Catalog excerpts
Alfa Laval PureBallast 3.1 Ballast water treatment system Alfa Laval PureBallast 3.1 is an automated inline treatment system for the biological disinfection of ballast water. Operating without chemicals, it combines initial filtration with an enhanced form of UV treatment to remove organisms in accordance with IMO and USCG limits. The main component of the modular system is an enhanced UV reactor in which disinfection treatment occurs. The special design of the reactor’s synthetic quartz lamp sleeves supports transmission of a broader wavelength spectrum, providing 10% more UV light during disinfection. Combined with the reactor’s internal design, this ensures optimal UV dosage and low energy consumption. Application PureBallast 3.1 is designed for ballast water treatment in all types of water: fresh, brackish and marine. Upon request, it can also be configured as a two-water solution for brackish and marine water. Flows of 32-3000 m3/h can be accommodated by a standard system. Due to its enhanced UV technology and power ramp-up capabilities, PureBallast 3.1 provides unmatched biological disinfection performance in low-clarity waters. Full-flow treatment is possible in waters where the UV transmittance is as low as 42%.
Open the catalog to page 1Benefits • Superior performance in any waters PureBallast 3.1 offers unmatched biological disinfection performance in any type of water: fresh, brackish or marine. This includes water in liquid form at frigid temperatures. Even in low-clarity waters with UV transmission of just 42%, the system performs at full flow. This gives vessels full freedom of movement without operating constraints. • Effective power management Because of its high biological disinfection performance, PureBallast 3.1 runs at just 50% of its potential operating power in most situations. It can be ramped up to full...
Open the catalog to page 2System components – biological disinfection Biological disinfection with PureBallast 3.1 comprises an initial filtration stage followed by enhanced UV treatment in a specially designed reactor. Both stages are integrated into the ballast water piping as inline components. • Filter A filter is used during ballasting operations to block the intake of larger organisms and reduce sediment in the ballast water tanks. Bypassed during deballasting, the filter is cleaned via automatic backflushing using a small portion of the system flow. Two filter types are available: - Basket filter design...
Open the catalog to page 3Operating sequence • Ballasting PureBallast 3.1 is a fully automated system. When initiated, it undergoes a brief startup sequence. When ballasting begins, the incoming ballast water first passes through the filter stage. This removes any larger organisms and particles, which improves the quality of the water for treatment. The filter stage is of benefit for operation in cloudy coastal waters and fresh water. After filtration the water continues through the reactor stage, where it is disinfected by means of enhanced UV before entering the ballast water tanks. Once ballasting is complete,...
Open the catalog to page 4Technical data Power consumption, 170 m3/h reactor Optimal 11 kW (20 kW at full ramp-up*) Power consumption, 300 m /h reactor Optimal 17 kW (32 kW at full ramp-up*) Power consumption, 600 m3/h reactor Optimal 32 kW (63 kW at full ramp-up*) Power consumption, 1000 m /h reactor Optimal 52 kW (100 kW at full ramp-up*) Power supply Working pressure Capacity range The size of a PureBallast 3.1 system is determined by the capacity of the ballast water pumps it is used with. An optimal configuration is achieved by match ing a reactor setup and filter capacity to the required ballast water flow....
Open the catalog to page 5Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions. Our equipment, systems and services are dedicated to helping customers to optimize the performance of their processes. Time and time again. We help our customers to heat, cool, separate and transport products such as oil, water, chemicals, beverages, foodstuffs, starch and pharmaceuticals. Alfa Laval reserves the right to change specifications without prior notification. How to contact Alfa Laval Up-to-date Alfa Laval contact details for all countries are always available on our...
Open the catalog to page 6All Alfa Laval Mid Europe catalogs and brochures
-
i-40D
4 Pages
-
PureBilge
20 Pages
-
Lube oil filter – 350 series
3 Pages
-
Eliminator – CCU
4 Pages
-
Vibration dampers
2 Pages
-
F-152
4 Pages
-
Alfa Laval 290 Filter
4 Pages
-
AlfaBlue Junior DG
16 Pages
-
EPC 60 Retrofit
2 Pages
-
Alfa Laval three-screw pump
6 Pages
-
High Efficiency Evaporator
4 Pages
-
Always a step ahead
12 Pages
-
A new tide of savings
12 Pages
-
Desalt DPU-2-36-C Series
4 Pages
-
PureNOx Prime
4 Pages
-
LPG carriers
2 Pages
-
LNG carriers
2 Pages
-
Alfa Laval AC16 / ACH16
2 Pages
-
Alfa Laval AC112 / ACH112
2 Pages
-
Alfa Laval AC500DQ /ACH500DQ
2 Pages
-
PureNOx
2 Pages
-
Marine Essentials
100 Pages
-
Fincoil Solar Max
10 Pages
-
Aalborg TFO
10 Pages
-
Tank equipment for hygienic use
12 Pages
-
Aalborg OC
2 Pages
-
Aalborg D
2 Pages
-
ALF - Alfa Laval Filter
4 Pages
-
Aalborg KBE
2 Pages
-
Central cooling - T35
2 Pages
-
Ball valve UltraPure
4 Pages
-
Crushers and depitters
4 Pages
-
Compabloc
4 Pages
-
AlfaBlue BXM/BXD
2 Pages
-
Alfa-v-single-row-vxm
2 Pages
-
Alfa-V ACV
2 Pages
-
PureSOx
16 Pages
-
PureDry
4 Pages
-
PureBallast 3.0
6 Pages
-
Heating Insulation
2 Pages
-
Cooling Insulation Type P
2 Pages
-
CB100 / CBH100
2 Pages
-
Alfa Laval AOT 3F
2 Pages
-
AlfaRex - TM20
2 Pages
-
AlfaDisc
2 Pages
-
AlfaCond range
2 Pages
-
Eliminator CCU
4 Pages
-
Advanced Cooling System
4 Pages
-
MIB 303
4 Pages
-
EMD00062EN Emmie
2 Pages
-
PureBilge system
38 Pages
-
Here30_ENG.pdf
36 Pages
-
MOPX Separation Systems
4 Pages
-
Plate heat exchanger
2 Pages
-
Lubricating oil filter
4 Pages
-
Desalt DPU-36-C Series
4 Pages