AHD 414A Alarm / Safety System
4Pages

{{requestButtons}}

Catalog excerpts

AHD 414A Alarm / Safety System - 1

AtamVlroacft»«urK] BuQStriNruter Odrucfc/nang* Tagauari* i N'/*4Ui min Tagoatan* 2 Nmmu mn Wmm«! *f'i M**cr»n*M*um Rutf* atvlapd UtWtttt LecttNarik Nwaau mti AJOgastorrperatur max Orucklaga* Tamparaiuf max TrebOICOaflaurtank Niveau max M**cttr*nrawnwia« Nr.'oau max Mo«or r Ofllnofc OUruckmimoal Mow Kitfii»auonornp»iaiu' *u>f4> Oovf&vh/Mhl UCfp LutoUttomperefijr WttfflUAQ AbgaBlerrpotalur Warr.jng KraltatolHvcMge Wamung Drahtbrucft AnsieUkreia > SonsorteCuna _ MOTOR AUTO STOPP • Approved as Alarm or Safety System • Compact system for monitoring sensors, switches, and contacts • Panel installation unit using proven technology • Flexible and adjustable to individual requirements • 10 free inputs • Time-delayed alerting • Horn relay and 3 freely programmable group relays • Serial interface • Inputs for external acknowledgement • Input for alarm release • Override-Function (safety system) • Wire break monitoring of inputs and group relay K1 (stop relay for safety sys tem • Designed for maritime use according to classification society guidelines (e.g. GL, LR, ABS, BV)

Open the catalog to page 1
AHD 414A Alarm / Safety System - 2

General Information Group Relay The AHD 414A Alarm and Safety System is a compact unit with 10 free binary inputs for alarm and status notifications. The AHD 414A features 3 group relays, which can be assigned to every alarm. It is also possible to assign several group relays to a single alarm. The group relays can be programmed as initial value or new value indicators. In addition, they can be programmed as normal closed (NC) or normal open (NO). If the device is used as a safety system, the relay K1 always works as a normal open contact and initial value indicator. Alarms and Status...

Open the catalog to page 2
AHD 414A Alarm / Safety System - 3

Connections Diagram Böning Automationstechnologie GmbH & Co. KG • Am Steenöver 4 • D-27777 Ganderkesee • E-Mail:info@boening.com • www.boening.com HoA-1041 V5 Rev. Jan 7, 2015 • Texts and Illustrations not binding. Changes may be made due to technical impr

Open the catalog to page 3
AHD 414A Alarm / Safety System - 4

Dimensions, W x H x D Panel Cutout Weight Installation Type, Housing Boning Automationstechnologie GmbH & Co. KG • Am Steenover 4 • D-27777 Ganderkesee • E-Mail:info@boening.com • www.boening.com HoA-1041 V5 Rev. Jan 7, 201 5 • Texts and Illustrations not binding. Changes may be made due to technical improvements

Open the catalog to page 4

All Böning Automationstechnologie GmbH & Co. KG catalogs and brochures

  1. AHD-S 201

    4 Pages

  2. AHD 882

    4 Pages

  3. AHD-SAS 15

    4 Pages

  4. AHD-UIC

    2 Pages

  5. AHD-DPS02

    4 Pages

  6. AHD-POS 10

    4 Pages

  7. AHD-WOP

    2 Pages

  8. AHD 1119 G

    2 Pages

  9. AHD 1219 F

    2 Pages

  10. AHD 1119 F

    2 Pages

  11. AHD-WNL

    4 Pages

  12. AHD 406

    3 Pages

  13. AHD 414A

    4 Pages

  14. AHD-DPU 9

    2 Pages

  15. AHD-RB6

    6 Pages

  16. AHD-UCC

    2 Pages

  17. 8794

    5 Pages

  18. AHD-EST

    2 Pages

  19. AHD-SLPV2

    4 Pages

  20. AHD-WAOP

    2 Pages

  21. AHD 1124 G

    2 Pages

  22. AHD 414

    4 Pages

  23. AHD-DRM R

    2 Pages

  24. AHD-SLP V2

    4 Pages

  25. AHD-GAP F

    2 Pages

  26. AHD- S 201

    4 Pages

  27. AHD-VSC CF

    12 Pages

  28. AHD-VSC C

    12 Pages

  29. AHD 1110 F

    2 Pages

  30. AHD 1310 F

    2 Pages

  31. AHD 1224 G

    2 Pages

  32. HM-Series

    8 Pages

  33. AHD-VC 711

    12 Pages

  34. AHD 880 E

    4 Pages

  35. AHD 880 TC

    2 Pages

  36. AHD 880 G

    2 Pages

  37. AHD 514 A

    4 Pages

  38. AHD-EOP

    2 Pages

  39. AHD-S 201

    4 Pages

  40. AHD_882

    4 Pages

Archived catalogs

  1. AHD-S 230

    4 Pages

  2. AHD 200

    4 Pages