Catalog excerpts
• Operation of signal horn from wheelhouse in case of an emergency situation • Preprogrammed signals "Abandon Ship," "General Alarm," "Fire Alarm" • Key for manual signal sequences • Integrated priority circuit The control panel AHD-GAP F is designed for the control of acoustic and optical signals in emergency situations. In addition to the manual activation of the horn, the common mandatory signals "Abandon Ship," "General Alarm," and "Fire Alarm" are hardcoded and can be activated in selectable intervals. The first button press activates the preprogrammed signal sequence, while a second button press deactivates the previously activated signal sequence. The integrated priority circuit ensures that the signal "Abandon ship" has priority over the signals "General Alarm," and "Fire Alarm". Upon activation of the manual signal generator, currently running signal sequences are paused for 20 seconds and then resumed. It is possible to connect external devices with which a general alarm or a fire alarm can be triggered or the currently emitted signal sequence can be interrupted, for example for loudspeaker announcements. Additionally, the general alarm sequence can be triggered by an externally connected AHD-WAOP (Watch alarm unit BNWAS). The unit is protected against unintended activation with a keylock. Manual signals can be generated even in case of a malfunction of the device. AHD-GAP F is designed for installation in bridge consoles and other control stations. The front panel's entire surface is coated with a waterproof, UV resistant and durable plastic film. All controls are illuminated glare-free for safe operation at night time. The signal LEDs' brightness is automatically adjusted to the ambient light by a built-in photo sensor. The pluggable Phonix terminal strip makes simple and fast connection as well as exchange of the device possible. ii Bonmc Automationstechnologie
Open the catalog to page 1Technical Information Boning Automationstechnologie GmbH & Co. KG • Am Steenover 4 • D-27777 Ganderkesee • E-Mail: info@boening.com • www.boening.com PaB 1116 V5 Rev Dec. 6th, 2017 • Texts and Illustrations not binding. Changes may be made due to technical improvements.
Open the catalog to page 2All Böning Automationstechnologie GmbH & Co. KG catalogs and brochures
-
AHD-DPS02 System
8 Pages
-
AHD-S 201
4 Pages
-
AHD 882
4 Pages
-
AHD-SAS 15
4 Pages
-
AHD-UIC
2 Pages
-
AHD-DPS02
4 Pages
-
AHD-POS 10
4 Pages
-
AHD-WOP
2 Pages
-
2018 AHD 504 / AHD 514
8 Pages
-
AHD 1119 G
2 Pages
-
AHD 1219 F
2 Pages
-
AHD 1119 F
2 Pages
-
AHD-WNL
4 Pages
-
AHD 406
3 Pages
-
AHD 414A
4 Pages
-
AHD-DPU 9
2 Pages
-
AHD-RB6
6 Pages
-
AHD-UCC
2 Pages
-
8794
5 Pages
-
AHD-EOP/ AHD-DEOP
2 Pages
-
AHD-EST
2 Pages
-
AHD-SLPV2
4 Pages
-
AHD-WAOP
2 Pages
-
AHD 1124 G
2 Pages
-
AHD 414
4 Pages
-
AHD-DRM R
2 Pages
-
AHD-SLP V2
4 Pages
-
AHD- S 201
4 Pages
-
Cabin Control System
8 Pages
-
Selector Switch A250
5 Pages
-
AHD 1119 G / AHD 1115 G
4 Pages
-
AHD 1219 G / AHD 1215 G
2 Pages
-
AHD-VSC CF
12 Pages
-
AHD-VSC C
12 Pages
-
AHD - VCS Video Control System
12 Pages
-
2014 AHD 504 / AHD 514
10 Pages
-
AHD 1110 F
2 Pages
-
AHD 1310 F
2 Pages
-
Catalog Ship Automation
88 Pages
-
AHD 1224 G
2 Pages
-
HM-Series
8 Pages
-
AHD-VC 711
12 Pages
-
AHD 880 E
4 Pages
-
AHD 880 TC
2 Pages
-
AHD 880 G
2 Pages
-
AHD 1119 F / AHD 1115 F
4 Pages
-
AHD 1219 F / AHD 1215 F
2 Pages
-
AHD 514 A
4 Pages
-
AHD-EOP
2 Pages
-
AHD-S 201
4 Pages
-
AHD_882
4 Pages
-
Superyacht_Business_10-2009
1 Pages