POWER PLANT & CO - GENERATION SYSTEM
20Pages

{{requestButtons}}

Catalog excerpts

POWER PLANT & CO - GENERATION SYSTEM - 1

DAIHATSU DIESEL MFG. CO.,LTD

Open the catalog to page 1
POWER PLANT & CO - GENERATION SYSTEM - 2

THE DAIHATSU CO-GENERATION SYSTEM, which generates electricity and heat energy at the same time will, CONTRIBUTE The Daihatsu Co-Generation system is an environment-protective type electricity and heat generating system that effectively utilize an independent generating plant which is powered by our diesel engine or gas engine, and its waste heat. •The Daihatsu Diesel engine has a wide output range up to 5,500kw per engine. •As the prime mover, either our diesel engine or gas engine can be used according DAIHATSU CO-GENERATION SYSTEM

Open the catalog to page 2
POWER PLANT & CO - GENERATION SYSTEM - 3

TO ENERGY SAVING AS WELL AS ENVIRONMENTAL PROTECTION Important features of the Daihatsu Co-Generation System •Each of the prime mover employed (diesel engine or gas engine) advances the concept of environmental protection. •Each of the engine has been designed with utmost priority on thermal efficiency, and less fuel consumption. •Long-term achievements in the field of general-purpose of marine

Open the catalog to page 3
POWER PLANT & CO - GENERATION SYSTEM - 4

Specifications for The Daihatsu Co-Generation System Specifications of diesel engines •Engine output is based on an engine chamber temperature of 5~40°C. an altitude of less 300m, humidity of 8596, and cooling water temperature of 32°C. •NOx content in the exhaust gas is less than 950ppm (1 3%02). •The maximum temperature of the exhaust gas for heat recovery is 200°C for steam and •Steam volume for saturation is at 0.78MPa (8 kgf/cm2G). •Supplied water temperature for heat recovery is 20°C. However, it is 60°C at the boiler inlet. •Jacket water temperature at the engine outlet is 80t. •As...

Open the catalog to page 4
POWER PLANT & CO - GENERATION SYSTEM - 5

Specifications for The Daihatsu Co-Generation System •Engine output is based on engine chamber temperature of 5—4013, an altitude of less 300m, humidity of 85% and cooling water temperature of 32°C. •The maximum temperature of the exhaust gas for heat recovery is 20010 for steam and 1 5010 for warm water. •Steam volume for saturation is at 0.78MPa (8 kgf/cm2G). •Supplied water temperature for heat recovery is 2010. However, it is 6010 at the boiler inlet. •Jacket water temperature at the engine outlet is 90°C. •As for the specifications of the radiator, please consult us. •Since the outputs...

Open the catalog to page 5
POWER PLANT & CO - GENERATION SYSTEM - 6

Equipment Layout for The Daihatsu Co-Generation System (Examples) Example in case of 1 engine

Open the catalog to page 6
POWER PLANT & CO - GENERATION SYSTEM - 7

Equipment Layout for The Daihatsu Co-Generation System (Examples) Example in case of 3 engines

Open the catalog to page 7
POWER PLANT & CO - GENERATION SYSTEM - 8

Dimensions and Weight of Generators and Engines for The Daihatsu Co-Generating System The number in parentheses indicates vibration-insulated mounting. * Engine base plate only.

Open the catalog to page 8
POWER PLANT & CO - GENERATION SYSTEM - 9

Three-Dimension Sectional Drawing of Engines for The Daihatsu CO-Generation System

Open the catalog to page 9
POWER PLANT & CO - GENERATION SYSTEM - 10

Flow Chart of Piping for The Daihatsu Co-Generation System Example of Steam Recovery Warm water Heat exchanger Warm water Diesel engine feed pump storage tank

Open the catalog to page 10
POWER PLANT & CO - GENERATION SYSTEM - 11

Flow Chart of Piping for The Daihatsu Co-Generation System Example of Warm Water Recovery Water supply ■ Warm water sump tank transfer pump storage tank

Open the catalog to page 11
POWER PLANT & CO - GENERATION SYSTEM - 12

Sales Achievements The Daihatsu Co-Generation System has been exhibiting its performance

Open the catalog to page 12
POWER PLANT & CO - GENERATION SYSTEM - 13

in various ways such as the stable supply of electrical power, pursuit of efficiency, and energy saving.

Open the catalog to page 13
POWER PLANT & CO - GENERATION SYSTEM - 14

Sales Achievements The Daihatsu Co-Generation System has been exhibiting its performance

Open the catalog to page 14
POWER PLANT & CO - GENERATION SYSTEM - 15

in various ways such as the stable supply of electrical power, pursuit of efficiency, and energy saving.

Open the catalog to page 15
POWER PLANT & CO - GENERATION SYSTEM - 16

Sales Achievements The Daihatsu Co-Generation System has been exhibiting its performance

Open the catalog to page 16
POWER PLANT & CO - GENERATION SYSTEM - 17

in various ways such as the stable supply of electrical power, pursuit of efficiency, and energy saving. NGK SPARK PLUG CO.,LTD

Open the catalog to page 17
POWER PLANT & CO - GENERATION SYSTEM - 18

Sales Achievements The Daihatsu Co-Generation System has been exhibiting its performanct

Open the catalog to page 18
POWER PLANT & CO - GENERATION SYSTEM - 19

in various ways such as the stable supply of electrical power, pursuit of efficiency, and energy saving.

Open the catalog to page 19
POWER PLANT & CO - GENERATION SYSTEM - 20

Daihatsu Diesel's engines, gas engines, reduction gears, gas turbines and other products are manu- factured under excellent quality assurance systems The industry-leading quality assurance systems of Daihatsu Diesel's Headquarters and Moriyama Works, covering every aspect of de- sign, development, manufacture and off-site maintenance —the first manufacturer in this field in Japan to be accredited for this as- pect — are certified as satisfying the requirements of ISO 9001. As a result all engines, gas turbines and marine-use equipment of Dai- hatsu Diesel are manufactured under quality...

Open the catalog to page 20

All Daihatsu Diesel Pro catalogs and brochures

  1. CMAXS LC-A

    2 Pages

  2. SCR SYSTEM

    4 Pages

  3. 6DE-18

    4 Pages

  4. 6DE-23

    4 Pages