AHD 880 E 8,8” Touch screen Engine Display Applicable for engine systems of reputable engine manufacturers Operation via touch screen Transflective display with high luminous intensity (250 cd/m2) Automatically adjusted display brightness The AHD 880 E colour display was developed for operation as an engine display for indication and alarm presentation of relevant operating data of connected engine systems. The compact design of the unit with a degree of protection IP 66 at the front side allows operation of the display in wheelhouse control consoles as well as in fly bridge consoles. The data communication is performed via CAN-Bus, where engine data may be recorded and presented from most varied data protocols like e.g. SAE J1939, Modbus, NMEA 0183, NMEA 2000 etc.. Therefore, the AHD 880 E display is excellently convenient in applications with engine systems of reputable engine manufacturers (MAN, MTU, Caterpillar, Volvo-Penta, Cummins etc…). The engine operating data and display configuration is presented on multiple instrument, alarm, measuring point and configuration pages by means of graphical resp. tabular visualization. The applied instruments are available with black or in some applications also with white scale. The 8,8" colour display with transflective screen provides best clearness of display of data information even in case of strong solar radiation. The scrolling through screen pages and the execution of all further display functions is performed by touch screen operation. Additionally, a remote control can be connected to the remote input. In addition, a GPS-receiver can be connected to the RS232 interface for presentation of ship speed over ground. Expansions and retrofits with AHD 880 E can be carried out efficiently inclusive integration of additional analog measuring values by means of data acquisition modules.
Open the catalog to page 1Screen pages (Examples) Instrument pages: The engine display AHD 880 E provides several instrument pages, presenting the most important engine data by means of analog instruments or bar graphs. The actual measuring value is highlighted by an additional clearly readable digital display. Further analog measuring point data are presented by digital displays as well. Limit ranges for warning and alarm are marked within scales of instruments by appropriate colour code. Also dynamically altered limit ranges, e.g. in dependence of engine speed can be displayed. Existing alarm messages in the...
Open the catalog to page 2Deutscti Meliic(*C,bar, liters) I I > 1(K I Alarm pages: The alarm page of engine display AHD 880 E is call up by operating corresponding function key on instrument page. All existing alarms and warnings are registered with LED-indication in clearly structured tabular form and in chronological order of appearance, combined with actual measuring value. Emergency monitoring page: For dual engine applications, the AHD 880 E is provided with an emergency monitoring page. In case of failure on second engine display, the engine data of both engines are presented in tabular form. Configuration...
Open the catalog to page 3Technical Data Dimension W x H x D: Viewing angle: 3 x CAN Bus 1 x RS232 1 x Video In (Composite Video, PAL 50 Hz) Operating temperature: Storage temperature: 1 x binary (Opto coupler) IP 66 (front side) IP 22 (rear side) Panel/console desk installation Approvals: Classification societies Germanischer Lloyd Lloyd´s Register of Shipping Req. distance to compass: Steering magn. compass: 70 cm Standard magn. compass: 40 cm Power supply: Power consumption: Visible display area: Luminous intensity: Display resolution: Colour depth: Böning Automationstechnologie GmbH & Co. KG • Am Steenöver 4 •...
Open the catalog to page 4All Böning Automationstechnologie GmbH & Co. KG catalogs and brochures
-
AHD-DPS02 System
8 Pages
-
AHD-S 201
4 Pages
-
AHD 882
4 Pages
-
AHD-SAS 15
4 Pages
-
AHD-UIC
2 Pages
-
AHD-DPS02
4 Pages
-
AHD-POS 10
4 Pages
-
AHD-WOP
2 Pages
-
2018 AHD 504 / AHD 514
8 Pages
-
AHD 1119 G
2 Pages
-
AHD 1219 F
2 Pages
-
AHD 1119 F
2 Pages
-
AHD-WNL
4 Pages
-
AHD 406
3 Pages
-
AHD 414A
4 Pages
-
AHD-DPU 9
2 Pages
-
AHD-RB6
6 Pages
-
AHD-UCC
2 Pages
-
8794
5 Pages
-
AHD-EOP/ AHD-DEOP
2 Pages
-
AHD-EST
2 Pages
-
AHD-SLPV2
4 Pages
-
AHD-WAOP
2 Pages
-
AHD 1124 G
2 Pages
-
AHD 414
4 Pages
-
AHD-DRM R
2 Pages
-
AHD-SLP V2
4 Pages
-
AHD-GAP F
2 Pages
-
AHD- S 201
4 Pages
-
Cabin Control System
8 Pages
-
Selector Switch A250
5 Pages
-
AHD 1119 G / AHD 1115 G
4 Pages
-
AHD 1219 G / AHD 1215 G
2 Pages
-
AHD-VSC CF
12 Pages
-
AHD-VSC C
12 Pages
-
AHD - VCS Video Control System
12 Pages
-
2014 AHD 504 / AHD 514
10 Pages
-
AHD 1110 F
2 Pages
-
AHD 1310 F
2 Pages
-
Catalog Ship Automation
88 Pages
-
AHD 1224 G
2 Pages
-
HM-Series
8 Pages
-
AHD-VC 711
12 Pages
-
AHD 880 TC
2 Pages
-
AHD 880 G
2 Pages
-
AHD 1119 F / AHD 1115 F
4 Pages
-
AHD 1219 F / AHD 1215 F
2 Pages
-
AHD 514 A
4 Pages
-
AHD-EOP
2 Pages
-
AHD-S 201
4 Pages
-
AHD_882
4 Pages
-
Superyacht_Business_10-2009
1 Pages