PC-Series Equipment Leakage Circuit Interrupters P ROD UC T W E BP A GE request sample, configure part The PC-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines ground fault protection with the familiar overcurrent tripping characteristics of a normal circuit breaker to protect against low-level faults when installed near water. Based on the principles of hydraulic-magnetic design, the breaker also operates reliably when exposed to extreme heat or cold. This breaker series is available in one to three pole configurations and rated from .10-50 amps, 120VAC, 120/240VAC with max IC of 5,000 amps Typical Applications ∙ Marine ∙ AC Main Ground Fault Protection for a boat’s entire AC electrical system
Open the catalog to page 1Tech Specs Current Ratings Voltage Ratings Leakage Current Trip Time Operating Frequency Reverse Polarity A reversed Line / Load connection to the circuit breaker shall not cause damage to the device Grounded Neutral When neutral is grounded on load side of circuit 50 operations @ 600% of rated current on Breakers Switched Neutral 2nd Pole on 120V and 3rd Pole on 120/240V, Optional Manual Test To be performed at least every month by pressing the test button on the ELCI to verify the device’s ability to respond and trip when subjected to simulated leakage. Current imbalance is sufficient to...
Open the catalog to page 2Tech Specs Agency Approvals UL 1053 Ground Fault Sensing and Relaying Equipment Ignition Protection Table A: UL Recognized as an Equipment Leakage Circuit Interruptor - 120 and 120/240V UL Recognized Configurations as an Equipment Leakage Circuit Interruptor Circuit Configuration Series Series Ignition Protection Short Voltage Current Circuit Rating Frequency Phase (Amps) Capacity (Hertz) (Amps) Ground Fault Trip Level (Milliamps) 1 or 2 Poles. One pole of a two pole unit must be Neutral Construction Notes 2 or 3 Poles. One pole of a three pole unit must be Neutral 1 or 2 Poles. One pole of...
Open the catalog to page 3Ordering Scheme Sample Part Number Selection 120 VAC single phase, 1 pole 120/240 VAC single phase, 2 pole 120/240 VAC single phase with switched neutral, 3 pole 120 VAC single phase with switched neutral, 2 pole 240 VAC single phase, 2 pole 3. POLES Series Trip (Current) 4. CIRCUIT Handle A 1 per breaker pole B 1 per unit Two Color Curved Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single Color Curved Rocker J Vertical legend K Horizontal legend Two Color Curved Visi-Rocker Push-to-Reset N...
Open the catalog to page 4Dimensional Specs inches [millimeters] INDICATE OFF / SINGLE COLOR ROCKER ACTUATOR PCC 120/240 VAC VERSION W/ NEUTRAL BREAK TERMINAL LOCATIONS PCD 120 VAC VERSION W/NEUTRAL BREAK HANDLE / INDICATE ON ROCKER ACTUATOR
Open the catalog to page 5Dimensional Specs inches [millimeters] URCE TRAL LOAD HOT 2 OR 230V NEUTRAL LOAD HOT 1 HANDLE ACTUATOR ROCKER ACTUATOR PANEL CUTOUT DETAIL ROCKER ACTUATOR TOLERANCES ±.005 [.12] PANEL CUTOUT DETAIL NEUTRAL PIGTAIL (CIRCUIT CODE A+B ONLY) Notes: For additional circuit breaker dimensions, reference the C-Series Breakers in the Carling Circuit Protection catalog
Open the catalog to page 6Ordering Scheme Sample Part Number Selection 5. MOUNTING SCREWS / PLATE MATERIAL Circuit Breaker Assembly 3. ACTUATOR TYPE 1 Handle, one per pole 2 Handle, one per multipole unit A Rocker 4. POLES PER UNIT - INCLUDING ELECTRONIC MODULE 3 Three 5 Five RUBBER SEAL MOUNTING PLATE 6-32 Thread Phillips Head M-3 Thread Phillips Head 6-32 Thread Slotted Head M-3 Thread Slotted Head 6-32 Thread Phillips Head with Stainless Steel Plate M-3 Thread Phillips Head with Stainless Steel Plate 6-32 Thread Slotted Head with Stainless Steel Plate M-3 Thread Slotted Head with Stainless Steel Plate Notes: 1...
Open the catalog to page 7Dimensional Specs Handle Actuator HANDLE, 1 PER MULTIPOLE UNIT Rocker Actuator
Open the catalog to page 8Time Delay Instantaneous Ultra Short No Trip No Trip No Trip No Trip No Trip Time Delay Values Percent of Rated Current 200% Notes: Other time delay values available, consult factory. Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve. Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in...
Open the catalog to page 9Authorized Sales Representatives and Distributors Click on a region of the map below to find your local representatives and distributors or visit www.carlingtech.com/findarep. MIDDLE EAST ASIA-PACIFIC OCEANIA SOUTH AMERICA About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With six ISO9001 and IATF16949 registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales,...
Open the catalog to page 10All Carling Technoligies catalogs and brochures
-
BD1-Series
5 Pages
-
CPV-Series
6 Pages
-
PB-Series
10 Pages
-
CTB-Series
3 Pages
-
CMB-Series
5 Pages
-
CLB-Series
5 Pages
-
C1005B-Series
3 Pages
-
V-Series
8 Pages
-
CSW-Series
7 Pages
-
4M-Series
6 Pages
-
LW-Series
5 Pages
-
LMR-Series
3 Pages
-
LD-Series
4 Pages
-
CKJ-Series
7 Pages
-
CKP-Series
10 Pages
-
CM-Series
15 Pages
-
BD-Series
8 Pages
-
VP-Series
6 Pages
-
CLTM12-Series
10 Pages
-
AV/AVH-Series
6 Pages
-
W-SERIES
10 Pages
-
V-Series Contura® IV, V & VII
15 Pages
-
V-Series Contura® II & III
13 Pages
-
HR-Series
10 Pages