Limit-value switch, input DC-voltage 1 Straightforward application Suitable for severe operating conditions Compact construction Galvanic isolation of the input and Anti-tamper seal for drum scale Limit value freely adjustable by drum scale output signal to the supply voltage • Limit-value switches Meet high EMC-requirements requirements Volt-free output as change over switch contact or make-contact Open-circuit or closed-circuit variants available Test function to simulate an increased sensor signal without critical machine loading (RG5...-S) • Latching function of output relay (RG5...-S) Short circuit and broken-wire monitoring with live-zero signals Operating characteristics displayed by integrated LEDs Flame-inhibiting and self-extinguishing body Limit-value switches of series 5 Limit value switches of the series 5 are designed to monitor and process electric measured variables. Working principle: When the actual value of the measuring signal supplied reaches the setpoint, the built-in relay will operate. The switching status of the relay contact may, for instance, be monitored or individually processed by a machine controller. General notes on Type RG5.. Description RG5.. • Designed to monitor a direct current In the open-circuit variant, the output relay pulls up when the • Devices from 0 ... 10 V/DC without live-zero-monitoring limit-value is exceeded with the supply voltage applied. Failure of the • Devices from 2 ... 10 V/DC with live-zero-monitoring voltage will not result in any switching function below the limit value. • Limit value settings possible over complete input range by means of drum scale Test function for open circuit devices The Typ RG51-S have the integrated special functions testing and Integrity and short-circuit monitoring of input signal latching. The testing function offers while the contacts 2 and 5 are con- The integrated signal monitoring of the live-zero device provides nected, the limit-value signal selected on the drum scale is lowered by monitoring of the sensor signal for broken wire and short circuit. If about 15%. In a speed monitoring application, this means that an over- the measured signal falls below the limit at approx. 1 V, the relay will speed condition can be simulated within the normal range without running operate. The red LED will light up and the green LED will be flashing. the machine in the critical range. Limit-value switches with 0 ... 10 V/DC input are not available with broken-wire and short-circuit alarm of the sensor circuit. Latching function for open circuit devices Open circuit devices can optionally be equipped with a latching Volt-free relay contact, closed-circuit or open-circuit version A volt-free relay contact is provided as a change over switch contact for outputting and further processing. In addition, there is a function (see type code). When the limit value is exceeded, the relay keeps activated even if the signal falls below the limit value afterwards. The device has to be reset by disconnecting the supply voltage. choice between closed-circuit and open-circuit devices. In the case of closed-circuit devices, the output relay is pulled up in the normal state of operation with the supply voltage applied. It drops off upon the limit-value being exceeded o
カタログの1ページ目を開く
Technical Data Series RG5.., RG5..-S Supply voltage Reverse voltage protection Integrated 2.5 times UR up to 2 ms Voltage drops Galvanic isolation Between input signal and supply voltage Power consumption Input signal Input resistance Output contact Volt-free change over switch contact, closed circuit or open circuit (RG5..) Volt-free NOC, closed circuit or open circuit (RG5..-S) Maximal switching capacity Limit value Adjustable on tamper-proof drum scale between 0 ... 10 V/DC for RG51.., 2 ... 10 V/DC for RG52.. Test function Connect 2/5 to lower limit value approx. 15% (only RG5..-S)...
カタログの2ページ目を開くNORIS Group GmbHのすべてのカタログとパンフレット
-
Unique Yacht Automation
16 ページ
-
Datasheet TAV131
3 ページ
-
Datenblatt VFS5
2 ページ
-
Datasheet PAx9
6 ページ
-
Datasheet VFW5
2 ページ
-
Datasheet RP5, RPT5
2 ページ
-
Datasheet NIR3 NIQ3
20 ページ
-
Datasheet VD61
6 ページ
-
Datasheet FA13
14 ページ
-
Datasheet NIQ31
16 ページ
-
NORIS Marine Overview
13 ページ
-
Datasheet FA54
11 ページ
-
NORIS Brochure
15 ページ
-
Datasheet TP31 TH31
5 ページ
-
Datasheet EOT
6 ページ
-
Datasheet DWA
4 ページ
-
Datasheet TP23
4 ページ
-
Datasheet VF5
2 ページ
-
Flyer NORISYS 4 CPU
2 ページ
-
Datasheet RFW5
2 ページ
-
Datasheet RTK5
2 ページ
-
Datasheet RFJ5
2 ページ
-
Datasheet VTK5
2 ページ
-
Datasheet RF5
2 ページ
-
Datasheet RI5
2 ページ
-
Datasheet RFG5
2 ページ
-
Datasheet VPT5
2 ページ
-
Datasheet RH5
2 ページ
-
Datasheet VFS5
2 ページ
-
Datasheet RH41M
2 ページ
-
Datasheet RW5
2 ページ
-
Datasheet VMP70
3 ページ
-
Datasheet VP5
2 ページ
-
Datasheet NADS3
2 ページ
-
Datasheet NAD2
2 ページ
-
Datasheet NAD1
2 ページ
-
Flyer NORISYS 4
2 ページ
カタログアーカイブ
-
Datasheet GE12
2 ページ
-
Datasheet GE14
2 ページ