Monitoring System for Diesel Engines Compact system for Start, Stop ind. Emergency Stop and Monitoring of Propulsion Diesel Engines Brilliant colour display with VGA resolution Automatically adjusted display brightness The monitoring system for Diesel engines is designed as a compact system for start, stop and monitoring (ind. emergency stop release) of propulsion Diesel engines on board of ships. All required in- and outputs and corresponding moni- toring and control functions for applications with propulsion engines are integrated in the components When designing the components, a high value was set on easy connection and maintenance and service. Connection is available as far as possible directly at terminal lists of system components and reduces by that significantly the demand of material and installa- tion with resulting reduction of costs. The configuration of the complete system is created by means of an included PC-Software, which allows setting of required parameter with different authori- zation levels. Components of the Complete System: AHD 514-A Start/Stop-System with combined Alarm Compact microprocessor-controlled unit with profile module housing for console, panel or switchbox in- stallation on profile rails TS32/TS35. AHD 514-A controls start and stop of the Diesel en- gine and assumes control of all required monitoring functions incl. automatic stop at overspeed. Integrated alarm and event log memory for logging of up to 10000 alarms and events. Recall of data via
Open the catalog to page 1AHD 514-S Safety System with combined Emergency Stop System: Compact microprocessor-controlled unit with profile module housing for console, panel or switchbox installation on profile rails TS32/TS35. All safety functions, predetermined by classification societies for monitoring systems for Diesel engines Two separated 24 V DC power supplies for emergen- cy stop circuit and safety system. Emergency stop function independently from safety function. Separate processing of emergency stop inputs and stop criteria. An initiated emergency stop is routed directly to the emergency stop output. On break-...
Open the catalog to page 2Lockable on profile rail TS 32/35 Installation height 77 + rail
Open the catalog to page 3Operating temperature: Storage temperature: Power supply: Current consumption: Analog inputs configurable 1 x Speed input, galv. isolated 2 x binary, wire-breakage monitored 8 x binary ( Control inputs) 2 x binary (Safety monitoring) 8 x Relay 6 A, potential free (Control outputs, Starter relays) monitored , short-circuit proof for engine stop agnostics/ log read out, Firmware- 1 x serial Input (Optocoupler) 2 x serial Output (Optocoupler) Profile module housing, installation Operating temperature: Storage temperature: Power supply: Current consumption: 18 ... 32 V DC Emerg. Stop System 2 x binary,...
Open the catalog to page 48 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
8 Pages
2 Pages
2 Pages
2 Pages
4 Pages
3 Pages
4 Pages
2 Pages
6 Pages
2 Pages
5 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
4 Pages
2 Pages
4 Pages
8 Pages
5 Pages
4 Pages
2 Pages
12 Pages
12 Pages
12 Pages
10 Pages
2 Pages
88 Pages
2 Pages
2 Pages
8 Pages
12 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
4 Pages
4 Pages