AHD-GAP F
2Pages

{{requestButtons}}

Catalog excerpts

AHD-GAP F - 1

• Operation of signal horn from wheelhouse in case of an emergency situation • Preprogrammed signals "Abandon Ship," "General Alarm," "Fire Alarm" • Key for manual signal sequences • Integrated priority circuit The control panel AHD-GAP F is designed for the control of acoustic and optical signals in emergency situations. In addition to the manual activation of the horn, the common mandatory signals "Abandon Ship," "General Alarm," and "Fire Alarm" are hardcoded and can be activated in selectable intervals. The first button press activates the preprogrammed signal sequence, while a second button press deactivates the previously activated signal sequence. The integrated priority circuit ensures that the signal "Abandon ship" has priority over the signals "General Alarm," and "Fire Alarm". Upon activation of the manual signal generator, currently running signal sequences are paused for 20 seconds and then resumed. It is possible to connect external devices with which a general alarm or a fire alarm can be triggered or the currently emitted signal sequence can be interrupted, for example for loudspeaker announcements. Additionally, the general alarm sequence can be triggered by an externally connected AHD-WAOP (Watch alarm unit BNWAS). The unit is protected against unintended activation with a keylock. Manual signals can be generated even in case of a malfunction of the device. AHD-GAP F is designed for installation in bridge consoles and other control stations. The front panel's entire surface is coated with a waterproof, UV resistant and durable plastic film. All controls are illuminated glare-free for safe operation at night time. The signal LEDs' brightness is automatically adjusted to the ambient light by a built-in photo sensor. The pluggable Phonix terminal strip makes simple and fast connection as well as exchange of the device possible. ii Bonmc Automationstechnologie

Open the catalog to page 1
AHD-GAP F - 2

Technical Information Boning Automationstechnologie GmbH & Co. KG • Am Steenover 4 • D-27777 Ganderkesee • E-Mail: info@boening.com • www.boening.com PaB 1116 V5 Rev Dec. 6th, 2017 • Texts and Illustrations not binding. Changes may be made due to technical improvements.

Open the catalog to page 2

All Böning Automationstechnologie GmbH & Co. KG catalogs and brochures

  1. AHD-S 201

    4 Pages

  2. AHD 882

    4 Pages

  3. AHD-SAS 15

    4 Pages

  4. AHD-UIC

    2 Pages

  5. AHD-DPS02

    4 Pages

  6. AHD-POS 10

    4 Pages

  7. AHD-WOP

    2 Pages

  8. AHD 1119 G

    2 Pages

  9. AHD 1219 F

    2 Pages

  10. AHD 1119 F

    2 Pages

  11. AHD-WNL

    4 Pages

  12. AHD 406

    3 Pages

  13. AHD 414A

    4 Pages

  14. AHD-DPU 9

    2 Pages

  15. AHD-RB6

    6 Pages

  16. AHD-UCC

    2 Pages

  17. 8794

    5 Pages

  18. AHD-EST

    2 Pages

  19. AHD-SLPV2

    4 Pages

  20. AHD-WAOP

    2 Pages

  21. AHD 1124 G

    2 Pages

  22. AHD 414

    4 Pages

  23. AHD-DRM R

    2 Pages

  24. AHD-SLP V2

    4 Pages

  25. AHD- S 201

    4 Pages

  26. AHD-VSC CF

    12 Pages

  27. AHD-VSC C

    12 Pages

  28. AHD 1110 F

    2 Pages

  29. AHD 1310 F

    2 Pages

  30. AHD 1224 G

    2 Pages

  31. HM-Series

    8 Pages

  32. AHD-VC 711

    12 Pages

  33. AHD 880 E

    4 Pages

  34. AHD 880 TC

    2 Pages

  35. AHD 880 G

    2 Pages

  36. AHD 514 A

    4 Pages

  37. AHD-EOP

    2 Pages

  38. AHD-S 201

    4 Pages

  39. AHD_882

    4 Pages

Archived catalogs

  1. AHD-S 230

    4 Pages

  2. AHD 200

    4 Pages