PA-13 Data sheet
1 / 8ページ

{{requestButtons}}

カタログの抜粋

PA-13 Data sheet - 1

PA-13 Scan for more information

カタログの1ページ目を開く
PA-13 Data sheet - 2

Table of Contents Specifications Dimensions Speed/Current vs Load Connectors & Feedback Have any queries? Our expert engineers are here to help! sales@progressiveautomations.com

カタログの2ページ目を開く
PA-13 Data sheet - 3

Stroke Limit Switch Limit Switch Feedback Screw Type Motor Type Connector Type Wire Length Housing Material Rod Material Gear Material Color (Shaft) Color (Motor End) Noise Duty Cycle Overload Protection Operational Temperature Protection Class Feedback Options Certiffications Mounting Brackets Mounting Ends Features Speed (inch/sec) No Load Full Load 0.24 0.16 0.31 0.47 0.47 0.79" to 40" Internal - Non-Adjustable Customizable ACME Screw, Ball Screw Brushed DC Motor See Page 6 40" (customizable) 6062 Aluminum Alloy Stainless Steel Powder Metallurgy Steel Alloy Silver Graphite <90dB 20% (4...

カタログの3ページ目を開く
PA-13 Data sheet - 4

Dimensions (Dimensions in inches) For Stroke Length less than 4" For Stroke Length 12" and Greater For Stroke Length of 4" and Greater For Stroke Length greater than 24"

カタログの4ページ目を開く
PA-13 Data sheet - 5

Speed vs Load Speed vs. Load: PA-13 Linear Actuator 12VDC 1.6 1.4 Speed (inches/second) Current vs Load Current vs. Load: PA-13 Linear Actuator 12VDC 25

カタログの5ページ目を開く
PA-13 Data sheet - 6

Speed vs Load Speed vs. Load: PA-13 Linear Actuator 24VDC 1.6 1.4 Speed (inches/second) Current vs Load Current vs. Load: PA-13 Linear Actuator 24VDC 12

カタログの6ページ目を開く
PA-13 Data sheet - 7

Connectors & Feedback 2-Pin Connector (Standard) Motor Part Name Part Number Mating Part Number Tyco Electronics AMP Universal Mate-N-Lok PLUG Hall Effect Wires Hall Effect equipped actuators will come with tinned wire leads and no connector. Hall Sensor Signal 2 Leads when Extending Signal 1 Leads when Retracting Output Signal Extending Output Signal Retracting Hall Effect 1 Signal Hall Effect 2 Signal Hall Effect 1 Signal Hall Effect 2 Signal Force (lbs) Resolution (pulses/inch) Potentiometer Specifications *For Stroke Length up to 6" Signal *Actual resistance value may vary within the...

カタログの7ページ目を開く
PA-13 Data sheet - 8

Features Manual Override Operation The manual override can be carried out while the PA-13 actuator is loaded if the load experienced was below the maximum load specifications (3000lbs). To operate manual override: 1. Shut down power or disconnect the actuator from power. 2. Remove the Torx screw located in the back center of the actuator. 3. Insert a 6mm hex key into the hole. 4. Turn the hex key clockwise to retract the actuator. For extending the actuator, turn the hex key counterclockwise. 5. When finished with manual override, remove the hex key, and screw the Torx screw back in place.

カタログの8ページ目を開く

Progressive Automationsのすべてのカタログとパンフレット

  1. FLTCON-3

    3 ページ

  2. PA-CB1-4

    2 ページ

  3. PA-28

    3 ページ

  4. PA-33

    3 ページ

  5. PA-25

    3 ページ

  6. FLTCON-2

    4 ページ

  7. PA-31

    3 ページ

  8. PA-22

    2 ページ

  9. FLTCON-4

    3 ページ

  10. FLTCON-1

    3 ページ

  11. PA-20

    2 ページ

  12. PA-30

    3 ページ

  13. PA-04 Data sheet

    10 ページ

  14. FLT-11 Data sheet

    8 ページ

  15. PA-01 Data sheet

    7 ページ

  16. PA-06 Data sheet

    7 ページ