Product catalog summary
Overview: The document provides technical specifications and details for the NMEA Data Output Unit NETcourse by CASSENS & PLATH GmbH. It outlines data protocols, technical data, approvals, and order numbers related to the product.
Data Protocol: The unit supports IEC61162-1, -2, or NMEA 183A protocols. It outputs data in the format $HCHDG,x.x ,,,,*hh and $HCHDM,x.x,m*hh, where x.x represents the heading in degrees with one decimal place. The transmission rate is up to 1 or 10 per second at 4800 baud, 8 data bits, no parity, and 1 stop bit (4800B;8N1). For IEC1162-2, the rate is 30 per second at 38400 baud (38400B;8N1).
Technical Data: The unit features a digital two-line display for menu interaction, data transmission rates of 1, 10, and 30 per second, and digital data output according to IEC 61162-1 (NMEA 183A), RS422, and RS485. It includes a point-to-point transmission error correction routine, a dimmable display, and automatic checks against azimuth sensor drop and magnetic interference. The accuracy is better than +/- 0.5°, and it has a power failure alarm for main/emergency supply voltage. The main and emergency power supply is 24 VDC with automatic change-over.
Approvals: The unit is MED type approved for combination with REFLECTA magnetic compass binnacles of German Lloyd according to various IMO and ISO standards, including IMO A.382(X), IMO A.694(17), MSC.191(79), ISO449(1997), and others. It complies with directives 2009/26/EC, 2010/68/EC, and 2011/75/EC.
Order Numbers: The complete NETcourse system with azimuth sensor, control unit, and cables is available under order number 198010. A mounting/distance adapter for the azimuth sensor is available under order number 14207, and a USB data cable for heading data output is available under order number 198011.
Systematic Scheme: The document includes a schematic overview of the system, detailing components such as the main/emergency supply, cables, junction box, magnetic compass, binnacle, azimuth sensor, and data output connections. Notes indicate which components are included in the delivery range.
See more

Catalog excerpts

NETcourse-1

NMEA Data Output Unit NMEA Kursdatengeber Systematic Scheme System-Ubersicht Magnetic Compass, 1* Magnet-Kompass, 1* Sonde CP/102B,2* Sonde CP/102B, 2* Detector cable, 1.5 m,5 way, screened, w. connector, 2* Sondenkabel, 1.5 m, 5 adrig, geschirmt, mit Stecker, 2* Cable, 15 m (max. 40 m), 5 way, screened, connector at the monitor, 2* Kabel, 15 m (max. 40 m), 5 adrig, geschirmt, Stecker am Monitor, 2* Main-/emergency Supply, 24 VDC, 4 m, 2 way, screened, with connector, 2* Haupt-/Not Spannung, 24 VDC, 4 m, 2 adrig, geschirmt, mit Stecker, 2* Data Output, 4 m, 2 way, screened, with connector, 2* Datenausgang, 4 m, 2 adrig, geschirmt, mit Stecker, 2* Notes: 1* not included in range of delivery 2* included in range of delivery 1* nicht im Lieferumfang entahlten 2* im Lieferumfang enthalten Technical Data •Digital two line display for menu interaction •Data transmission rate 1, 10 & 30/sec •Digital data output according to IEC 61162-1 (NMEA 183A), RS422 & RS485 (ref. to info last page) •Different output signal specifications •Point to point transmission error correction routine •Display dimmer •Automatically check of azimuth sensor against drop and interfering magnetic fields •Monitor with built-in frame •Accuracy better than +/- 0.5° •Power failure alarm for main/ emergency supply voltage •Main and emergency power supply 24 VDC with automatic change-over •With REFLECTA Kompassen MED certified • Immune against electromagnetic interferences acc. to IEC 60945 Technische Daten •Digitate zwei Zeilen Anzeige fur Menu Auswahl •Datenubertragungsrate 1, 10, 30/Sek •Digitaler Datenausgang nach IEC 61162-1 (NMEA 183A), RS422 & RS485 (Siehe Info letzte Seite) •Unterschiedliche Ausgangs-Signal Spezifikationen •Kurs zu Kurs Ubertragungsfehler Korrektur-Routine •Dimmbare Anzeige •Automatischer Check gegen Abfallen des Azimut Sensors & magnetische Storfelder •Einbaumontage •Genauigkeit besser als +/- 0,5° •Alarm bei Versagen von Haupt-/Not-Spannung •Haupt- und Notspannung 24 VDC mit automatischer Umschaltung •Mit REFLECTA Kompassen MED zugelassen •EMV fest gemab IEC 60945 Alterations and Errors reserved/Anderungen und Fehler vorbehalten

 Open the catalog to page 1
NETcourse-2

NMEA Data Output Unit NMEA Kursdatengeber Data Protocol Daten Protokoll IEC61162-1, -2 oder NMEA 183A $HCHDG,x.x „„*hh<CR><LF> $HCHDM,x.x,m*hh<CR><LF> with x.x heading in °, one decimal mit x.x Kurs in °, eine Dezimalstelle without leading zero ohne fuhrende Nullen with hh check sum mit hh Prufsumme RS422 Transmission rate: max. 1 or 10/sec 4800 baud, 8 databits, no parity 1 stopp bit (4800B;8N1) If IEC1162-2: (38400B;8N1) 30/sec, 38400 Baud Different protocols on request &Rs485: Ubertragungsrate 1 oder 10/sek 4800 Baud, 8 Datenbits, keine Paritat, 1 Stoppbit (4800B;8N1) Fur IEC 1162-2: (38400B;8N1)...

 Open the catalog to page 2

All Cassens & Plath GmbH catalogs and brochures

  1. REFLECTA/1/EC

    4  Pages

  2. SESTREL SR4

    2  Pages

  3. Pelorus

    2  Pages

  4. Signals

    2  Pages

  5. DELTA

    2  Pages

  6. BETA

    2  Pages

  7. CROSScourseV

    2  Pages

  8. SENSOcourse

    2  Pages

  9. CAMcourse

    4  Pages

  10. TRUEcourse

    4  Pages

  11. NEMAcourse

    2  Pages

  12. EPR-El-1

    2  Pages

  13. IOTA1

    2  Pages

  14. Walker 2050

    2  Pages

  15. REFLECTA/5

    2  Pages

  16. REFLECTA/4

    2  Pages

  17. REFLECTA/3

    4  Pages

  18. REFLECTA/2

    4  Pages

  19. REFLECTA/1

    4  Pages

  20. Clinometer

    1  Page

  21. Chronometers

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.