Overview: This document provides technical specifications for fire-rated steel windows, specifically models B-30, A-0, A-60, H-60, and H-120. These windows are designed for installation in bulkheads and are constructed from coated mild or stainless steel.
Specifications:
  • Main Frame: Available in 4mm or 6mm thickness, suitable for welding or bolting to bulkheads.
  • Glass Panel: Sealed and condensation-free, ensuring clear visibility and durability.
  • Frames: Includes a fixing frame and an adjustable internal frame, which can be equipped with integrated venetian or roller blinds.
Options:
  • Roller Blinds
  • Electric Roller Blinds
  • Venetian Blinds
  • Sound Glass: Offers sound reduction ranging from 41dBRw to 48 - 62 dB.
Installation Details:
  • Welded Frame: Requires a cut-out size of clear opening plus 115mm.
  • Bolted Frame: Requires a cut-out size of clear opening plus 120mm.
Important Notes:
  • Dimensions provided are guidelines only. For project-specific information, refer to project drawings.
  • Technical changes may occur, and errors are reserved.
See more

Catalog excerpts

Fire rated windows-1

Fire rated window The window unit consist of a 4mm or 6mm main frame for welding or bolting to bulkhead, made of coated mild or stainless steel. A sealed condensation free glass panel, a fixing frame and an adjustable internal frame. The internal frame may be equipped with an integrated venetian or roller blind. Options: – Roller Blinds – Electric roller blinds Venetian Blinds Sound glass With reservation for errors and with rigths to make technical changes. Dimensions as guidelines only! For project specific information, always refer to project drawings and not the dimensions in this manual.

 Open the catalog to page 1
Fire rated windows-2

Fire rated Windows technical details WELDED FRAME Clear opening Main frame Wall thickness Fire glass Fixing frame Clear opening BOLTED FRAME Clear opening Main frame Wall thickness Fixing frame Internal liner Fire glass Clear opening With reservation for errors and with rigths to make technical changes. Dimensions as guidelines only! For project specific information, always refer to project drawings and not the dimensions in this manual.

 Open the catalog to page 2

All Baggerod AS catalogs and brochures

  1. HB-S

    5  Pages

  2. H-120S

    2  Pages

  3. HB-SB

    2  Pages

  4. HB-H, A-30

    2  Pages

  5. HB-H, A-60

    2  Pages

  6. H-0H

    2  Pages

  7. G007

    2  Pages

  8. HB-H A-30

    2  Pages

  9. HB-H / HB-HH

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.