AHD-WAOP Watch Alarm Panel (BNWAS) Watch duty times adjustable on device Automatic illumination dimming Mushroom Button Integrated Emergency Call The AHD-WAOP watch alarm panel (BNWAS) meets the requirements settled in IEC62616-1. The watch alarm panel ensures the watch standby of the bridge crew. The watch duty times can be changed after entering a user code. The selected time runs down and has to be acknowledged before it runs off. If there is no acknowledgement, predefined alarms are raised successively: First the display and the mushroom button of the device start flashing, followed by the internal buzzer and Alarm Relay “Stage 1”, followed by the internal buzzer and Alarm Relay ”Stage 2”, followed by Alarm Relay “Stage 3”. For a better recognition the display of the unit is by turns illuminated red and green, the mushroom button flashes red. For the watch alarm panel times up to 12 minutes can be selected. The AHD-WAOP watch alarm panel is equipped with a mushroom button. If the mushroom button is pushed for 5 seconds, an emergency alarm is triggered. Pushing the mushroom button again will deactivate the alarm. All system configurations as for example change of time, change of passwords and many more are performed with the system keys and are displayed on the screen. Up to four external acknowledgement buttons can be directly connected, allowing an easy acknowledgement of alarms from different points on the bridge (freely extendable by parallel connection). If the used buttons are accordingly equipped, even a simultaneous flashing of internal and external buttons is
Open the catalog to page 1Watch Alarm Panel Technical information Operation voltage Maximum load Operating temperature Storage temperature Protection Class 70 mm x 130 mm x 80 mm 4 inputs for external buttons External Start input External Stop input External buzzer (250VAC/0,5A) Alarm 2 (250VAC/0,5A) General Alarm (250VAC/0,5A) Fault output (250VAC/0,5A) RS 485 (2 terminals for communication, e.g. with VDR ) Approvals / Classifiaction Societies Böning Automationstechnologie GmbH & Co. KG • Am Steenöver 4 • D-27777 Ganderkesee • E-Mail:[email protected] • www.boening.com PaB-1004 Rev.: Feb 02, 2012 The manufacturer accepts...
Open the catalog to page 28 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
8 Pages
2 Pages
2 Pages
2 Pages
4 Pages
3 Pages
4 Pages
2 Pages
6 Pages
2 Pages
5 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
2 Pages
4 Pages
2 Pages
4 Pages
8 Pages
5 Pages
4 Pages
2 Pages
12 Pages
12 Pages
12 Pages
10 Pages
2 Pages
88 Pages
2 Pages
2 Pages
8 Pages
12 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
2 Pages
4 Pages
4 Pages