
グループ: Noris Group
カタログの抜粋

Measuring transducer for frequency, input sinusoidal signal 1 2 • Straightforward application Messbe Meas.Rangreich: e: Umgeb. Amb. Tem Temp: p: • Compact construction • Galvanic isolation between sensor input and output signal to the operating voltage Measuring Transducers • Suitable for severe operating conditions • Frequency ranges to suit customer requirements • Provision made for fine adjustment of measuring range • Anti-tamper seal for the fine adjustment • Meet high EMC-requirements • Short-circuit-proof output selectable from • Operating characteristics displayed by integrated LED • Flame-inhibiting and self-extinguishing body • Suitable tacho-generators are available (NORIS devices GE..) Measuring transducers of series 5 Measuring transducers of the Series 5 are designed to convert electric input values into standardised output signals. Principle of operation: The transducer signal measured at the converter input is converted into a standardised output signal that is proportional to the input and lends itself to further customised processing, for instance, in a machine controller. General notes on Type VFS5.., VFG5.. Description VFS5.., VFG5.. • Signal input for a sinusoidal frequency signal Electric isolation Sensor input and output signals are electrically isolated from • Suitable to evaluate outputs of speed pickups; the operating voltage. Multiple operation of amplifiers and evaluation AC-tacho-generators with various signal amplitudes devices is therefore possible at the same operating voltage. The • Suitable to evaluate outputs of NORIS sensor only supplies one amplifier device. GE..-tacho-generator-series with VFG5.. Output signal • Input range: 0 ... 10.000 Hz (according to type) • Maximum range fequency between: 50 ... 100 Hz (VFx500..), The output signal generated is a standardized voltage of 0 ... 10 V/DC or 2 ... 10 V/DC or, respectively, a standardized current of 0 ... 20 mA or 4 ... 20 mA. The output signal follows the input signal (Factory-set frequency adjustment) To avoid triggering errors the frequency full range set in factory strictly linearly (deviation < 0.1%). The output signal can be used to supply additional devices, such must be the highest frequency of the measuring chaine. as indicating instruments and limit-value switches. Attention should Input signal VFS5... be paid to the maximum driver capability of the output. Operating status display by LED The green LED will be lit when the operating voltage is applied and the dev
カタログの1ページ目を開く
Technical Data Series VFS5.., VFG5.. UO=9 ... 32 V/DC, UR=24 V/DC < 20% UO Integrated 2.5 times UR up to 2 ms 100% up to 10 ms Operating voltage Ripple Reverse voltage protection Overvoltage Voltage drops Power consumption Galvanic isolation Approx. 50 mA (24 V/DC) Between sensor input and output signal to the operating voltage Input signal Sinusoidal signal, NORIS tacho-generator GE Input overloading Input resistance Output VFx5..-G. 1.25 times input signal Noise voltage Error class Temperature sensitivity Voltage sensitivity Load sensitivity Reaction time Vibration resistance Shock...
カタログの2ページ目を開くNORIS Group GmbHのすべてのカタログとパンフレット
-
Unique Yacht Automation
16 ページ
-
Datasheet TAV131
3 ページ
-
Datasheet PAx9
6 ページ
-
Datasheet RG5
2 ページ
-
Datasheet VFW5
2 ページ
-
Datasheet RP5, RPT5
2 ページ
-
Datasheet NIR3 NIQ3
20 ページ
-
Datasheet VD61
6 ページ
-
Datasheet FA13
14 ページ
-
Datasheet NIQ31
16 ページ
-
NORIS Marine Overview
13 ページ
-
Datasheet FA54
11 ページ
-
NORIS Brochure
15 ページ
-
Datasheet TP31 TH31
5 ページ
-
Datasheet EOT
6 ページ
-
Datasheet DWA
4 ページ
-
Datasheet TP23
4 ページ
-
Datasheet VF5
2 ページ
-
Flyer NORISYS 4 CPU
2 ページ
-
Datasheet RFW5
2 ページ
-
Datasheet RTK5
2 ページ
-
Datasheet RFJ5
2 ページ
-
Datasheet VTK5
2 ページ
-
Datasheet RF5
2 ページ
-
Datasheet RI5
2 ページ
-
Datasheet RFG5
2 ページ
-
Datasheet VPT5
2 ページ
-
Datasheet RH5
2 ページ
-
Datasheet VFS5
2 ページ
-
Datasheet RH41M
2 ページ
-
Datasheet RW5
2 ページ
-
Datasheet VMP70
3 ページ
-
Datasheet VP5
2 ページ
-
Datasheet NADS3
2 ページ
-
Datasheet NAD2
2 ページ
-
Datasheet NAD1
2 ページ
-
Flyer NORISYS 4
2 ページ
カタログアーカイブ
-
Datasheet GE12
2 ページ
-
Datasheet GE14
2 ページ