Power Management Controller NORISYS 4 PMC - for Parallel Operation, Power Supply and System Protection The NORISYS 4 PMC - Power Management Controller - was deve- NORISYS 4 expansion unit, also used as an autarkic system loped as part of the NORISYS 4 control components in the auto- Optional expansion with NORISYS 4 modules mation platform. Optional connection of colour touch panel for observation and control purposes The power management unit is used as an independent control USB port for servicing purposes system with an optional colour touch panel and can be expan- RS-485 for NORISYS 4 ExtBus communication ded to form a high-level system with further components of the Generator set control with automatic start/stop function Parallel and isolated operation Automatic synchronisation Generator protection functions, 3-phase cessor with DSP functionality. In its basic version, the PMC is used Power supply protection function, 3-phase to switch generators to the power grid and is also suitable for use in stand-by power supply facilities. The system is designed to be used for isolated and parallel operation. An automatic start and synchronisation function is additionally implemented to accelerate the generator, set to nominal speed as well as to synchronise and close the power circuit breaker. The power requirements are defined by a higher-level system. An automatic facility that controls load balancing, opening of the power circuit breaker and stopping of the propulsion system is also integrated for the purpose of shutting down the generator. The Power Management Controller is equipped with an integrated power supply and system protection function.

カタログの1ページ目を開く
Flyer NORISYS 4 PMC - Power Management Controller - 2

Discrete Signals Discrete Signals Discrete Signals NORISYS 4 PMC - Inputs J3 x system voltage (up to 385 V AC) J3 x generator voltage (up to 385 V AC) J3 x generator current transformer up to 5A AC x speed pick-up J2 x analogue input (0 ... 20 mA, 4 ... 20 mA, 0 ... 10 V, +10 V ... -10 V) J1 x battery voltage (32 V) J1 x oxygen sensor voltage for system with mixture control J1 x potentiometer J10 x digital input, 1-pole NORISYS 4 PMC - Outputs J2 x analogue output (0 ... 20 mA, 4 ... 20 mA, 0 ... 5 V, +/-5 V, 0 ... 10 V, +/-10 V) J10 x digital output, 1-pole NORISYS 4 PMC - Communication...

カタログの2ページ目を開く

NORIS Group GmbHのすべてのカタログとパンフレット

  1. Datasheet TAV131

    3 ページ

  2. Datenblatt VFS5

    2 ページ

  3. Datasheet PAx9

    6 ページ

  4. Datasheet RG5

    2 ページ

  5. Datasheet VFW5

    2 ページ

  6. Datasheet NIR3 NIQ3

    20 ページ

  7. Datasheet VD61

    6 ページ

  8. Datasheet FA13

    14 ページ

  9. Datasheet NIQ31

    16 ページ

  10. Datasheet FA54

    11 ページ

  11. NORIS Brochure

    15 ページ

  12. Datasheet EOT

    6 ページ

  13. Datasheet DWA

    4 ページ

  14. Datasheet TP23

    4 ページ

  15. Datasheet VF5

    2 ページ

  16. Datasheet RFW5

    2 ページ

  17. Datasheet RTK5

    2 ページ

  18. Datasheet RFJ5

    2 ページ

  19. Datasheet VTK5

    2 ページ

  20. Datasheet RF5

    2 ページ

  21. Datasheet RI5

    2 ページ

  22. Datasheet RFG5

    2 ページ

  23. Datasheet VPT5

    2 ページ

  24. Datasheet RH5

    2 ページ

  25. Datasheet VFS5

    2 ページ

  26. Datasheet RH41M

    2 ページ

  27. Datasheet RW5

    2 ページ

  28. Datasheet VMP70

    3 ページ

  29. Datasheet VP5

    2 ページ

  30. Datasheet NADS3

    2 ページ

  31. Datasheet NAD2

    2 ページ

  32. Datasheet NAD1

    2 ページ

  33. Flyer NORISYS 4

    2 ページ

カタログアーカイブ

  1. Datasheet GE12

    2 ページ

  2. Datasheet GE14

    2 ページ