PRE-28.MODBUS

PRE-28.MODBUS

PRE-28.MODBUS

Product catalog summary
Overview: The document provides detailed specifications and ordering information for the PRE-28.Modbus differential pressure transmitter, highlighting its features, technical data, and available configurations.
Specifications:
  • Communication Protocol: Digital Modbus RTU.
  • Safety Certifications: Intrinsic safety and explosion-proof certificates (ATEX, IECEx).
  • Accuracy: 0.1%.
  • Static Pressure Limit: Up to 413 bar.
  • Marine Certification: DNV, BV.
Technical Data:
  • Accuracy: ±0.1% of calibrated range.
  • Long-term Stability: Maintains accuracy for 3 years.
  • Thermal Error: < ±0.08% (FSO) / 10°C, max. ±0.3% (FSO) over the compensation range.
  • Thermal Compensation Range: -25 to 80°C.
  • Materials: Wetted parts and diaphragms made of 316L stainless steel; casing options include 304ss and 316ss.
  • Power Supply: 4 to 28 V DC, with specific requirements for Exia versions.
  • Output: MODBUS RTU or 4 to 20 mA.
  • Transmission Range: 1200 meters.
Measuring Ranges:
  • Various nominal measuring ranges from 0 to 70 bar down to -5 to 70 mbar, with specific minimum set ranges and rangeability ratios.
Ordering Procedure:
  • Model Code: PRE-28.Modbus with options for Exia and Exd versions, marine certificates, and specific services like oxygen or hydrogen service.
  • Process Connections: Options include C, CH, GP, and PN types with various thread specifications and materials.
  • Accessories: Mounting brackets and connectors for different pipe sizes and materials.
Applications: Suitable for environments requiring high accuracy and safety certifications, including marine and hazardous areas.
See more

Catalog excerpts

PRE-28.MODBUS-1

DIFFERENTIAL PRESSURE TRANSMITTER PRE-28.MODBUS ü Digital communication protocol Modbus RTU Intrinsic safety certificates (ATEX, IECEx) Explosion proof certificates (ATEX, IECEx) Static pressure limit up to 413 bar Marine certificate DNV, BV SGM (1/2"NPTM) cable connection IP68 (IP66 for gauge pressure <80bar) M20x1,5F thread (cable gland not included) APLISENS S.A. Produkcja Prze Aparatury Pom PRZETWORNI Numer fabrycz Zakres pomiar Sygnał wyjścio Zasilanie 54 GP type process connection PN type process connection C type process connection to mount with a valve manifold CH type process connection to mount with a valve manifo

 Open the catalog to page 1
PRE-28.MODBUS-2

Application The transmitters PRE-28.Modbus have two operating modes, configuration mode and Modbus mode. The configuration mode is used for changing settings and detailed diagnostics of the transmitter. In this mode you can also activate a current loop compatible with a 4-20 mA current output. Nominal measuring range (FSO) 0...70 bar (0...7 MPa) 0...16 bar (0...1,6 MPa) 0...2,5 bar (0...250 kPa) 0...1 bar (0...100 kPa) 0...0,25 bar (0...25 kPa) -0,5...0,5 bar (-50...50 kPa) -100…100 mbar (-10…10 kPa) -5...70 mbar (-0,5...7 kPa) Minimum set range 7 bar 1,6 bar 0,2 bar 50 mbar 10 mbar 0,1 bar 10...

 Open the catalog to page 2
PRE-28.MODBUS-3

Ordering procedure Model Description Smart differential pressure transmitter II 1/2G Ex ia IIC T4/T5/T6 Ga/Gb for PM12, PKD el. connection Ex ia IIC T4/T5/T6 Ga/Gb II 1/2G Ex ia IIC T4/T5/T6 Ga/Gb II 1D Ex ia IIIC T110°C Da I M1 Ex ia I Ma for SG el. connection Ex ia IIC T4/T5/T6 Ga/Gb IECEx Ex ia IIIC T105°C Da Ex ia I Ma II 2G Ex db IIC T6/T5/T4 Gb II 2D Ex tb IIIC T85°C/T100°C/T120°C Db for SGM and PZ2 Ex db IIC T6/T5/T4 Gb el. connection IECEx Ex tb IIIC T85°C/T100°C/T120°C D Marine certificate – DNV (not available in ALW and ALM version) For oxygen service (sensor filled with Fluorolube...

 Open the catalog to page 3

All APLISENS S.A. catalogs and brochures

  1. PEM-500

    4  Pages

  2. MS-100

    1  Page

  3. MS-100K

    1  Page

  4. PR - G

    2  Pages

  5. APR -2000G

    3  Pages

  6. APR-2000ALW/G

    3  Pages

  7. APM-2

    3  Pages

  8. APR-2000ALW

    7  Pages

  9. AS-dP

    1  Page

  10. PRE-28.SMART

    3  Pages

  11. APRE-2000

    3  Pages

  12. APCE-2000

    3  Pages

  13. AS

    1  Page

  14. PCE-28.MODBUS

    3  Pages

  15. PCE-28

    3  Pages

  16. PCE-28.SMART

    3  Pages

  17. APC-2000ALW

    5  Pages

  18. APC-2000ALM

    3  Pages

  19. PEM-1000

    4  Pages

  20. RH

    3  Pages

  21. ERH-xx-20

    2  Pages

  22. ERH-11-20

    1  Page

  23. ERH-SMALL

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.