PAN45PH1_001_09-07-2020
4Pages

{{requestButtons}}

Catalog excerpts

PAN45PH1_001_09-07-2020 - 1

PHASE ROTATION CONTROLLER Protection against : - reverse phase rotation. - overvoltages and undervoltages. - the voltage differences between phases due to loss of neutral or asymmetry. (Over / undervoltage protection usable in a single-phase) FRANCE Multicolored LEDs Quick connect cable provided Display on cabinet door in very low voltage (5V isolated) PH1 PAN45-01-00 48x48 DIN format The three-phase power grid controller makes it possible to protect the installation BEFORE and AFTER starting up against an always possible failure of the power grid. CHARACTERISTICS: It constantly monitors : - the presence of the 3 phases and the direction of rotation. - the undervoltage and overvoltage of each of the phases. - the asymmetry of each phase and loss of neutral. He rocks : - an adjustable delayed shutdown when exceeding the setting. - an instantaneous shutdown in the event of an abnormally high overshoot. The set includes : - a box to be mounted inside the cabinet on a symmetrical DIN rail. - a DIN 48x48 display unit equipped with 4 very high brightness LEDs. (delivered with an extra flexible connection cord equipped with 2 RJ45 connectors). In «three-phase without neutral» use, it effectively protects the motors and all elements. In «three-phase with neutral» use, it provides protection against loss of neutral for PH/N powered elements. It also allows a display outside the cabinet in «very low voltage» security. With an intuitive display, it indicates: - the presence of the 3 phases with the clockwise or anti-clockwise direction of rotation. - the undervoltage and overvoltage of each of the phases. - asymmetry or loss of neutral. - the status of the output (possible use of the power grid or not). The PH001 is mounted inside the cabinet on a symmetrical DIN rail. Power supply : PH001 is self-powered by the controled inputs C . It monitors the power grid as soon as there is any phase and neutral or any two phases. In the event of loss of supply or insufficient supply, the output relay is deactivated (positive safety). It includes : A - 4 LEDs for signaling the operation. B - 4 potentiometers for setting the limits. C - 1 removable 4-points terminal block for connecting the 3 phases and the optional neutral. D D - 1 removable 3-points terminal block for connection of the positive safety relay output contact with 1RT contact. E - 1 RJ45 connector powered by 3kV isolated optocouplers, for connecting the LEDs to the remote PAN45-01-00. - 1 switching power supply, isolated at 1kV, intended to supply the remote light box, the B PAN45-01-00. In front : - 4 LEDs: the first 3 LEDs (L1, L2, L3) are used to display the state of each phase and direction of rotation. The 4th LED (Status) displays whether the power grid is usable or not, as well as the type of fault found. (see next page, the different possible displays) - 4 adjustment potentiometers: overvoltage, undervoltage, asymmetry / loss of phase and time delay. - An RJ45 socket isolated by optocoupler and by internal switching power supply.

Open the catalog to page 1
PAN45PH1_001_09-07-2020 - 2

The colors of the LEDs PH1, PH2, PH3 are selectable. 7 colors possible. The PAN45-01-00 allows you to indicate the installation status, without having to open the cabinet door. It is intended to report the display states on the front while ensuring galvanic separation from the power grid. The front IP65 safety box is supplied with «very low voltage» (5Vdc by 1kV isolated converter and 3kV optocouplers located in the PH001 box). RJ45 cable standard length : 2.00m In DIN 48x48 format, with bracket mounting, it has 4 high-brightness LEDs. The first 3 LEDs are used to display the state of each...

Open the catalog to page 2
PAN45PH1_001_09-07-2020 - 3

Phase rotation: As soon as the power is turned on and during the entire operating period, the system checks the presence and direction of phase rotation. - If the detected direction is anti-clockwise (known as reverse rotation): the relay will be immediately deactivated in order to prevent incorrect rotation of the motors. The display of LEDs 1/2/3 will be in running light effect, LED 4 will be red steady. The relay will only be activated after checking the correct Anticlockwise rotation and after carrying out the other checks. - If the detected direction is clockwise: the rest of the...

Open the catalog to page 3
PAN45PH1_001_09-07-2020 - 4

CONNECTIONS: Three-phase connection with or without neutral Raccordement triphasé avec ou sans neutre L1 Single-phase connection Raccordement monophasé Protection by 3 fuses is compulsory. Crossing neutral with a phase can destroy the device. If the neutral is used in the installation protected by the PH001, connection of the neutral is compulsory. CHARGE LOAD CHARGE LOAD The voltage indication is indicated PH / PH In single-phase, the «overvoltage» and «undervoltage» as well as «time delay» detections are active. Phase rotation and asymmetry / loss of neutral are inactive. Commissioning: -...

Open the catalog to page 4

All A.M.I. catalogs and brochures

  1. Catalogue

    82 Pages