video corpo

The SECCANT Range: Regenerative dryer for air and gas
8Pages

{{requestButtons}}

Catalog excerpts

The SECCANT Range: Regenerative dryer for air and gas - 1

the SECCANT RangE Regenerative dryer for air and gas 1500 – 3500 l/min 90 – 420 bar EASY INTEGRATION B-CONTROL COMPRESSOR CONTROL OPTIONAL FILTER MONITORING GAS-TIGHT HELIUM CONSTRUCTION Drying air and gases economically. At high pressures and high throughput. This is the strong point of the SECCANT regenerative dryer from Bauer. For dehumidifying and purifying air, nitrogen and rare gases, the SECCANT regenerative dryers offer a tailor-made system solution for every application. For solutions requiring absolute continuous operation, where the processes do not permit any interruption, can also be used in combination with a bypass filter system from BAUER. By means of an external control room, online control and online monitoring of SECCANT and the compressor unit can be implemented.

Open the catalog to page 1
The SECCANT Range: Regenerative dryer for air and gas - 2

BAUER KOMPRESSOREN Low-maintenance operation for more economic efficiency The regenerative dryer SECCANT from BAUER offers efficiency and safety when purifying air and gases. All downstream consumers, pipes and valves are highly effectively protected from corrosion, icing and soiling. The SECCANT regenerative dryer offers a gas purity which complies with the requirements of sensor technology, medicine and ultrapure gas applications. Optional: With the help of an additional filter housing containing activated carbon, breathing air quality according to DIN EN 120211 can be obtained. Owing to...

Open the catalog to page 2
The SECCANT Range: Regenerative dryer for air and gas - 3

fully automatically controls all processes such as cycle times, pressure compensation, change-over and condensate draining. The large, eight line LCD display with free language choice* provides information on all important parameters. * 13 languages at present 2 The condensate separator removes condensed water and oil drops from the incoming flow of process gas/air. with activated carbon removes oil vapour and hydrocarbons from the process gas/air stream. The treated air corresponds in quality to pure air in accordance with DIN EN 120211. (Standard scope of supply of the SECCANT 3A / 4A...

Open the catalog to page 3
The SECCANT Range: Regenerative dryer for air and gas - 4

BAUER KOMPRESSOREN B-CONTROL, the centre of communication Continuous control maintains operational security B-CONTROL fully automatically monitors and controls all SECCANT‘S internal functions like - Operating hours - Operating reports - SECURUS (optional) - Pressure dew point (optional) At the same time SECCANT‘S B-CONTROL communicates with the compressor‘s respective unit control: At start and stop the compressor unit sends SECCANT an On/Off signal. SECCANT permanently monitors itself during operation and sends the compressor a release signal. If a release signal is not received, the...

Open the catalog to page 4
The SECCANT Range: Regenerative dryer for air and gas - 5

1 On/Off signal from the compressor unit to SECCANT 2 Stand by report from SECCANT to the compressor unit Status report from SECCANT to the B-CONTROL II of the compressor unit 3 Forwarding of operating reports by B-MESSENGER via email or SMS 4 Compressur units with B-CONTROL II Compressur units without B-CONTROL

Open the catalog to page 5
The SECCANT Range: Regenerative dryer for air and gas - 6

BAUER KOMPRESSOREN Custommade solutions with system engineering The appropriate configuration for each purpose. VERTICUS Range The four models 3, 3A, 4 and 4A of BAUER‘S SECCANT range offer a custom-made system solution for dehumidification as well as purifying air, inert gases and rare gases. When wiring in the conventional way up to three compressors can be connected to the SECCANT, when using a CAN-Bus as many compressors needed to obtain the maximum flow rate be connected. Interconnected operation can be achieved with help of the B-CONTROL using a CAN-Bus. Two SECCANT and 2 compressors...

Open the catalog to page 6
The SECCANT Range: Regenerative dryer for air and gas - 7

Storage System Bypass Filter System

Open the catalog to page 7
The SECCANT Range: Regenerative dryer for air and gas - 8

Technical Data SECCANT Flow rate max. l/min / scfm Nominal pressure bar /psig Regeneration air/gas volume % of the compressor flow Filter change intervals (drying) h Medical air acc. to European Pharmacy Regulations Industrial air acc.to DIN EN ISO 8573-1, Oil content class 3 Humidity class 3 Nitrogen / Rare gases SECCANT 3 SECCANT 3A SECCANT 4 SECCANT 4A Assuming proper maintenance and installation of the systems in accordance with operating instructions/ 2 operating manuals, and using the BAUER AERO-GUARD in cases where intake air CO2 concentration exceeds the levels required by the...

Open the catalog to page 8