APR-2000ALW/G
3Pages

{{requestButtons}}

Catalog excerpts

APR-2000ALW/G - 1

SMART DIFFERENTIAL PRESSURE TRANSMITTER for low ranges APR-2000ALW/G ü 4...20 mA output signal + HART protocol ü Display with backlight ü Programmable range, zero shift, damping ratio and characteristic with local panel keys ü Selectable linear or radical conversion characteristic ü Accuracy from 0,1% osion Expl oof ü Intrinsic safety certificate (ATEX, IECEx) pr ate ic ü Explosion proof certificate (ATEX, IECEx) e c rtif ü Safety version SIL2/SIL3 APR-2000ALW/G - Aluminum epoxy painted casing APR-2000ALW/G/SS - Stainless steel casing APR-2000ALW/G Industrial Version, C type process connector to be mounted along with a valve manifold The APR-2000ALW/G transmitter is applicable to the measurement of differential pressure of gases. Typical applications include the measurement of blast pressure, chimney draughts or pressure / underpressure in furnace chambers. The ability to select the radical conversion characteristics enables the transmitter to be used in gas-flow measurement systems using reducing pipes or other impeding elements. The transmitter can withstand overpressure up to 1 bar. The housing of the electronic circuit has the degree of protection IP66/IP67. Communication with the transmitter is carried out with a KAP-03 communicator, some other Hart communicators or a PC with an Hart/USB converter and RAPORT 2 configuration software. Configuration, calibration The economical version can be mounted on any stable construction using the mounting bracket. The transmitter’s connection shanks have terminals to be connected to the elastic Æ6×1 impulse line. Where the pulse comes through a metal pipe, we suggest an M20×1.5 adapter for a Æ6×1 fitting using. The following metrological parameters can be configured: ¨ The units of pressure, ¨ Start and end-points of measuring range, damping time constant, ¨ Conversion characteristic (radical, inversion, user’s nonlinear characteristic). Ability to calibrate the transmitter with reference to a standard pressure. APR-2000ALW/G Economic Version, process connection with terminal connecting to Æ6 pipe (PCV type) Additionally, the data interchange with the transmitter enables the users to identify the transmitter, read the currently measured pressure difference value, output current and percentage of measuring range. The transmitter with a C type connector should be mounted on a 3- or 5-valve manifold. We recommend use VM type

Open the catalog to page 1
APR-2000ALW/G - 2

Operating guidelines The transmitter should be mounted in a vertical position. The impulse lines should be connected in such a way that any condensed liquids flew off away from the device. Where there is a significant difference in height between the place where the transmitter is mounted and the place where the pulse is taken, the measurement may vary with the temperature of the impulse line. Connecting a compensating pipe close to the impulse line, from the transmitter's reference connection shank to the height at which the impulse is taken can minimise this effect. To prevent dust from...

Open the catalog to page 2
APR-2000ALW/G - 3

Ordering procedure Model APR-2000 Description Smart differential pressure transmitter With display, output 4-20mA + Hart With display, output 4-20mA + Hart, Functional Safety certificate according to PN-EN 61508:2010 parts 1 ÷ 7, PN-EN 61511-1:2017 + PN-EN 61511-1:2017/A1:2018-03, PN-EN 62061:2008 + PN-EN 62061:2008/A1:2013-06 + PN-EN 62061:2008/A2:2016-01 Nominal measuring range Measuring set range Process connections Electrical connection Other specification Stainless steel housing II 1/2G Ex ia IIC T4/T5 Ga/Gb IECEx Ex ia IIC T4/T5 Ga/Gb II 1/2G Ex ia IIC T4/T5 Ga/Gb II 1D Ex ia IIIC...

Open the catalog to page 3

All APLISENS S.A. catalogs and brochures

  1. PEM-500

    4 Pages

  2. MS-100

    1 Pages

  3. MS-100K

    1 Pages

  4. PR - G

    2 Pages

  5. APR -2000G

    3 Pages

  6. APM-2

    3 Pages

  7. APR-2000ALW

    7 Pages

  8. AS-dP

    1 Pages

  9. PRE-28.SMART

    3 Pages

  10. APRE-2000

    3 Pages

  11. APCE-2000

    3 Pages

  12. AS

    1 Pages

  13. PCE-28

    3 Pages

  14. PCE-28.SMART

    3 Pages

  15. APC-2000ALW

    5 Pages

  16. APC-2000ALM

    3 Pages

  17. PEM-1000

    4 Pages

  18. RH

    3 Pages

  19. ERH-xx-20

    2 Pages

  20. ERH-11-20

    1 Pages

  21. ERH-SMALL

    2 Pages