NEW Salinometer for Freshwater Generators and Boilers SL8005 Daniamant design and manufacture all of our products in line with the relevant worldwide approvals, ­ echnical t specifications, current legislation and International directives. Our mission is to achieve World class performance through partnerships with our suppliers, customers and employees, providing products and services that enhance the safety and security of our customers. Daniamant products cover eight key areas: • Lifejacket Lights • Liferaft Lights • Lifebuoy Lights • Intrinsically Safe Lights • Special Lights • Bridge Navigational Watch Alarm System (BNWAS) • Salinometers • Agency for a range of world-renowned safety product brands (supplied to the Danish market) Further Information For further information on our products, please see our website: www.daniamant.com Panel mounting model The salinometer measures and supervises the salinity (salt content) by conductivity measurement in fresh water. The measured value is displayed as ppm and by comparing the measured value to a user defined alarm setpoint value, relay outputs are available to indicate if salinity is above or below the alarm setpoint value. In areas where fresh water generation or purification is taking place and level of salinity in the fresh water must be monitored as well as in areas where a set level of salinity is requested in a process. Salinometers are used in: Freshwater Generators, Boilers, Reversed Osmosis Fresh Water Systems (RO) and other systems where salinity has to be supervised. Mains Supply 85 - 265 V AC, 50/60 Hz, 10 VA typ. - 15 VA max. Mains supply must be protected against overcurrent by an external 250 mA slow-blow fuse. Measuring Salinity Range Measuring salinity range: 0 - 200 ppm, displayed as “000” to “199” and “HI” if value exceeds 200 ppm. Alarm Function User defined alarm setpoint value (0 - 199 ppm) is set using “+” and “-“ buttons. When measured value exceeds alarm setpoint, change-over relay contacts A and B are activated. Alarm relay B may be enabled/disabled from the front by pressing a button. Wall mounting model Electrode unit

Open the catalog to page 1
Salinometer_SL8005_Brochure - 2

Daniamant Electronics A/S Industrivej 24C 3550 Slangerup Denmark Alarm function: User defined alarm setpoint value (0 – 199 ppm) is set using stepped “+” and “-“ buttons. When measured value exceeds alarm setpoint, change-over relay contacts 1 and 2 are activated. Alarm relay 2 may be enabled/disabled from the front by pressing a button. Function: The salinometer measures and supervises the salinity (salt content) by conductivity measurement in fresh water. The measured value is displayed as ppm, and, by comparing the measured value to a user defined alarm setpoint value, relay outputs are...

Open the catalog to page 2

All Daniamant catalogs and brochures

  1. DanEI-300

    2 Pages

  2. FLS 2D

    2 Pages

Archived catalogs