Technical Specifications:
The document outlines the specifications for high-pressure sodium and metal halide floodlights, ranging from 150-400 watts. It highlights the AEx nR, Ex nR restricted breathing rating for hazardous locations, and the NEMA 7x6 butterfly beam pattern for efficient light distribution. The construction is NEMA Type 4X and IP66 rated, suitable for marine and wet locations, with a temperature suitability of 40˚C to 65˚C and low ambient capability to -40˚C. The design includes a hinged door frame for easy relamping and a yoke mount for flexible installation.

Housing and Materials:
The housing is made of heavy-duty copper-free aluminum with a Corro-Free™ epoxy powder coat finish. It includes stainless steel hardware and a tempered glass lens that is heat and impact resistant.

Electrical Components:
The floodlights come with a multi-tap ballast for various voltages and optional configurations. The lamp holder is a mogul base, and the luminaires are supplied without lamps.

Approvals and Standards:
The floodlights are approved for Class I Division 2 and Class II Division 1 hazardous locations, among others, and meet several UL and cUL standards.

Applications:
Suitable for hazardous locations, onshore drilling, pipeline storage, corrosive environments, and security lighting.

Ordering and Spare Parts:
The document provides part numbers for ordering ballasts and lamps, along with mounting options and special configurations.
See more

Catalog excerpts

Pauluhn? HazFlood DFL/al Floodlights-1

• Hazardous locations • Onshore drilling and exploration • Pipeline compressor pipeline " Corrosive environments Fagade security lighting • 150 - 400w high pressure sodium or 175-400w metal halide. • AEx nR, Ex nR restricted breathing rating is standard—restricted breathing offers cooler T-numbers for increased hazardous locations • NEMA 7x6 butterfly beam floodlight pattern—wide, uniform and far reaching to provide excellent efficiency and more light where you need • NEMA Type 4X and IP66 heavy-duty, die-cast copper-free aluminum construction is designed for use indoors and outdoors in marine and wet locations with stainless steel external hardware suitable for saltwater and corrosive applications. • 40°C, 55°C and 65°C ambient suitability—addresses high ambient common at industrial facilities. • Low ambient capability to -40°C—perfect for colder climates. • Hinged door frame assembly—has captive cover screws for ease of • Yoke mount design—standard construction provides the greatest mounting flexibility, can be mounted vertically (wall), horizontally (rooftop or floor) or any angle in between. • 3-axis resonance withstand and UL844 vibration compliant—can stand • Precision formed aluminum reflector—superior beam control, • High light output with a low cost of operation—cost-effectiveness in a high-wattage floodlight. • Slipfitter Adapter for Pole mounting and Wall Mounting bracket is • Class I Division 2 Groups A, B.C&D • NEMA Type 4X • Class II Division 1 Groups F and G (250W • Wet Locations • UL/cUL 844 - Hazardous Locations requirements for luminaires for installation TECHNICAL SPECIFICATIONS HOUSING/LENS FRAME Heavy duty copper-free aluminum die-cast, finished with Corro-Free™ epoxy powder coat. WIND RATING MOUNTING BRACKETS Yoke mount aluminum, finished with Corro-Free™ epoxy powder coat. Please see SPECIAL OPTIONS for additional selections. Stainless steel. Precision formed aluminum. Tempered glass, heat and impact resistant. LAMP HOLDER Mogul base, porcelain. LAMP TYPES High Pressure Sodium, Metal Halide Probe Start* and Metal Halide Pulse Start. Luminaires supplied without lamps. Crouse-Hinds PAULUHN

 Open the catalog to page 1
Pauluhn? HazFlood DFL/al Floodlights-2

ORDERING REFERENCES PART NUMBER LAMP TYPE ANSI LAMP SPECIAL OPTIONS -230 - Replace "220" (only) with "230" *Lamp is not included unless option "L" is selected. SPARE PARTS

 Open the catalog to page 2

All Cooper Crouse-Hinds Pauluhn catalogs and brochures

  1. nLLK

    4  Pages

  2. NFL_broch

    4  Pages

  3. EVLS_Hazard

    20  Pages

  4. FZD

    4  Pages

  5. EVI Series

    12  Pages

  6. ELPS_brochure

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.