DT800 Tilted Element Thru-hull
2Pages

{{requestButtons}}

Catalog excerpts

DT800 Tilted Element Thru-hull - 1

The Smart Alternative! Airmar's D800 and DT800 Smart™ Sensors feature embedded micro-electronics. Depth and temperature signals are processed inside the sensor and can be displayed on any radar, chart plotter, or device that accepts NMEA 0183 or NMEA 2000® data The 235 kHz frequency prevents mutual interference with other echosounders on the vessel. Angle for Results The DT800 Tilted Element Transducer's low-profile housing compensates for hull deadrise. The unique design tilts the ceramic element inside the transducer housing—giving all the advantages of a fairing block without a hull protrusion. Designed with Airmar's exclusive Broadband Ceramic Technology, the 235 kHz element improves resolution without sacrificing sensitivity. The higher power rating 100 W RMS provides spot-on depth readings in as little as 0.5 m (1.6') of water and can reach depths up to 180 m (600'). Tilted Element™ Thru-Hull Smart™ Sensors Features ■ Tilted-Element Broadband-Ceramic versions available in a 0° or 12° or 20° tilt ■ Available in NMEA 0183 and NMEA 2000® versions ■ 235 kHz frequency prevents mutual interference with other echosounders on the vessel ■ Temperature sensor in DT800 models ■ Cable lengths up to 100 m (330') are possible with no loss of performance—NMEA 0183 only ■ Plastic, bronze, or stainless steel housings available ■ Retractable housing with water valve ■ Available in low-profile, countersunk, or beveled-edge housings

Open the catalog to page 1
DT800 Tilted Element Thru-hull - 2

D800, DT800 Technical Information 235 kHz Non-Broadband / Broadband Weight: —0.9 kg (2 lb)—Plastic —1.5 kg (3.4 lb)—Bronze —1.6 kg (3.6 lb)—Stainless Steel Acoustic Window: Urethane Data Update Rate: 1 per second Minimum Depth Range: 0.5 m (1.6') Maximum Depth Range: —Up to 100 m (330')—Non-Broadband —Up to 180 m (590')—Broadband Pressure Rating: 3 m (10') Supply Voltage: — 10 VDC to 25 VDC—NMEA 0183 —9 VDC to 16 VDC—NMEA 2000 Supply Current: — <40 mA—NMEA 0183 — <200 mA—NMEA 2000 Standard Cable Length: — 10 m (33)—NMEA 0183 —6 m (20') devicenet—NMEA 2000 Temperature Accuracy: ±0.5°C...

Open the catalog to page 2

All Airmar catalogs and brochures

  1. EchoRange

    4 Pages

  2. Thru-Hull

    6 Pages

  3. G2183

    2 Pages

  4. DST800

    2 Pages

  5. M563

    2 Pages

  6. TM165HW

    2 Pages

  7. TM260

    2 Pages

  8. M260

    2 Pages

  9. P74

    2 Pages

  10. B744V B744VL

    2 Pages

  11. P32

    2 Pages

  12. DX900+

    2 Pages

  13. TDT1000

    2 Pages

  14. CAST App

    2 Pages

  15. 110WX, 200WX

    4 Pages

  16. WXS Series

    2 Pages

  17. 200WX-IPX7

    2 Pages

  18. 220WXH

    4 Pages

  19. SS510 Survey

    2 Pages

  20. T80

    2 Pages

  21. P8 Thru-hull

    2 Pages

  22. P7 Thru-hull

    2 Pages