Catalog excerpts
Switch mode BATTERY CHARGER User Manual and Guide to professional charging of starter and deep cycle batteries.
Open the catalog to page 1Congratulations on purchasing your new CTEK professional switch mode battery charger. This charger is part of a range of professional battery chargers from CTEK SWEDEN AB. It represents the latest technology in battery charging with charging and analysis in eight steps with temperature compensation Read this User Manual and follow the instructions carefully before using your new charger. • The charger is designed to charge lead acid batteries. Do not use the charger for any other purpose • Wear protective goggles and turn your face away when connecting or disconnecting the battery1 • During...
Open the catalog to page 2IMPORTANT INFORMATION FOR MULTI XT 14000 and XT 14000 Please note that the battery pack in the 24 V system in most cases consists of more than one battery. They are linked up to the 24 V system, but the individual batteries generally have a lower voltage. Therefore it is important for the charger to be connected correctly BATTERY TYPES AND SETTINGS The XS 25000 and XT 14000 are programmed according to "PROGRAM DESCRIPTION" with fixed settings. MULTI XS 2500 and MULTI XT 14000 can easily be set for different types of batteries or conditions. The following recommendations should, however,...
Open the catalog to page 3Recond (Lamp 5) (only on MULTI XS 25000 and MULTI XT 14000) This mode Is used to recover deeply discharged flooded batteries. Recondition of deep discharged batteries. The voltage ncreases with reduced current for a limited time period. The higher voltage starts some gassing and mixing of the acid, which Is beneficial for both battery capacity and expected life. Note that the battery could emit explosive gas during Recond. Recond Is performed between Analysis and Maintenance Lamp Description 0 Fault mode, the charging Is discontinued. For fault causes, 5 Supply (Only on MULTI XS 25000 and...
Open the catalog to page 4TEMPERATURE COMPENSATION MULTI XS 25000, XS 25000, MULTI XT 14000 and XT 14000 have a sensor cable placed together with the battery cables. The units will automatically adjust the charging voltage If the temperature deviates from +25 C. A high temperature lowers the voltage and freezing conditions Is handled by higher voltage The temperature Is best measured on or very close to the battery. Therefore always place the sensor as close to the battery as possible when charging. The sensor cable could be prolonged or cut to length with the same functionality. A short-circuited or disconnected...
Open the catalog to page 5battery retains battery life
Open the catalog to page 7The charger is maintenance-free. The charger must not be opened; doing so will invalidate the warranty. If the power cable is damaged it must be replaced by CTEK or its authorized representative. The charger casing can be cleaned using a damp cloth and mild cleaning agent. Remove the plug from the power socket before cleaning LIMITED WARRANTY CTEK SWEDEN AB, Rostugnsv. 3, SE-776 70 VIKMANSHYTTAN, SWEDEN issues this limited warranty to the original pur- chaser of this product. This limited warranty is not transferable. CTEK SWEDEN AB warrants this unit for two years from the date of purchase...
Open the catalog to page 8All Ctek catalogs and brochures
-
MXS 10EC
2 Pages
-
LITHIUM XS
2 Pages
-
CTX BATTERY SENSE
2 Pages
-
XS 7000
2 Pages
-
XT 14000
2 Pages
-
MXS 5.0 TEST AND CHARGE
2 Pages
-
MXS 5.0 POLAR
2 Pages
-
XS 0.8_EN
2 Pages
-
M 45
2 Pages
-
MXS 5.0_EN
2 Pages
-
MXS 7.0_EN
2 Pages
-
MXS 10_EN
2 Pages
-
MXS 25_EN
2 Pages
-
M 100_EN
2 Pages
-
M 200_EN
2 Pages
-
M 300_EN
2 Pages
-
D250S DUAL_EN
2 Pages
-
SMARTPASS
2 Pages
-
MXTS 70
2 Pages
-
D250TS_EN
2 Pages
Archived catalogs
-
ONYX
2 Pages
-
CTEK ZAFIR 90
3 Pages
-
MULTI XS 3600
2 Pages
-
CTEK XC 800
2 Pages
-
MULTI XS 7000
2 Pages
-
CTEK XS 800
2 Pages