to fouling. Constant online monitoring of the UV intensity inside each unit is used to dim the UV lamps in very clear water (high UV transmission) in order to save energy and to reduce the flow through the unit...
Open the catalog to page 6Filtration RayClean™ has a self-cleaning filter in order to remove the vast majority of organisms larger than 50 micron. During de-ballasting, the filter is used to ensure that organisms, which are small or soft enough to pass the filter on uptake, will be stopped by the filter mesh at discharge, treated and rendered inactive. Furthermore, use of the filter during de-ballasting protects the UV unit from any debris or dirt from the ballast tanks, such as rust flakes or pieces of ballast tank coating. The RayClean™ filter system has a unique and patent pending way of recirculating the filter...
Open the catalog to page 7Our systems can be delivered as loose components, skid-mounted or containerized. Loose components means that the system will be assembled onboard the vessel, and this is often necessary for retrofit projects or installation of large systems. We often deliver skid-mounted systems as they are the optimum solution for newbuildings and small to medium size systems. Complete containerized systems are a third option, which is used for retrofit on container vessels or on the deck of tankers with no space available elsewhere. A fourth option is semi-skid mounted systems, which means that filter and...
Open the catalog to page 8The System can be Delivered in a Special EX Version for Installation in Hazardous Areas The RayClean-EXTM ATEX certification enables the system to be installed directly in Zone 1 hazardous area, Ex II 2G EX pxb [ia/ib] IIC T4 Gb. Our ATEX certified version of RayClean™ enables installation in all typical hazardous areas found on board normal commercial tankers and gas carriers. The general protection principle used is purge and pressurization, which means that all potential ignition sources are covered by enclosures that are purged and pressurized with air in order to maintain an...
Open the catalog to page 9Say “Yes” TM to RayClean because... All Water Salinities RayCleanTM is proven effective in all water salinities, including fresh water, muddy water & cold water. This gives your ship the flexibility of travelling around the world, making sure de-ballasting is allowed in every harbour. Low Energy Consumption With RayCleanTM you will have very low operating expenses. Due to the use of highly efficient lowpressure UV lamps, the energy consumption is the lowest in class and the lifetime of these lamps is a staggering 12,000 hours. Safety Safety is a top priority and many steps have been taken...
Open the catalog to page 10The low power consumption is achieved by use of highly energy-efficient low-pressure UV lamps combined with lamp dimming in clear water (high UV-T) and flow reduction in very challenging and unclear water (low UV-T). By monitoring the UV intensity inside each unit the lamps can be dimmed when the intensity is higher than the critical level, and the flow can be reduced when the intensity is lower than the critical level. This results in a constantly applied UV dose independently of the UV-T of the water to be treated, and enables the RayClean™ system to treat water with UV-T anywhere from...
Open the catalog to page 11All Desmi catalogs and brochures
-
SPATE PD 75
2 Pages
-
Ro-Fence
2 Pages
-
Globeboom
6 Pages
-
SMART Boom
2 Pages
-
CompactClean
20 Pages
-
DESMI FineFog™
8 Pages
-
ESL & ESLH
2 Pages
-
MARINE & OFFSHORE
20 Pages
-
NSLV & NSLH
4 Pages
-
TERMITE
2 Pages
-
TERMINATOR
2 Pages
-
TARANTULA
2 Pages
-
RO-BOOM Speed Sweep
2 Pages
-
RO-BOOM BEACH 800
2 Pages
-
RO-BOOM 3200
2 Pages
-
RO-BOOM 2200
2 Pages
-
RO-BOOM 2000
2 Pages
-
RO-BOOM 1800
2 Pages
-
RO-BOOM 1500
2 Pages
-
RO-BOOM 1300
2 Pages
-
RO-BOOM 1100
2 Pages
-
RO-BOOM 1000
2 Pages
-
RO-BOOM 650
2 Pages
-
POLLUTANK
2 Pages
-
POLLKITTEN
2 Pages
-
POLLCRAFT
2 Pages
-
POLLCAT
2 Pages
-
POLAR BEAR
2 Pages
-
OIL FENCE
2 Pages
-
HELIX SKIMMER
2 Pages
-
GLOBEBOOM'ED extra duty
2 Pages
-
GIANT OCTOPUS
2 Pages
-
DOP 250 DUAL
2 Pages
-
DOP 200 DUAL
2 Pages
-
DOP 160
2 Pages
-
DESMI BOOM
2 Pages
-
DBD 40 SKIMMER
2 Pages
-
DBD 20 SKIMMER
2 Pages
-
DBD 16 SKIMMER
2 Pages
-
DBD 13-4 SKIMMER
2 Pages
-
DBD 5 SKIMMER
2 Pages
-
DBD 2 SKIMMER
2 Pages
-
CS BOOM
4 Pages
-
ALLIGATOR
2 Pages
-
A-BOOM
2 Pages
-
ROTAN PD
2 Pages
-
ROTAN HD
2 Pages
-
ROTAN ED
2 Pages
-
ROTAN GP
2 Pages
-
ROTAN CD
2 Pages
-
How to identify a ROTAN pump
1 Pages
-
DESMI Priming Pump B114
2 Pages
-
DESMI Priming Ejector
2 Pages
-
Spare Parts Kits
2 Pages
-
Vertical Pumps DP
8 Pages
-
VAC
2 Pages
-
SA
2 Pages
-
PVLN
2 Pages
-
NSLV/H
4 Pages
-
NSL- Stainless Steal
4 Pages
-
NSL
4 Pages
-
NSA
1 Pages
-
Modular S
2 Pages
-
Modular H
1 Pages
-
ESL
2 Pages
-
DSL
2 Pages
-
DESLUBE
1 Pages
-
Fine-Fog (fire-fighting)
8 Pages
-
Cargo Pumps
8 Pages
-
Pumps For Free
2 Pages
-
OptiSave - Energy Saving System
20 Pages
-
OptiPower
8 Pages
-
Commissioning
4 Pages
-
AquaCulture
12 Pages
-
Automation Solutions
12 Pages
-
DESMI Scrubber Pumps
8 Pages
-
DESMI AfterSales
12 Pages
-
DESMI 48 - Fast Track
8 Pages
-
Engine Room Pumps
16 Pages
-
Marine & Offshore Pump Solutions
28 Pages
-
Marine
20 Pages
-
DESMI KaziCat
4 Pages
-
DESMI Landing Craft range
8 Pages
-
DESMI Grafter
4 Pages
-
Lease Hire Equipment
2 Pages
-
Industrial Skimmers
2 Pages
-
Workboats - New Generation
12 Pages
-
Oilfence
2 Pages
-
Offshore Vessel Solutions
2 Pages
-
Arctic Range
16 Pages
-
Speed-Sweep system
2 Pages
-
Oil Spill Response Equipment
40 Pages
-
DESMI Article Collection
56 Pages
-
Company Profile
24 Pages