AS-dP

AS-dP

Product catalog summary
Ordering Procedure:
The differential pressure transmitter AS-dP can be ordered using the format AS-dP /___/___/___/___, specifying the desired measuring range, output signal, and process connection.
Measuring Range:
Available ranges include 0 ÷ 1 bar, 0 ÷ 2.5 bar, 0 ÷ 4 bar, 0 ÷ 6 bar, 0 ÷ 10 bar, 0 ÷ 16 bar, and 0 ÷ 25 bar.
Output Signal:
The transmitter provides a 4 ÷ 20 mA output signal.
Process Connection:
Options include G1/2” and 1/4” NPTF connections.
Metrological Parameters:
  • Accuracy: 0.4%
  • Hysteresis and repeatability: 0.05%
  • Overpressure limit: 6 times the range, maximum 40 bar
  • Thermal compensation range: 0 ÷ 70°C
  • Thermal error: 0.2% per 10°C
  • Long-term stability: 0.5% per year
Technical Data:
  • Degree of protection: IP65
  • Material of process connection and diaphragms: 316 L stainless steel
  • Material of casing: 304 stainless steel
Electrical Parameters:
  • Output signal: 4 ÷ 20 mA, two-wire transmission
  • Power supply: 8 to 36 VDC
  • Load resistance for current output: 20 kΩ
  • Load resistance for supply output: 20 kΩ
Operating Conditions:
  • Operating temperature range (ambient): –25 ÷ 80°C
  • Medium temperature range: –25 ÷ 120°C for direct measurement, > 120°C using an impulse line
Electrical Connection:
Options include PD and PKD types with IP65 protection.
See more

Catalog excerpts

AS-dP-1

Differential pressure transmitter AS-dP ü Accuracy 0.4% ü Measuring ranges: 0 ÷ 1, 0 ÷ 2.5, 0 ÷ 4 bar 0 ÷ 6, 0 ÷ 10 bar 0 ÷ 16, 0 ÷ 25 bar Numer fabryczny Zakres pomiarowy Sygnał wyjściowy Zasilanie PKD type IP67 (3m of cable in standard) APLISENS S.A. Produkcja Przemysło Aparatury Pomiarowe Metrological parameters Accuracy Hysteresis, repeatability Overpressure limit Thermal compensation range Thermal error Long – term stability Electrical parameters Output signal 4 ÷ 20 mA, two wire transmission Power supply 8…36 VDC Load resistance Load resistance Technical data Degree of protection IP65 Material of process connection and diaphragms 00H17N14M2 (316 Lss) Material of casing 0H18N9 (304ss) Operating conditions Operating temperature range (ambient temp.) Medium temperature range –25 ÷ 80°C –25 ÷ 120°C – direct measurement > 120°C – measurement using an impulse line Ordering procedure AS-dP /___/___/___/___ Measuring range: 0 ÷ 1, 0 ÷ 2.5, 0 ÷ 4, 0 ÷ 6, 0 ÷ 10, 0 ÷ 16 or 0 ÷ 25 bar Electrical connection: PD or PKD

 Open the catalog to page 1

All APLISENS S.A. catalogs and brochures

  1. PEM-500

    4  Pages

  2. MS-100

    1  Page

  3. MS-100K

    1  Page

  4. PR - G

    2  Pages

  5. APR -2000G

    3  Pages

  6. APR-2000ALW/G

    3  Pages

  7. APM-2

    3  Pages

  8. APR-2000ALW

    7  Pages

  9. PRE-28.MODBUS

    3  Pages

  10. PRE-28.SMART

    3  Pages

  11. APRE-2000

    3  Pages

  12. APCE-2000

    3  Pages

  13. AS

    1  Page

  14. PCE-28.MODBUS

    3  Pages

  15. PCE-28

    3  Pages

  16. PCE-28.SMART

    3  Pages

  17. APC-2000ALW

    5  Pages

  18. APC-2000ALM

    3  Pages

  19. PEM-1000

    4  Pages

  20. RH

    3  Pages

  21. ERH-xx-20

    2  Pages

  22. ERH-11-20

    1  Page

  23. ERH-SMALL

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.