ELPS_brochure
1 /4Pages

ELPS_brochure

ELPS_brochure
1 /4Pages

Catalog excerpts

ELPS_brochure-1

Emergency Lighting System For Hazardous Areas COOPER Crouse-Hinds

 Open the catalog to page 1
ELPS_brochure-2

ELPS LIGHT-PAK TM Emergency Lighting System For Hazardous Areas † Class I, Groups B, C, D Class II, Groups E, F, G Class III, NEMA 3R, 4X, 12 * Suitable for wet locations *NEMA 4X pending with new ECD 4X breather and drain. Aimable and lockable—no set screws. Wrench tight unions allow positive xture positioning. A NEW FAMILY OF EMERGENCY LIGHTING The Light-Pak emergency lighting system from Cooper Crouse-Hinds® is the only hazardous area system with lighting xtures designed specically for emergency lighting. The aimable, lockable, light-directing, tungsten halogen xtures enable you to put emergency...

 Open the catalog to page 2
ELPS_brochure-3

FEATURES BENEFITS • Explosionproof emergency light providing 90 minutes of continuous light • Self calibrating—self calibrates after initial charge • Automatic condence test every month • Automatic battery capacity check every 6 months • Visual status indication of the Light-Pak is readily available through LED indication • Between lamp head and power supply there is a factory installed seal • The only Division 1 emergency light with adjustable lamp heads that cast light down long hallways or corridors • Meets all National Fire Protection Agency requirements for the Life Safety Code and combined...

 Open the catalog to page 3
ELPS_brochure-4

ELPS LIGHT-PAK TM Emergency Lighting System For Hazardous Areas DIMENSIONS (INCHES) SUGGESTED SPECIFICATION 33.00 EXS/EXD 35.63 EXD GB General The emergency lighting system shall be explosionproof and dust-ignitionproof, UL Listed (UL844) for Class I, Groups B, C, D; Class II, Groups E, F, G; and Class III. Power supply also shall be UL Listed as “Emergency Lighting and Power Equipment” (UL924). System shall be rated 120, 220, 240, 277 VAC; with a 12 VDC output supply to the lamps. Unit shall be furnished with a push-to-test switch and AC monitor pilot light as standard; and optional integral...

 Open the catalog to page 4

All Cooper Crouse-Hinds Pauluhn catalogs and brochures

  1. nLLK

    4  Pages

  2. NFL_broch

    4  Pages

  3. EVLS_Hazard

    20  Pages

  4. FZD

    4  Pages

  5. EVI Series

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.