V-Series Contura® IV, V & VII
15Pages

{{requestButtons}}

Catalog excerpts

V-Series Contura® IV, V & VII - 1

Contura® IV, V & VII Sealed Rocker Switches P ROD UC T WE BP A GE request sample, configure part, watch video Contura® IP66/68 Snap-In Mounted Switches The V-Series switches are well known for their cutting edge design, high quality, maximum performance and unmatched reliability. These snap-in rocker switches offer countless options for ratings, circuits, colors, illuminations and symbols. These single or double pole switches feature removable actuators in a choice of actuator styles and colors, which may be purchased and stocked separately. An optional plug-in terminal connector enables pre-wiring of wire harness. Typical Applications ∙ On/Off-Highway ∙ Marine ∙ Any Application Requiring Seali

Open the catalog to page 1
V-Series Contura® IV, V & VII - 2

Design Features INTERCHANGEABLE ACTUATORS Panel redesign is a snap with our wide range of rocker styles. Achieve maximum design variety with minimum inventory. Simply swap rockers to create an entirely new look for your panel. OPTIONAL PANEL SEAL Helps prevent water/ dust ingress behind panel. DUAL SEAL PROTECTION Seals out water, dust, debris, and sealed to IP66/68 for above-panel components MULTIPLE LIGHTING OPTIONS In addition to Incandescent lamps, our LED illumination is offered in a wide array of light intensities, colors, as well as dual level, tri-color, and flashing options. CLEAN...

Open the catalog to page 2
V-Series Contura® IV, V & VII - 3

Actuator Options & Accessories Contura II & III Contura X helps prevent inadvertent The Contura II & III actuators are polycarbonate and are offered with a hard nylon overlay or a “soft-touch” elastomer overlay. These models incorporate aesthetic designs on the top and bottom of the rocker featuring two rows of raised “bumps” actuation of the rocker, as well as preventing debris from being trapped under the actuator. This curved rocker style is available with a variety of lenses and legends. on the Contura II and three “indented” lines on the Contura III. a Shape” actuator works with the...

Open the catalog to page 3
V-Series Contura® IV, V & VII - 4

Tech Specs Electrical Contact Rating IP66/68, for above-panel components of actual switch only. Mixed Flowing Gas (MFG) Class III 3 year accelerated exposure per ASTM B-827, B-845 Silver and gold contacts Dielectric Strength Operating Temp Insulation Resistance Initial Contact Resistance Up to 100,000 cycles, circuit and load dependent Per Mil-Std 202F, Method 204D Test Condition A 0.06 DA or 10G’s 10-500 Hz. Tested with VCH connector. Test criteria - No loss of circuit during test, pre and post test contact esistance. Silver alloy, silver tin-oxide, fine silver Brass or copper/silver plate...

Open the catalog to page 4
V-Series Contura® IV, V & VII - 5

Ordering Scheme Sample Part Number Selection *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 6,7. LAMP (SAME CODING FOR BOTH SELECTIONS) 4. TERMINATION / BASE STYLE 8 term 10 Term 1 2 A B J K 3 4 C D 5 6 E F Termination .250 TAB (QC) no barriers .250 TAB (QC) with barriers .250 TAB (QC) no barriers Solder Lug no barriers Solder Lug Wire Leads no barriers Wire Leads Selection 6: above terminals 1 & 4; Selection 7: above...

Open the catalog to page 5
V-Series Contura® IV, V & VII - 6

Ordering Scheme Sample Part Number Selection Terminal Connections as viewed ( ) - momentary from bottom of switch: SP - single pole: terminals 1, 2 & 3. 8 terminal 10 terminal DP - double pole: terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10- - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONE OFF 2 B (ON) NONE OFF 3 C ON NONE (OFF) 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 &...

Open the catalog to page 6
V-Series Contura® IV, V & VII - 7

Ordering Scheme Sample Part Number Selection Terminal Connections as viewed ( ) - momentary from bottom of switch: SP - single pole: terminals 1, 2 & 3. 8 terminal 10 terminal DP - double pole: terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 erminals 7, 8, 9 & 10 for lamp circuit only. T 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10- - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONE OFF 4 D ON NONE ON 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) 9 N OFF NONE ON 8. FLUSH BRACKET COLOR, PANEL SEAL No Seal One Seal 9. HARD SURFACE ACTUATOR Black Gray Red...

Open the catalog to page 7
V-Series Contura® IV, V & VII - 8

Ordering Scheme Sample Part Number Selection Terminal Connections as viewed ( ) - momentary from bottom of switch: SP - single pole: terminals 1, 2 & 3. 8 terminal terminal 10 DP - double pole: terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10- - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONE OFF 2 B (ON) NONE OFF 3 C ON NONE (OFF) 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 &...

Open the catalog to page 8
V-Series Contura® IV, V & VII - 9

Dimensional Specs inches [millimeters] SHOWN WITH SHOWN WITH BAR BAR LENS LENS 8 TERMINAL 8 TERMINAL BASEBASE W/O BARRIERS W/BARRIERS 8 TERMINAL BASE 10 TERMINAL BASE W/BARRIERS W/O BARRIERS OTTOM VIEW TERMINAL RRANGEMENT ERMINAL BASE SWITCH SHOWN WITH VCH CONNECTOR 8 SWITCH SHOWN WITH TERMINAL VC1 CONNECTOR 10 TERMINAL 8 TERMINAL BASE BASE 10 TERMINAL W/O BARRIERS W/O BARRIERS 10 TERMINAL BASE W/BARRIER AND 10 TERMINAL BASE LAMP TERMINAL W/O BARRIERS 10 TERMINAL BASE W/BARRIER AND 8 TERMINAL BASE LAMP TERMINAL W/O BARRIERS 8 TERMINAL BASE BASE 8 TERMINAL W/BARRIERS W/O BARRIERS SHOWN...

Open the catalog to page 9
V-Series Contura® IV, V & VII - 10

Circuit Diagrams: CIRCUIT CODE CIRCUIT DIAGRAM CIRCUIT CODE CIRCUIT DIAGRAM CIRCUIT CODE DEFINITION DESIGNATES TERMINALS AND CONTACTS DESIGNATES MAINTAINED CIRCUITS DESIGNATES OTHER POSITION DESIGNATES MOMENTARY CIRCUITS DESIGNATES TWO POSITION CONNECTION DESIGNATES EXTERNAL JUMPER PROVIDED BY CUSTOMER

Open the catalog to page 10

All Carling Technoligies catalogs and brochures

  1. BD1-Series

    5 Pages

  2. CPV-Series

    6 Pages

  3. PC-Series

    10 Pages

  4. PB-Series

    10 Pages

  5. CTB-Series

    3 Pages

  6. CMB-Series

    5 Pages

  7. CLB-Series

    5 Pages

  8. V-Series

    8 Pages

  9. CSW-Series

    7 Pages

  10. 4M-Series

    6 Pages

  11. LW-Series

    5 Pages

  12. LMR-Series

    3 Pages

  13. CLTM12-Series

    10 Pages

  14. LD-Series

    4 Pages

  15. CKJ-Series

    7 Pages

  16. CKP-Series

    10 Pages

  17. CM-Series

    15 Pages

  18. BD-Series

    8 Pages

  19. VP-Series

    6 Pages

  20. CLTM12-Series

    10 Pages

  21. W-SERIES

    10 Pages

  22. HR-Series

    10 Pages