FLANGEMOUNT 3" BLOWER 115 VOLT AC FEATURES • Tough Reinforced Plastic Housing • Continuous-Duty Motor with Thermal Overload Protection • Mounts To Any Flat Surface • Slip-On Inlet Ducting Connection • Efficient High Volume Air Flow • Low Current Draw • Corrosion-Resistant Materials Throughout For an exposed inlet, the chrome plated ventilator intake screen number 34764-0000 provides a safe and attractive means of protecting the inlet. The blower may also be mounted with the inlet port through a bulkhead by using intake collar number 34943-0000 to convert the 3" intake port to a flange configuration. NOTICE: Blower should be mounted away from extreme heat Fuse Size: Weight: APPLICATION The Jabsco 115 Vac blower is ideal for ventilating cabin odors which may be present in galleys, heads or locker areas. It may also be used for engine room ventilation on vessels with diesel powered engines only. THIS BLOWER IS NOT IGNITION PROTECTED. DO NOT USE TO EXHAUST FLAMMABLE VAPORS SUCH AS GASOLINE FUMES OR MOUNT IN AN AREA WHICH MAY CONTAIN FLAMMABLE VAPORS. The blower is also suitable for general air circulation when 115 Vac power consumption is preferred. MOUNTING: The blower housing flange should be mounted on a flat bulkhead surface. Selection of a dry cool location will prolong motor life. If mounting blower in a location where spray into discharge port may occur, mount blower with motor in a vertical orientation (see installation drawing). When location is selected, cut a 2-3/4" hole through bulkhead to align with discharge port of blower. Secure discharge port flange to bulkhead using #10 screws and flat washers. Tighten screws evenly to avoid flange damage. If discharged air is to be directed to a vent by means of 3" ducting, install an outlet collar number 34856-0000 on the side of the bulkhead opposite blower (as illustrated in installation drawing). 3" flexible ducting number 34959-0100 is easy to cut and install providing a simple means of directing air to the appropriate discharge vent. Use a suitable vent fitting so blower static pressure will not be affected by external wind conditions. If 3" ducting is used to direct air to the blower inlet, route the ducting with as few bends as possible. Explosion hazard. Motor can spark. Explosion & death can occur. Do not use where flammable vapors are present. (more than 130°F) to prevent distortion of blower wheel or housing. WIRING: All wiring should be done by a qualified electrician and conform with USCG regulations. A minimum of 16 gauge THW wire should be used for lengths of up to 50 feet from the power source. The ungrounded (black) conductor may include a 0.75 Amp AGC fuse installed near the power source to protect the circuit. A switch of minimum 5 Amp rating may also be installed in ungrounded conductor (between fuse and blower) to control blower operation. The neutral conductor (white) should be connected directly from the neutral buss to the blower motor. A separate ground wire (green) should be secured to the ground- 3" Ducting 34959-0100 To Discharge Vent Outlet collar 34856-0000 for 3" ducting Inlet Ducti
カタログの1ページ目を開く
Motor Kit 115 Vac with 2 Mounting Nuts Blower Housing Blower Wheel Blower Housing Screw 8 x 5/8 SS Self Tapping Pan Head Part Number MARINE SWITCH PANEL BILGE BLOWER THE PRODUCT DESCRIBED HEREIN IS SUBJECT TO THE JABSCO ONE YEAR LIMITED WARRANTY, WHICH IS AVAILABLE FOR YOUR INSPECTION UPON REQUEST. USA Jabsco is a trademark of Xylem Inc. or one of its subsidiaries. © 2012 Xylem, Inc. 43000-0400 Rev C 10/2012
カタログの2ページ目を開くXylemのすべてのカタログとパンフレット
-
Jabsco Marine Toilets
16 ページ
-
Oil_Change_Diesel
6 ページ
-
Flexible Impeller Pumps
54 ページ
-
Oscillating Pumps 07
2 ページ
-
Rotary Lobe Pumps 06
3 ページ
-
Washdown Pumps
2 ページ
-
Water Pressure Systems
10 ページ
-
Toilet Systems
14 ページ
-
Bilge Pumping Systems
24 ページ
-
Speciality Products
5 ページ
-
Sliding Vane Pumps
5 ページ
-
Oscillating Pumps
2 ページ
-
Rotary Lobe Pumps
3 ページ
-
Hand Pumps
2 ページ
-
Gear Pumps
2 ページ
-
Diaphragm Pumps
15 ページ
-
Centrifugal Pumps
19 ページ
-
MODEL 34754-0000
2 ページ
-
4125 SERIES
4 ページ
-
4105 series
4 ページ
-
2760-SERIES
2 ページ
-
Exploded View
2 ページ
-
Impeller Replacement
10 ページ
-
Searchlights
8 ページ
-
Ventilation Blowers
4 ページ
-
Oil Change & Diesel
6 ページ
-
Washdown Pumps
2 ページ
-
Water Pressure Systems
10 ページ
-
Toilet Systems
12 ページ
カタログアーカイブ
-
Bilge Pumping Systems
26 ページ
-
Service Parts
80 ページ
-
Impeller Replacement
16 ページ
-
Searchlights
12 ページ
-
Oil Change & Diesel
10 ページ
-
FLOJET BevJet
12 ページ
-
General Purpose Pumps
14 ページ
-
OVERVIEW OF PARTS
2 ページ
-
Type III MSD Waste
18 ページ
-
52600 Series
18 ページ
-
SELF-PRIMING
4 ページ
-
VENTED LOOP SOLENOID
1 ページ
-
Par-Max Series
2 ページ
-
Jabsco
2 ページ
-
Marine Product Guide
24 ページ
-
Brochure
4 ページ