
グループ: Noris Group
カタログの抜粋

Measuring transducer for frequency, input NORIS standard signal 1 2 • Straightforward application • Galvanic isolation between sensor input and Umgeb. Amb. Temp Temp: : and operating voltage to the output signal Measuring Transducers • Suitable for severe operating conditions • Compact construction • Frequency ranges to suit customer requirements • Provision made for fine adjustment of measuring range • Anti-tamper seal for the fine adjustment • Meet high EMC-requirements • Short-circuit-proof output selectable from • Operating characteristics displayed by integrated LED • Flame-inhibiting and self-extinguishing body • Suitable speed sensors are available Measuring transducers of series 5 Measuring transducers of the Series 5 are designed to convert electric input values into standardised output signals. Principle of operation: The transducer signal measured at the converter input is converted into a standardised output signal that is proportional to the input and lends itself to further customised processing, for instance, in a machine controller. General notes on Type VF5.. Description VF5.. • Signal input for a NORIS standard frequency signal Input signal The NORIS standard signal corresponds to a rectangular voltage with • Suitable to evaluate sensors of the FT.. and FA.. series an amplitude that corresponds to • Input range: 0 ... 10.000 Hz (according to type) the operating voltage applied. This • Maximum range frequency between: 50 ... 100 Hz (VF500..), results in a signal that is immune to interference and tolerates consider- (Factory-set frequency adjustment) able changes in the operating volt- To avoid triggering errors the frequency full range set in factory must be the highest frequency of the measuring chaine. age. The operating voltage required by the sensor is provided by the measuring transducer. Electric isolation The operating voltage and sensor input are electrically isolated from the output signal. Therefore, multiple operation of amplifiers and evaluation devices is possible at the same operating voltage and from only one sensor. Operating status display by LED The green LED will be lit when the operating voltage is applied and the device is working normally. Output signal The output signal generated is a standardized voltage of 0 ... 10 V/DC or 2 ... 10 V/DC or, respectively, a standardized current of 0 ... 20 mA or 4 ... 20 mA. The output signal follows the input signal strictly linearly (deviation < 0.1%). The output signal can be used to supply additional devices, such as indicating instruments and limit-value switches. Attention should be paid to the maximum driver ca
カタログの1ページ目を開く
Other Data Type key / variants LED code x = LED lighting - = LED out o= LED flashing OPerating x Frequency version: Please state upper range frequency in case of order Device codes (10 V/DC or 20 mA meets the ordered input frequency) - ... Maximum range frequency in Hz (= 20 mA or 10 V) Measuring transducer Input signal F Frequency input for NORIS standard signal (sensor series FT / FA) Type series 5 Type 5 Input range fB / upper-range frequency fE Maximum range frequency
カタログの2ページ目を開くNORIS Group GmbHのすべてのカタログとパンフレット
-
Unique Yacht Automation
16 ページ
-
Datasheet TAV131
3 ページ
-
Datenblatt VFS5
2 ページ
-
Datasheet PAx9
6 ページ
-
Datasheet RG5
2 ページ
-
Datasheet VFW5
2 ページ
-
Datasheet RP5, RPT5
2 ページ
-
Datasheet NIR3 NIQ3
20 ページ
-
Datasheet VD61
6 ページ
-
Datasheet FA13
14 ページ
-
Datasheet NIQ31
16 ページ
-
NORIS Marine Overview
13 ページ
-
Datasheet FA54
11 ページ
-
NORIS Brochure
15 ページ
-
Datasheet TP31 TH31
5 ページ
-
Datasheet EOT
6 ページ
-
Datasheet DWA
4 ページ
-
Datasheet TP23
4 ページ
-
Flyer NORISYS 4 CPU
2 ページ
-
Datasheet RFW5
2 ページ
-
Datasheet RTK5
2 ページ
-
Datasheet RFJ5
2 ページ
-
Datasheet VTK5
2 ページ
-
Datasheet RF5
2 ページ
-
Datasheet RI5
2 ページ
-
Datasheet RFG5
2 ページ
-
Datasheet VPT5
2 ページ
-
Datasheet RH5
2 ページ
-
Datasheet VFS5
2 ページ
-
Datasheet RH41M
2 ページ
-
Datasheet RW5
2 ページ
-
Datasheet VMP70
3 ページ
-
Datasheet VP5
2 ページ
-
Datasheet NADS3
2 ページ
-
Datasheet NAD2
2 ページ
-
Datasheet NAD1
2 ページ
-
Flyer NORISYS 4
2 ページ
カタログアーカイブ
-
Datasheet GE12
2 ページ
-
Datasheet GE14
2 ページ