CYGNUS 4+

CYGNUS 4+

CYGNUS 4+

Product catalog summary
Purpose and Application: The Cygnus 4+ General Purpose thickness gauge is a versatile, durable device designed for measuring wall thickness in high-temperature, in-service environments without requiring shutdowns. It is ideal for use in ship surveys, pipes, tubes, and storage tanks, particularly in the oil and gas sector.
Key Features: The device offers multiple measurement modes, including Multiple-Echo, Echo-Echo, and Single-Echo, to accommodate various conditions such as coatings and corrosion. It features a sunlight-readable display, data logging capabilities, and is housed in a water and dust-tight IP67 casing. It is also shock and impact-proof, meeting US MIL STD 810G standards.
Measurement Capabilities: The Cygnus 4+ can measure thicknesses from 0.8mm to 250mm, depending on the probe and material. It supports high-temperature measurements up to 300°C and offers a resolution of 0.1mm or 0.05mm in Multiple-Echo mode.
Data Management: The device includes basic data logging with an auto-log feature, storing up to 5000 measurements and A-scans per record. Data can be managed using CygLink software, which allows for remote logging, viewing of A-scan graphs, and report generation.
Safety and Compliance: The Cygnus 4+ is safe for use in explosive atmospheres and complies with various standards, including EN 15317, CE, UKCA, and RoHS. It is designed to withstand harsh environmental conditions, including high and low temperatures, humidity, and immersion.
Warranty and Support: The device comes with a 3-year warranty on the gauge and a 6-month warranty on the probe. Support is available through Cygnus offices in the UK, USA, UAE, and Singapore.
See more

Catalog excerpts

CYGNUS 4+-1

RELIABLE ULTRASONIC MEASUREMENT CYGNUS 4+ GENERAL PURPOSE ULTRASONIC THICKNESS GAUGE The Cygnus 4+ General Purpose thickness gauge is a light, tough multi-mode thickness gauge. It features a sunlight readable display with Live A-scan, intuitive menu and sequential data logging for easy reporting and analysis. Used with Cygnus High Temperature Probe, the Cygnus 4+ can measure remaining wall thickness of high-temperature, in-service assets without shutdown or isolation. IDEAL FOR USE IN OIL AND HIGH STORAGE GAS TEMPERATURE TANKS PIPES/ TUBES SHIP SURVEYS ...plant maintenance, civil engineering, ship inspections, oil and gas facilities. High-temperature, in-service thickness surveys across refining, oil and gas, energy and process sectors. WWW.CYGNUS-INSTRUMENTS.COM

 Open the catalog to page 1
CYGNUS 4+-2

CYGNUS 4+ GENERAL PURPOSE CYGNUS 4+ GENERAL PURPOSE KEY FEATURES Multiple-Echo mode for accurate, through-coat measurements as specified by Classification Societies Echo-Echo and Single-Echo modes for heavily corroded metals with a thin or no coating Deep Coat function ignores coatings up to 20mm thick Manual and automatic gain control Min/max measurement limit functions with visual and vibrate alert Large front sunlight readable LCD display with Live A-scan Water and dust tight IP67 housing Shock and impact proof to US MIL STD 810G Safe operation in explosive atmospheres: Class 1, Division 2,...

 Open the catalog to page 2
CYGNUS 4+-3

Cygnus High Temp Probe T5B-MAUH (Twin Crystal) For use on hot surfaces up to 300oC. Measures remaining wall thickness from 1.5mm to 250mm - depending on temperature and material. No cooling period required - reducing inspection time and facilitating more effective measurement. Option to use a standard cable or a more robust, braided cable. BASIC DATA LOGGING • • Linear based data logging Auto-log feature Eight user-defined comments to attach to any measurement point Saves measurements and A-scans Records stored on SD card CygLink software used to transfer and manage data Standard Cable Braided...

 Open the catalog to page 3
CYGNUS 4+-4

CYGNUS 4+ GENERAL PURPOSE SPECIFICATION Feature Measuring Modes Multiple-Echo using 3 echoes to ignore coatings up to 20mm thick Echo-Echo using 2 echoes to ignore coatings up to 1mm thick Single-Echo using 1 echo Velocities from 1,000 - 9,000 m/s (0.0390 - 0.3543 in/us) ±0.05 mm (±0.002”) - in Multiple-Echo measurement mode, when calibrated and measuring the same material as calibrated on. ±0.1 mm (±0.004”) or 0.1% of thickness measurement whichever is the greatest - in Single-Echo & Echo-Echo measurement modes, when calibrated and measuring the same material as calibrated on. Multiple-Echo...